1kw 5 Kw off Grid Hybrid Home PV Inverter Battery Bank Product Energy Solar Panel Solar Power System

Min.Order: 1
Product origin: Jinhua, Zhejiang, China
Infringement complaint: complaintComplaint
US$ 300 ~ 5000

Description

Connecting Diagram


Configuration List


ItemCertificationDescriptionQ'tyWarranty
Solar panelTUV / IEC / ECMono or Poly8 pcs20 years
InverterCGC / CQC / VDEOne (MPPT) tracking/ one phase 220V, 2000W/ SM-SH20001 set5 years
Distribution box (Optional)CELighting Protection. Air switch, Fusegar, knife switch,1 set5 years
Mounting systemCESlant roof bracket/ Cement Ground bracket/ Soil ground bracket1set10 years
PV cableTUV/ ULDC port PV1-F20m10 years
AC port YJV-3$4mm25m10 year


Solar Panel


TypeMONOPOLY
Power class280W335W270W320W
Open Circuit Voltage (Voc)38.19.3638.145.8
Short Circuit Voltage (Isc)9.27469.239.15
Max power Voltage (Vmp)8.848.7631.137.2
Max Power Current (Imp)8.848.768.698.61
Efficiency≥17.1%≥17.2%≥16.5%≥16.4%
Dimension (mm)1650x991x351960x991x351650x991x351960x991x35z
Weight (kg)18±5%22.5±5%18±5%22.5±5%
 
Solar Inverter


Ambient temperature range-25~+60ºC(>45ºC deloading)
Relative humidity0~95%
Max operating altitude4000m (>3000m derating)
Protection degreeIP65
TopologyTransformerless
Night power consumption (W)<1
Cooiong methodNatural convection
Noise emision (dB)<25
DisplayLCD
Warranty (Year)5/10/15/20/25 (Optional) Years
 
Solar Controller


Rated Charge current(A)40A
Rated DC voltage(V)24/48 automatic identification
Solar input  Max voltage(V)42/84
BatteryOver charge protective voltage(V)28.6/57.2
BatteryOver charge recover voltage(V)27.4/54.8
BatteryConstant charge voltage(V)27/54
BatteryOver discharge alarm voltage(V)20/40
Environment Humidity  and temperature0-90%  No condense,55ºC
Protective FunctionsProtection against anti-charge at night,
battery over charge, over discharge protection,
Joint-reversed of solar modules

 
PV Combiner Box



 
ComponentsParameterFunction
Circuit breaker (Air switch)16AWhen the current of the protected circuit exceeds the specified value, 
the circuit breaker will  automatically break off to protect the whole circuit.
Fusegear16AWhen the current of the protected circuit exceeds the specified value, 
fusegear will break off automatically
Surge protective  device (SPD)UC:420V lmax:20KA; In: 10KAUp≤1.8KVPhotovoltaic lightning protection device
One phase self dual over voltage protection deviceWorking range 220V,50Hz, over voltage protection
Uvo=270V±5V 
Under voltage protection 
Uoe= 170±5V 
When the circuit voltage is highet or  lower, it will shut down automatically. 
when the voltage reaches standard level, it will recover automatically.
Knife switch/automatic/ by hand
 


ConductorTinned Fine Re Copper Strand, according to VDE0295/IEC60228. Class 5
InsulationPolyolefin Copolymer electron-beam coss-linked
Sheath JacketPolyolefin Copolymer electron-beam coss-linked
Nominal VoltageUo/U=600V/1000VAC, 1000V/1800VDC
Test  Voltage6500V, 50Hz, 5Min
Temperature Rating-40°C-125°C ,More than 25 Years  (TUV)
Fire PerformanceIEC 60332-1
Smoke EmissionIEC61034, EN 50286-2
Low Fire LoadDIN 51 900
CertificationTUV 2PFG 1169/08 2007 PV1--F
 
Mounging System


The wind capacity of such mounting system can reach (40m/s, 32.5kg/ square meters, level 13), snow load capacity can reach 70kg/ square eters

The whole system has strong safety performance.

Can be customized based on customer's cactual situation

The mounting system can be desingned with best solution based on slope roof, flat ground and soil ground

 










 

 

 

 