600V Tracking Testing Machine for IEC60884

Min.Order: 1
Product origin: Guangzhou, Guangdong, China
Infringement complaint: complaintComplaint
US$ 4700 ~ 4900

Description
Tracking Lab Testing Equipment

Product details: Model ZLT-LDQ:

The ZLT Tracking Tester is used for the determination of comparative tracking indices of solid electrical insulating materials on pieces taken from parts of electrical and electronic equipment and on plaques of material using alternating voltages.

The ZLT Tracking Tester is a fully automatic instrument contained in its own cabinet to maximize the safety of the operator. Inside the well lit cabinet, a test specimen is placed on a glass plate and two platinum electrodes are lowered onto the top surface. A gauge block is supplied with the instrument to ensure the electrodes have the proper distance between them. The table height is easily adjustable to ensure the proper angle of the electrodes and height of drops. The rest of the test is controlled from outside the test chamber with the door closed. The voltage, limiting current, drip rate and number of drips are all set on the control panel. An operator should observe the test to see if a flame ignites. The instrument sounds an alarm if there is a tracking failure of at least two seconds.

Platinum is specified as a material for the electrodes. The power supply unit is designed for voltages up to 600 V, or up to 1000V. An electronic control unit serves for releasing the drops.
In the case of the ZLT tracking tester, the electrode arrangement is mounted in a stainless steel cabinet. By a glass door, a good accessability of the testing arrangement ensurws a pleasant working. A safety system breaks the supply when the cabinet is opened.

Volume of chamber 0, 1 m3, model: ZLT-LDQ1
Volume of chamber 0, 5 m3, model: ZLT-LDQ2
Includes:
1 set of platinum electrodes 99% minimum purity,
1 bottle of ammonium chloride 99, 8% purity,
1 glass Platform,
1 scale, 4 mm,
Power Supply
220 V 50 Hz, other voltage request
Power Consumption
650VA
Test Voltage
100~600V continuonsly adjustable, displayed value: r. m. s
Test Current
Current limiting 1A± 0, 1A adjustable, displayed value: r. m. s, tolerance of 1, 5%
Electrode Dimensions
width: 5mm± 0, 1mm, thickness: 2mm± 0, 1mm, length > 12mm, one end chisel-edge angle : 30° ± 2° , platinum with a purity of 99%
Electrode Pressure
Pressure force exerted on the specimen by each electrode 1 N, distance between electrodes adjustable
Dripping Nozzle
outer diameter: 0, 9mm~1.2mm for solution A
0, 9mm~3, 45mm for solution B
Dripping Interval
0-99 seconds (adjustable), the time for 50 drops to fall on the specimen shall be (24, 5± 2)min
Height Drops
35mm± 5mm
Dripping Weight
The mass of a sequence of 50 drops shall lie between 0.997g and 1.147g
The mass of a sequence of 20 drops shall lie between 0.380g and 0.480g
Specimen Support Platform
Thickness≥ 4mm glass
Volume Of Chamber
> 0.5m³ (or 0, 1 m³ ), black interior
Outer Dimensions
W*D*H=1100mm*550mm*1100mm
Conform to standard
IEC60112, IEC60335-1, IEC60598-1, IEC60884-1