Biobase Graphite Furnace Atomizer Atomic Absorption Spectrophotometer for Lab

Min.Order: 1
Product origin: Jinan, Shandong, China
Infringement complaint: complaintComplaint
US$ 8000 ~ 11000

Description

Atomic Absorption Spectrophotometer

Product Description

Features:

Completely controlled by PC, can flexibly select the flame and graphite furnace atomizer (optional).

Integrated floated optical platform design improves the optical system shock resistance stable.

Eight light stands can be changed automatically and preheat the eight lights meantime as well as optimize the working condition of the hollow cathode lamp.

Position adjusting: the flame burner can be set on the best position automatically.

Fully automated wavelength scanning and peak searching.

Complete safety chains protection equipment: warning and automatic safety protection for the wrong burner connection, leakage of the gas, under voltage of air and the abnormal flameout.

Measuring method: flame absorption method and emission method.

Result printing: parameter, data result and diagram.

Data processing: more than 500 data self-storage and cut-off storage, the analyzed result is stored in EXCEL format.

Product Parameters

Model

BK-AA4530F

Wavelength Range

190~900nm

Spectral Bandwidth

0.1, 0.2, 0.4,1.0 and 2.0nm

Wavelength Accuracy

≤±0.15nm

Wavelength Repeatability

0.04nm

Base Line Stability

0.002A/30min (Cu)

Characteristic Concentration

0.02μg/ml/1% (Cu)

Detection Limit

0.004μg/ml (Cu)

Preciseness

0.5%

Grating

1800 lines/mm

Inflamer

All-metal titanium burner

Atomizer

Effective glass atomizer

Lamp Stand

8

D2 background Calibration

When the background is 1 A, the background ability should be deducted not less than 50 times; self absorption background deduction method

Power Supply

220V, 50Hz

Packing Size(W*D*H) mm

860*705*755 (Main instrument); 545*445*1385 (Accessories)

Gross Weight(kg)

105 (Main instrument); 100 (Accessories)

Standard Accessories

Software; Inkjet printer; Oil free Air compressor;

Acetylene reducing valve; Cu Hollow cathode lamp; Air filter

Optional Accessories

Graphite Furnace 4510GF; Hollow cathode lamp(Ag, Au, Ca, Cd, Cr, Fe, Hg, K, Au, Mg, Mn, Na, Ni, Pb, Zn, Sb, etc), Graphite tubes, Recirculating cooling water system, Hydride generator, Autosampler

Flame System:

Acetylene Air Burner

100mm

Ignition Dynamic Baseline Drift

0.006A/30min

Characteristic Concentration

0.025μg/ml/1%(Cu)

Related Standard Deviation of the Accuracy

0.5%(Cu, absorbance>0.8A) (detection limit Cu0.008μg/ml)

Safety System

Can automatically cut off the gas when the pressure is not enough, the power is off, flameout and unconformity of the burner.

Graphite Furnace(Optional):

Max. Temperature

3000°C

Max Heating Speed

≥2000°C/S

Characteristic Quantity

Cd0.5*10T2g Cu0.5*1011g

Accuracy

Cu3% Cd3%

Safety System

Over current protection Low air pressure alarm/protection; Low cooling water flow alarm/protection

Power Supply

220V, 50Hz

Consumption

7000W

Packing Size(W*D*H) mm

740*640*700

Gross Weight(kg)

90

 

 

Mainly Products


 