Mexco Popular Four-Channel Medical Blood Coagulation Analyzer

Min.Order: 1
Product origin: Zhengzhou, Henan, China
Infringement complaint: complaintComplaint
US$ 2000 ~ 3000

Description
Blood Coagulation Analyzer
HP series Blood Coagulation Analyzer adopt photoelectric turbidimetry method, monitor the process of clotting coagulation. Special intelligent software, no influence from pathological sample during the test. Open reagent systems. Micro reagent and sample volume for less use-cost. Timer will start automatically when absorbance is changed, no need of adapter. When test FIB by clauss method, test directly instead of FIB calculating, decreasing theoretical error.

Main Test Iterms:PT, APTT, TT, PT II, V, VII, X, VIII, IX, XI, XII

Models:HP-HEMAC2000A for one channel,
               HP-HEMAC2000B for two channels
               HP-HEMAC2000C for four channels


Main Advantages:
1) LCD screen display.
2) Instrument can automatically start the test procedure once blood samples are added.
3) Results of response curves are displayed during test procedure.
4) A thermo-printer is internally installed to output test results.
5) Wide range test functions including the traditional coagulation methods, CLOT + FIB and the FIB-CLAUSS method.
6) Test results (in terms of units) are given in the form of seconds (S), percentage activities (% Act.), PTR, INR or mg/dl, respectively.
7) Reagents can be universal sources.
8) For the detection of FIB, there are 2 methods: PT-Der and FIB-CLAUSS. Fibrinogen levels are concomitantly available when the PT test is carried out.
9) High precision: The machine applies the light-transmitted turbidimetric principle so that interference of lipemia and jaundice is negligible.
10) The machine provides two incubators for samples and reagents, respectively, which always maintain a precise temperature range at 37 ±0.2
 
Maine parameters
Light sourceLED.
KeyboardA total of 17 key positions are present.
Volume350 x 300 x 150 mm (L x W x H)
Weight5 kgs
Working conditions--Temperature: 10-35 ºC
--Relative humidity: ≤80%
Electric source--220 ±20% voltage
--Frequency: 50Hz
--Power: max. 50VA
Memory system--Programmable details are stored in E2PRAM.
--Main processing procedures are saved in the EPRAM system and micro-controller.
The memory system has a capacity of programming 24 test items (of which 6 items are open), which include the CLOT + FIB and CLAUSS methods. In addition, different units, reference and normal values, standard curves, ISI values etc. are all inclusive in every test item.
Test methods--Coagulation detection is applicable in most test items.
--The CLOT + FIB method can directly give the fibrinogen concentration when PT is being tested.
--The fibrinogen concentration can also be obtained with the CLAUSS method.
Delayed time--One second for PT, TT and FIB, respectively; 10 seconds for APTT and coagulation Factors.
Temperature control:--Thermo-belt heating device.
--A precise temperature range at 37 ±0.2 ºC