Gpa, Gpax, Gpar High-Reliability Current Transducer

Min.Order: 2
Product origin: Jiaxing, Zhejiang, China
Infringement complaint: complaintComplaint
US$ -1

Description
                            Gpa,GPAX,GPAR High-Reliability Current Transducer
1. Summarize:

Electric quantity transducer is a measuring instrument that it makes measurand electric quantity (AC Current/Voltage Active  Power Reactive Power Active Energy Reactive  Energy Power Line Frequency.Phase Angle Power Factor DC Current/Voltage) turn into DC current or voltage output that accroding to proportional linearity . It widely applied to electric measurement autocontrol and system altitude that in electric power Coal metallurgy railway and so on.

Applied Standards & Rules
       Measuring and conversion IEC 688 / 1992 - 04
       Dielectrical strength IEC 688 2KVac / 1 min.
      Surge and Impulse test ANSI C37.90 / 1989
      IEC 255-3 (1989) 4KV 1.2 x 50 us


      Current transducers convert AC input into load independent DC current & voltage output signal. This signal is highly accurate & proportionally linear to the AC input. GPA versions convert the AC sinusoidal waveforms to linear DC output calibrated to the RMS value.

2.Models:
      GPA         single phase current
      GPAS       single phase self-powered current
      GPA2       2 wires / 4~20mA ( 8~36V DC powered )
      GPAX       three phase current
      GPAXS    three phase self-powered current
      GPAX2    2 wires / 4~20mA ( 8~36V DC powered )
      GPAR      single phase TRMS current

The following models can be used with each other:
     EPA         single phase current
      EPAS       single phase self-powered current
      EPA2       2 wires / 4~20mA ( 8~36V DC powered )
      EPAX       three phase current
      EPAXS    three phase self-powered current
      EPAX2    2 wires / 4~20mA ( 8~36V DC powered )
      EPAR      single phase TRMS current


3.Technical Specifications:


3.Models&Specifications


4.Terminal Connection


5.Dimensional Drawings






Technical Specification  
 
Reference Standard   
 
GB/T 13850-1998(IEC688-1992) 
 
Accuracy 
Long Term stability ≤±0.5%/year.No accumulation error
Temperature influence≤ 100ppm/oC
Response Time
 
  <400ms
 
Output Ripple<1.0%(peak-peak value)
 
Input burdenCurrent less 0.2VA;voltage less 0.1VA
 
 Frequency Nominal frequency ±10%
 
Maximum output loadCurrent output Max10V pressure drop
 
 Auxiliary power Ratedvoltage80%-120%,rated current 90%-110% 
Auxiliary load effect 
 
 <± 0.2% 
 
Allow excessive input Current 2rate continuous 10rate 20 secs voltageMax 2ratecontinuous 
 
Dielectric strengthInput /output /power/between the crust 2KV AC 1 minIEC866 
 
Impact testANSIC37.90a/1973,IEC255-4 (5kV1.2/50us PulsedVoltage) 
Calibration amplitudeFull scale least±3%,zero least±1%
 
Magnetic field effect0.4KA/m magnetic field strength change <0.05%
 
Operating condition Temperature -10~55oC relative humidity≤95%RHnoncondensing 
Storage condition Temperature -40~70oC relative humidity ≤95% RHnoncondensing 
 
Haiyan Jinhan Electronic Technology CO.,LTD

The model of this series is shown in the following table :
ProductModel No.Swap model
AC current transducer(1 unit of avg. to rms conversion)GPAEPA
AC current transducer(1 unit of avg. to rms conversion)GPVEPV
AC current transducer( 2 wires / 4~20mA ( 8~36V DC powered)GPA2EPA2
AC current transducer( 2 wires / 4~20mA ( 8~36V DC powered)GPV2EPV2
AC current transducer( 2 wires / 4~20mA ( 8~36V DC powered)GPAX2EPAX2
AC current transducer( 2 wires / 4~20mA ( 8~36V DC powered)GPVX2EPVX2
AC current transducer(1 unit of avg. to rms self-powered)GPASEPAS
AC current transducer(1 unit of avg. to rms self-powered)GPVSEPVS
AC current transducer(3 unit of avg. to rms self-powered)GPAXSEPAXS
AC current transducer(3 unit of avg. to rms self-powered)GPVXSEPVXS
AC current transducer(TRMS conversion )GPAREPAR
AC current transducer(TRMS conversion )GPVREPVR
AC current transducer(2 output)GPATEPAT
AC current transducer(2 output)GPVTEPVT
AC current transducer(3 unit of avg. to rms conversion)GPAXEPAX
AC current transducer(3 unit of avg. to rms conversion)GPVXEPVX
3 phase 3 wire reactive power transducerGPK201EPK201
3 phase 3 wire reactive power transducer(2 output)GPKT201EPKT201
3 phase 3 wire Active power&reactive power transducerGPWK201EPWK201
3 phase 3 wire Active power transducerGPKT201EPKT201
3 phase 3 wire Active power transducer(2 output)GPWT201EPWT201
3 phase 3 wire wate&var&current transducerGPWKA201EPWKA201
3 phase 4 wire reactive power transducerGPK301EPK301
3 phase 4 wire reactive power transducer(2 output)GPKT301EPKT301
3 phase 4 wire Active power&reactive power transducerGPWK301EPWK301
3 phase 4 wire Active power transducerGPKT301EPKT301
3 phase 4 wire Active power transducer(2 output)GPWT301EPWT301
3 phase 4 wire wate&var&current transducerGPWKA301EPWKA301
3 phase 3 wire Active energy transmitterGPWH201EPWH201
3 phase 3 wire Reactive energy transmitterGPKH201EPKH201
3 phase 3 wire Active power+energy transducerGPWWH201EPWWH201
3 phase 3 wire Reactive power+energy transducerGPKKH201EPKKH201
3 phase 4 wire Active energy transduceGPWH301EPWH301
3 phase 4 wire Reactive energy transduceGPKH301EPKH301
3 phase 4 wire  Active power+energy transducerGPWWH301EPWWH301
3 phase 4 wire  Reactive power+energy transducerGPKKH301EPKKH301
Frequency transducerGPFEPF
Power factor transducersGPPFEPPF
Dc isolation transmitterGPDEPD
Dual output dc isolation transmitterGPDTEPDT
Power controllerGPSEPS
 

Share This Story, Choose Your Platform!
Product Tag:
Related categories:
Scroll to Top