Shanghai Gn Electronic Water Pressure Control Switch

Min.Order: 1
Product origin: Shanghai, China
Infringement complaint: complaintComplaint
US$ 159

Description
Brief introduction
1. This model intelligent pressure switch is a kind of intelligent digital pressure control products
2. It integrate pressure measurement, LED display and control.
3. It is complete electronic structure, the former adopt pressure sensor which is diaphragm, oil fulfill and piezoresistive type.
4. Application: Measure the gas and liquid. Suit for pump control, tank monitoring, level control, filter plug, monitoring, leakage monitoring. Also it widely used in hydraulic and pneumatic situation, like mechanical facility and process control.

Main features
1.4 digits display the current pressure value, pressure preset switch point and delay switch output.
2. Switch signal can be set it randomly between zero and full scale. The housing have LEB with node action.
3. Easy to observing key-press calibration and the parameter's setting in field. Convenient operation. The overload capacity is 1.2A for 2 channels switch signal output.
4. Analog output (4-20Ma), the measurement range: 0-600bar (Option)
Most Accurate Control By Electronic Thermal Mass Water Flow Switch
                                    -----------We are gold supplier in 9 consecutive years
    CX-FS series Electronic thermal mass  flow switch , also known as differential thermal flow sensor and Thermal flow sensor . The set range can be 1-20m/s . Have relay output (230VAC.4A). Suitable for different kinds fluid .Concise and direct indicator ,and with high reliable .
    The Principle of electronic thermal mass flow switch based on the principle of thermal theory, there are two resistances in the closed probe . One resistance was heated and regarded as detected resistance , the other one was heated and regarded as standard resistance . When the medium is flowing ,the heat on the heated resistance will be taken away and the resistances' value will be changed . The differential resistances value is the basis of determining the flow velocity .




Application:
gaseous /liquid
The flow switch for ground-source heat-pump is mainly applicable to industrial automation/mechanical equipment/air compressing industry/ refrigeration and air-conditioner. The magnet not contact with flowing water, so can normally work in sewage discharging system.

CX-FS-FB Paddle Flow Switch
DiameterDN25…DN150
Set range20…1800L/min(water)
Repeatability±2.5%FS
Connectionterminal type
OutputMechanical switch  NO+NC(250VAC,3A)
Pressure proof16 bar
Average pressure loss:0.08bar( at max.flow rate)
Ambient temperature-25…80C
Medium temperature0…90C
Interface screwG1"pipe screw
Protective classIP33
Weight0.55kg
MaterialMain bodystainless steel
Process connection:brass
Connection rodbrass
Bafflestainless steel
Seal NBR
HousingABS

CX-FS-FB12 Baffle Flow Switch
Repeatability±2.5%FS
Connectionterminal type
OutputMechanical switch  NO+NC(250VAC,3A)
Pressure proof16 bar
Average pressure loss:0.08bar( at max.flow rate)
Ambient temperature-25…80ºC
Medium temperature0…90ºC
Interface screwG1"pipe screw
Protective classIP33
Weight0.85kg
MaterialMain bodystainless steel
Process connection:brass
Connection rodbrass
Bafflebrass
SealNBR
HousingABS

CX-FS-FPD20 Pointer display type piston flow switch
Mediumliquid or gas
Repeatability≤±3%full scale
Pressure200bar(stainless steel type)100bar(brass type)
Outputnormally open output
Contact capacity240VAC / 110VDC 1.5A
Ambient temperature-20…70ºC
Medium temperature0…70ºC
ProtectionIP65
OutletM12*1
MaterialElectronic bodyPC
Switch bodystainless steel / brass nickel plating
Springstainless steel

CX-FS-FR11 Electronic Flow Sensor
Set range1…150cm/s( water),3…300cm/s(oil),20…2000cm/s(air)
OutputPNP, NPN, Relay ,4-20mA, NO+NC (SPDT)
Power supply24V±20%DC or 230V±15%AC
Switching CurrentMax.400mA(PNP or NPN type ), Max.4A( Relay type )
Unload currentMax.80mA
Flow indicatorLED (6)
Set typepotentiometer set
Proof Pressure range100bar
Temperature gradient4ºC/s
Response time1--13s,standard is 2s
Initialization time8s
Electrical protectionreversed-phase ,short circuit ,overload protection
Protection classIP67
Medium temperature20--80ºC
Environment temperature-20--80ºC
Storage temperature-20--100ºC
ConnectionM12 connector /2m cable (option)
MaterialProbe is stainless steel . Housing is PBT
Weight0.4kg
 
CX-FR-FR12 Electronic flow switch
Set range1…150cm/s( water),3…300cm/s(oil),20…2000cm/s(air)
OutputPNP, NPN, Relay ,4-20mA, NO+NC (SPDT)
Power supply24V±20%DC
Switching CurrentMax.400mA(PNP or NPN type ), Max.4A( Relay type )
Unload currentMax.80mA
Flow indicatorLED (6)
Set typepotentiometer set
Proof Pressure range100bar
Temperature gradient4ºC/s
Response time1--13s,standard is 2s
Initialization time8s
Electrical protectionreversed-phase ,short circuit ,overload protection
Protection classIP67
Medium temperature20--80ºC
Environment temperature-20--80ºC
Storage temperature-20--100ºC
ConnectionM12 connector /2m cable (option)
MaterialProbe is stainless steel . Housing is PBT
 
ModelConnectionNotesAccuracy
HFS-251″-11½NPT ScrewRed Case5%
HFS-20¾″-14NPT Screw
HFS-15½″-14NPT Screw
JYF-251″-11½NPT ScrewWhite Case2-3%
JYF-20¾″-14NPT Screw
JYF-15½″-14NPT Screw
Rated Voltage?Rated AmpsA.C.125~250VPower(Cosmp.) 
Non-inductive Current12A1 
Full Load12A0.75 
Locked Roter72A0.45 
Required Flow for actuating switch (m3/h) 
Pipe size (in)11-¼1-½22-½34568 
Min.
Flow
Flow lower,1-2 closed11.31.73.14.16.28.412.916.846.6 
Flow lower,1-3 closed0.60.81.12.22.84.36.19.312.338.6 
Max.
Flow
Flow lower,1-2 closed234.46.67.81218.426.832.794.2 
Flow lower,1-3 closed1.92.84.16.17.311.417.325.230.790.8 
 
   
   
   
   
   
   
   
   
   
   
 
Scale numberScaleDead zoneSwitching frequencySensor material
GK022-0-2KPa30Pa10times/sec316L
GK1010-0-10KPa0.2KPa10times/sec316L
KK022-0-2KPa30Pa10times/secDing Qing rubber
KK1010-0-10KPa0.2KPa10times/secDing Qing rubber
Product Tag:
Related categories:
Scroll to Top