Auma Good Quality Explosion-Proof Versions AC

Min.Order: 1
Product origin: Shanghai, China
Infringement complaint: complaintComplaint
US$ 600

Description

Explosion-proof devices must be used in plants where potentially explosive atmospheres are likely to occur. These devices are designed so that they will not act as ignition source. Their constructive measures prevent the occurrence of ignition sparks or hot surfaces.

 

Certification is performed in close collaboration with national and international certification bodies.

 

With the ACExC a control with integral local controls is available for the multi-turn actuators SAEx/SAREx 07.2 - 16.2 and the part-turn actuators SQEx/SQREx 05.2 - 14.2.


 

multi-turn actuators SAEx/SAREx 07.2 - 16.2
the part-turn actuators SQEx/SQREx 05.2 - 14.2.


SEMC is the leading brand of global industry .
You are our very important customer, please do not hesitate to send any question!
     Induction furnace is used for smelting or insulating ferrous metals, non-ferrous metals, sponge iron, such as scrap iron, scrap steel, copper, aluminum and so on. Complete working equipment such as continuous casting machine, rolling mill, mainly used for the production of billet, steel bar, angle steel, H-beam, I-beam, etc. Using KGPS, IGBT, single or double power supply technology, PLC (Siemens) can be realized throughout the monitoring.
 
       Main supply list: 2 sets of electric furnace body, 2 sets of hydraulic or mechanical tilting electric furnace mechanism, 1 set of control platform, 1 set of intermediate frequency control cabinet (6 pulse 1, 12 pulse 2, 24 pulse 4), low voltage control cabinet (6 pulse 1, 12 pulse 2, 24 pulse 4), 1 set of capacitor cabinet, 4 or 8 water-cooled cables; 1 water temperature alarm, 1 leakage alarm; 1 crucible mold, 1 liquid One batch of pressure steel pipe, one set of copper row, three water tanks. Transformer, cooling tower, furnace builder, furnace lining ejector, furnace cover.

 
NO.Electric 
Furnace 
Type
Input 
power
(KW)
input 
voltage
(V)
Input 
current
(A)
Rated 
power
(KW)
DC 
current
(A)
DC 
voltage
(V)
Melting 
rate
(T/H)
working 
frequency
(HZ)
working 
voltage
(V)
cooling water
 pressure(MPA)
Rated 
capacity
(T)
Power 
consumption
(KWH/T)
Power 
Supply
Furnace 
body
1GW-0.25-160/1JJ180380
(6 Pulse)
2561603205000.2410007500.1~0.150.25~0.30.25790
2GW-0.5-250/1JJ280380
(6 Pulse)
4002505005000.4100015000.1~0.150.25~0.30.5770
3GW-0.5-250/1J280380
(6 Pulse)
4002505005000.4100015000.1~0.150.25~0.30.5770
4GW-0.75-400/1JJ400380
(6 Pulse)
6504008005000.6100015000.1~0.150.25~0.30.75770
5GW-0.75-400/1J400380
(6 Pulse)
6504008005000.6100015000.1~0.150.25~0.30.75770
6GW-1-500/1JJ550380
(6 Pulse)
80050010005000.8100015000.1~0.150.25~0.31750
7GW-1-750/1JJ800380/690
(6 Pulse)
1200/
700
7501500/
850
500/
880
0.91000/
500
1500/
2600
0.1~0.150.25~0.31720/660
8GW-1-750/1J800380/690
(6 Pulse)
1200/
700
7501500/
850
500/
880
0.91000/
500
1500/
2600
0.1~0.150.25~0.31720/660
9GW-1.5-1000/0.5JJ1100690
(6 Pulse)
912100011408801.250026000.1~0.150.25~0.31.5700
10GW-1.5-1000/0.5J1100690
(6 Pulse)
912100011408801.250026000.1~0.150.25~0.31.5700
11GW-2-1500/0.5JJ1650690
(6 Pulse)
1360150017008801.750026000.1~0.150.25~0.32675
12GW-2-1500/0.5J1650690
(6 Pulse)
1360150017008801.750026000.1~0.150.25~0.32675
13GW-2-2000/0.5JJ2200690
(6 Pulse)
1400200022758801.950026000.1~0.150.25~0.32650
14GW-3-2500/0.5JJ2750690/950
(6 Pulse)
2275/
1700
25002840/
2080
880/
1250
2.565002600/32000.1~0.150.25~0.33610/560
15GW-3-2500/0.5J2750690/950
(6 Pulse)
2275/
1700
25002840/
2080
880/
1250
2.565002600/32000.1~0.150.25~0.33610/560
16GW-4-3000/0.5J3300690/950
(6 Pulse)
2730/
2040
30003410/
2500
880/
1250
3.25002600/32000.1~0.150.25~0.34610/560
17GW-5-4000/0.5J4400950
(6 Pulse)
2300400033301250550034000.1~0.150.25~0.35600/550
18GW-6-4000/0.5J4400950
(12 Pulse)
2300400033301250550034000.1~0.150.25~0.36600/550
19GW-8-5000/0.5J5000950
(12 Pulse)
34005000420012507~850034000.1~0.150.25~0.38600/550
20GW-10-6000/0.5J6300950
(12 Pulse)
37506000460012508.5~950034000.1~0.150.25~0.310600/550
21GW-12-8000/0.25J8000950
(12 Pulse)
49008000600012509~10.525034000.1~0.150.25~0.312600-550
22GW-15-8000/0.25J8000950
(12 Pulse)
49008000600012509~10.525034000.1~0.150.25~0.315600-550
23GW-15-10000/0.25J10000950
(24 Pulse)
6500100008000125013~1525034000.1~0.150.25~0.315600-550
24GW-18-12000/0.25J12000950
(24 Pulse)
81601200010000120015~1725034000.1~0.150.25~0.318600-550
25GW-20-12000/0.25J12000950
(24 Pulse)
81601200010000120017~1925034000.1~0.150.25~0.320600-550
26GW-25-14000/0.25J14000950
(24 Pulse)
94601400011600120019~21150~20034000.1~0.150.25~0.325600-550
27GW-30-16000/0.2J16000950
(24 Pulse)
108501600013300120021~23150~20034000.1~0.150.25~0.330600-550
28GW-40-20000/0.2J20000950
(24 Pulse)
135452000016600120025~27150~20034000.1~0.150.25~0.340600-550
29GW-50-22000/0.2J22000950
(24 Pulse)
149322200018300120025~28150~20034000.1~0.150.25~0.350600-550


Note:
(1) GW - means medium frequency induction furnace, - 1 - means induction furnace capacity of 1 ton, - 500 - means furnace rated power of 500 KW, / 1 - means furnace operating frequency of 1000 Hz, / 0.5 - means melting furnace frequency of 500 Hz, - J - means hydraulic tilting furnace (furnace shell is steel shell), - JJ - means mechanical tilting furnace. (the shell of the furnace is aluminum alloy).

(2) The above quoted price is for routine configuration. Other configurations can be added, such as leak alarm, water temperature alarm, furnace switch, cover mechanism, lining ejector and transformer, cooling device (open and close cooling tower, closed cooling tower, plate heat exchanger)

3) If necessary, send technicians to carry out the commissioning: the domestic section is free; the overseas section travel expenses, accommodation and food are borne by the user and each person is subsidized 150 US dollars per day.

4) I quote EX-W at a price including simple packing, including shipping charges to Shanghai port area and all inland charges in China.

V) The above electric furnace voltage levels are 380V, 690V and 950/1000V, and the frequency is 50HZ. If the user equipment requirements are different from the above voltage levels and frequencies, each item needs to be increased by 15000USD.

Product Tag:
Related categories:
Scroll to Top