2023 4rt to 85rt R410A Refrigerant Rooftop Package Air Conditioning

Min.Order: 1
Product origin: Shanghai, China
Infringement complaint: complaintComplaint
US$ 19400 ~ 19435

Description
Shenglin4RT to 85RT R410A refrigerant rooftop package air conditioning            






Rooftop air conditioner
Features
Description:
1. Air cooled rooftop air conditioner.
2. Cooling capacity: 8kw to 90kw, a variety of choices.
3. High external pressure.
4. Applicable to residential and commercial buildings, hotels, and scientific research units, factories and enterprises and so on.

Feature:
1. Evaporator: Type Inner grooved copper tube and aluminum fin
2. Fin Type 5* :Slotted fin hydrophilic aluminum fin
3. Condenser: Type Inner grooved copper tube and aluminum fin
4. Fin Type 5* :Rippled hydrophilic aluminum fin
5. Condenser Fan Type: Low noise axial type



Technical Data
  SL-WKR Series-Roof Top AH Specifiaction 1
Model   GT-WKR-10151820253035
SpecificationCooling capacity 1*kW10.515.018.521.026.329.835.0
Heating capacity 2*kW11.515.919.522.127.632.637.1
Supply air 3*m3/h1800240029003500450050005800
Static pressure 3*Pa100150150180200250250
Noise 4*dB(A)60606262656568
Power3N-380V-60Hz
Total capacity3.95.747.08.279.9611.014.15
ColorWhite
ooling systemCompressorTypeEfficient scroll closed 
Quantity1111112
Supply air fanTypeLow noise centrifugal type
CapacitykW0.370.550.750.751.11.52.2
EvaporatorTypeInner grooved copper tube and aluminum fin
Fin type 5*Slotted fin hydrophilic aluminum fin
CondenserTypeInner grooved copper tube and aluminum fin
Fin type 5*Rippled hydrophilic aluminum fin
Condenser fanTypeLow noise axial type
Quantity1111112
RefrigerantRefrigerantR22/R407C
Refrigerant controlExternal balance type thermal expansion valve
Air filterInitially effect plate filter
DimensionsLmm1400140016001600185018502200
Wmm1050105012001200140014001800
Hmm1050105010501050120012001520
Weightkg200230260300550600850
  1.   Cooling condition: Indoor dry bulb/wet bulb:29/19ºC,Outdoor dry bulb/wet bulb:46/24ºC
  2.   Heating condition:Indoor dry bulb/wet bulb:20/-ºC;outdoor dry bulb/wet bulb:7/6ºC;
  3.   The air volume and static pressure`s specification in the table is standard, and can be designable.
  4.  Noise data is measured in the front of the units when cooling under the standard air volume.
  5.  Fin type and material can be designable. 
  SL-WKR Series-Roof Top AH Specifiaction 1
Model   GT-WKR-4050607090110120
SpecificationCooling capacity 1*kW42.052.861.270.287.5105.1122.5
Heating capacity  2*kW44.155.462.573.892.8112.0130.0
Supply air 3*m3/h700086001000012000145001700020000
Static pressure 3*Pa300300300350350400400
Noise 4*dB(A)68696970717272
Power3N-380V-60Hz
Total capacity17.2420.7223.029.7639.144.6651.58
ColorWhite
ooling systemCompressorTypeEfficient scroll closed
Quantity2222244
Supply air fanTypeLow noise centrifugal type
CapacitykW2.23445.57.57.5
EvaporatorTypeInner grooved copper tube and aluminum fin
Fin type 5*Slotted fin hydrophilic aluminum fin
CondenserTypeInner grooved copper tube and aluminum fin
Fin type 5*Rippled hydrophilic aluminum fin
Condenser fanTypeLow noise axial type
Quantity2224444
RefrigerantRefrigerantR22/R407C
Refrigerant controlExternal balance type thermal expansion valve
Air filterInitially effect plate filter
DimensionsLmm2200260026003200320060006000
Wmm1800220022002200220023002300
Hmm1520170017001900190023002300
Weightkg850110012501400165018502200

Note:
1. Cooling condition: Indoor dry bulb/wet bulb:29/19ºC,Outdoor dry bulb/wet bulb:46/24ºC
2. Heating condition:Indoor dry bulb/wet bulb:20/-ºC;outdoor dry bulb/wet bulb:7/6ºC;
3. The air volume and static pressure`s specification in the table is standard, and can be designable.
4. Noise data is measured in the front of the units when cooling under the standard air volume.






 
Note: for further information please send me email.