R160 / Multi Jet Brass Body Dry Type Water Meter

Min.Order: 5,000
Product origin: Taizhou, Zhejiang, China
Infringement complaint: complaintComplaint
US$ -1

Description

Product Description

Multi jet ,dry dial, direct reading. 
Producted in the versions for cold water 30ºC.
Long durability and elevaated precisions guaranteed.


Characteristics:
All the Materials in contact with water, consciously selected by the known resistance to corrosion;
Cold water meter under current standard for lower than 30ºC(T30), but  the type meter can be used safely in water temperature up to 50ºC(T50);
The ROTARYindicator register for the most comfortable reading position of 5 Rollers (Dn40 with 6 Rollers) and 4 Pointers;
The Impeller is the only moving parts in contact with water permitting the most reliable;
The extra inlet filter at the inlet of the meter body permits cleaning it without breaking the metrological seal;
The conception of the Magnetic Protection to against the external influences;


Maximum permissible error:
From the minimum flow-rate (q1)inclusive to the lower zone of the transitionalflow-rate (q2) exclusive: ± 5%.
From the transitional flow-rate (q2) inclusive to the higher zone of the maximum flow-rate (q4) exclusive: ± 2%
(hot water meter± 3%. )  
Technical Features 
Model NumberLXSG-15E5LXSG-20E5LXSG-25E5LXSG-32E5LXSG-40E5
Nominal diameter (DN)[mm]:1520253240
Ratio Q3/Q1: R80R100160R80R100160R80R100160R80R100160R80R100160
Overload flow rate (Q4) [m³/h]3.1253.1253.1255557.8757.8757.87512.512.512.5202020
Permanent flow rate (Q3) [m³/h]2.52.52.54446.36.36.3101010161616
Transitional flow rate (Q2) [m³/h]0.050.040.0250.080.0640.040.1260.10080.0630.20.130.10.320.2560.16
Minimum flow rate (Q1) [m³/h]0.031250.0250.01560.050.040.0250.078750.0630.03930.1250.10.06250.20.160.1
Ratio Q2/Q1:1.6
Ratio Q4/Q3:1.25
Accuracy class:2
Maximum permissible error for the lower flow rate zone (MPEι):±5%
Maximum permissible error for the upper flow rate zone (MPEμ):±2% water temperature30ºC                                                                                                                                                                                                    ±3%  water temperature >30ºC
Temperature class:T30 and T50
Water pressure classes:MAP 16
Pressure-loss classes:P63
Indicating range[m3]:99 999
Resolution of the indicating device[m3]:0.00005
Flow profile sensitivity classes:U0 D0
Orientation limitation:H
Length L[mm]:165/190190260260300
Connection type-Screw thread size:G3/4BG1BG 1 1/4BG 1 1/2BG2B