Feature and Description:
1. High Accuracy: Using grating micrometer level precision screw drive to ensure the accuracy of wavelength <±0.3nm;Transmittance of accuracy reaches ±0.3%.
2. Convenience for use: 5.7 inch graphic LCD display. Spectrum curve be clear at a glance and easy to operate. There isquantitative analysis,qualitative analysis, kinetics test, DNA/RNA, multi- wavelength analysis in special purpose testing program.
3. Service life durable: Imported Halogen lamp ensures the light source for up two years of life, receiver life for 20 years.
4. Wide application fields: Optional Equipped with Peltier/sipper unit, with Micro cell holder, with (5°incident angle) Reflectance measurement attachment etc. expands the application areas of more.
•Usage and Application
1.Photometric measurement: Convenience to measure samples in the specified wavelength absorbance and transmittance.
Multi-wavelength detector is maximum simultaneous determination of 10 wavelengths.
2.Quantitative measurement: Establish automatically standard curve.
first after we order the third order curve fitting. Optional method: Single wavelength calibration,Double wavelength calibration,
Three point method,
3.Qualitative measurement: Including scaling, smoothing, filtering, detecting peak-valley etc.
4.Kinetics measurement: Calculate kinetics of enzyme reaction rate. There are scaling, smoothing, filtering, detecting peak-valley
and finding the derivative in a variety of graph processing methods for your choice.
5.DNA/RNA,Test function of protein calculates automatically the sample ratio and concentration.
Model | NU-T1810 | ||
Optical System | Split beam, Littrow,Grating 1200 line/mm | ||
Wavelength Range | 190~1100nm | ||
Spectral Bandwidth | 1.8nm | ||
Wavelength Accuracy | ±0.3nm | ||
Wavelength Repeatability | ±0.1nm | ||
Photometric Accuracy | ±0.3%T;±0.002Abs(0~0.5Abs);±0.004(0.5-1.0Abs); | ||
Photometric Repeatability | ±0.1%T;±0.001Abs(0~0.5Abs);±0.002(0.5-1.0Abs); | ||
Stray Light | ≤0.05%T, @220nm/360nm | ||
Noise Level | ±0.0015Abs | ||
Stability | ±0.0015A/h@500nm | ||
Baseline Flatness | ±0.0015Abs | ||
Baseline Dark Noise | 0.1%T | ||
Photometric Range | 0~200%T,-4~4A,0~9999C(0-9999F) | ||
Light Source | Tungsten Lamp(Pre-aligned) | ||
Scan Speed | Hi,MED.,LOW.,MAX.3600nm/min | ||
Display | 320×240 Dots Array Graphic LCD | ||
System Language | English | ||
Output | USB1.1 Connecting to computer&Parallel port for printer | ||
Power Requirement | AC90~250V/ 50~60Hz | ||
Dimensions(L×W×H) | 550×400×210 | ||
Weight | 19kg |