AUMA offers sophisticated control for premium safety requirements with AC 01.2-SIL or ACExC 01.2-SIL actuators controls. SA .2 and SQ .2 actuators combined with these actuator controls can be deployed in safety-related system systems up to SIL 3.
AC 01.2 actuator controls in SIL version are equipped with an additional SIL module designed for the execution of safety functions. In case of an emergency at the plant and when requesting a safety function, the standard logic of AC .2 is by-passed and the safety function is performed via the SIL module. Consequently, the safety function always overrules standard operation.
The highest functional safety level is ensured by the combinations of AC .2 SIL with multi-turn actuators of the SA .2 range or part-turn actuators of the SQ .2 range, certified by TÜV according to IEC 61508 (ed.2). These combinations can be used up to SIL 2 and in redundant version (e.g. 1oo2) even up to SIL 3. The comply with the latest and most demanding issue of IEC 61508 and offer superior flexibility when adapting the safety function within the respective safety instrumented system (SIS).
SA .2 and SQ .2 actuators equipped with these actuator controls have been certified by TÜV Nord. They are suitable for the following safety functions:
Safe STOP up to SIL 2 (single-channel system according to IEC 61508 Ed. 2 |
Safe end position feedback up to SIL 2 according to IEC 61508 Ed. 2 |
NO. | Electric Furnace Type | Input power (KW) | input voltage (V) | Input current (A) | Rated power (KW) | DC current (A) | DC voltage (V) | Melting rate (T/H) | working frequency (HZ) | working voltage (V) | cooling water pressure(MPA) | Rated capacity (T) | Power consumption (KWH/T) | |
Power Supply | Furnace body | |||||||||||||
1 | GW-0.25-160/1JJ | 180 | 380 (6 Pulse) | 256 | 160 | 320 | 500 | 0.24 | 1000 | 750 | 0.1~0.15 | 0.25~0.3 | 0.25 | 790 |
2 | GW-0.5-250/1JJ | 280 | 380 (6 Pulse) | 400 | 250 | 500 | 500 | 0.4 | 1000 | 1500 | 0.1~0.15 | 0.25~0.3 | 0.5 | 770 |
3 | GW-0.5-250/1J | 280 | 380 (6 Pulse) | 400 | 250 | 500 | 500 | 0.4 | 1000 | 1500 | 0.1~0.15 | 0.25~0.3 | 0.5 | 770 |
4 | GW-0.75-400/1JJ | 400 | 380 (6 Pulse) | 650 | 400 | 800 | 500 | 0.6 | 1000 | 1500 | 0.1~0.15 | 0.25~0.3 | 0.75 | 770 |
5 | GW-0.75-400/1J | 400 | 380 (6 Pulse) | 650 | 400 | 800 | 500 | 0.6 | 1000 | 1500 | 0.1~0.15 | 0.25~0.3 | 0.75 | 770 |
6 | GW-1-500/1JJ | 550 | 380 (6 Pulse) | 800 | 500 | 1000 | 500 | 0.8 | 1000 | 1500 | 0.1~0.15 | 0.25~0.3 | 1 | 750 |
7 | GW-1-750/1JJ | 800 | 380/690 (6 Pulse) | 1200/ 700 | 750 | 1500/ 850 | 500/ 880 | 0.9 | 1000/ 500 | 1500/ 2600 | 0.1~0.15 | 0.25~0.3 | 1 | 720/660 |
8 | GW-1-750/1J | 800 | 380/690 (6 Pulse) | 1200/ 700 | 750 | 1500/ 850 | 500/ 880 | 0.9 | 1000/ 500 | 1500/ 2600 | 0.1~0.15 | 0.25~0.3 | 1 | 720/660 |
9 | GW-1.5-1000/0.5JJ | 1100 | 690 (6 Pulse) | 912 | 1000 | 1140 | 880 | 1.2 | 500 | 2600 | 0.1~0.15 | 0.25~0.3 | 1.5 | 700 |
10 | GW-1.5-1000/0.5J | 1100 | 690 (6 Pulse) | 912 | 1000 | 1140 | 880 | 1.2 | 500 | 2600 | 0.1~0.15 | 0.25~0.3 | 1.5 | 700 |
11 | GW-2-1500/0.5JJ | 1650 | 690 (6 Pulse) | 1360 | 1500 | 1700 | 880 | 1.7 | 500 | 2600 | 0.1~0.15 | 0.25~0.3 | 2 | 675 |
12 | GW-2-1500/0.5J | 1650 | 690 (6 Pulse) | 1360 | 1500 | 1700 | 880 | 1.7 | 500 | 2600 | 0.1~0.15 | 0.25~0.3 | 2 | 675 |
13 | GW-2-2000/0.5JJ | 2200 | 690 (6 Pulse) | 1400 | 2000 | 2275 | 880 | 1.9 | 500 | 2600 | 0.1~0.15 | 0.25~0.3 | 2 | 650 |
14 | GW-3-2500/0.5JJ | 2750 | 690/950 (6 Pulse) | 2275/ 1700 | 2500 | 2840/ 2080 | 880/ 1250 | 2.56 | 500 | 2600/3200 | 0.1~0.15 | 0.25~0.3 | 3 | 610/560 |
15 | GW-3-2500/0.5J | 2750 | 690/950 (6 Pulse) | 2275/ 1700 | 2500 | 2840/ 2080 | 880/ 1250 | 2.56 | 500 | 2600/3200 | 0.1~0.15 | 0.25~0.3 | 3 | 610/560 |
16 | GW-4-3000/0.5J | 3300 | 690/950 (6 Pulse) | 2730/ 2040 | 3000 | 3410/ 2500 | 880/ 1250 | 3.2 | 500 | 2600/3200 | 0.1~0.15 | 0.25~0.3 | 4 | 610/560 |
17 | GW-5-4000/0.5J | 4400 | 950 (6 Pulse) | 2300 | 4000 | 3330 | 1250 | 5 | 500 | 3400 | 0.1~0.15 | 0.25~0.3 | 5 | 600/550 |
18 | GW-6-4000/0.5J | 4400 | 950 (12 Pulse) | 2300 | 4000 | 3330 | 1250 | 5 | 500 | 3400 | 0.1~0.15 | 0.25~0.3 | 6 | 600/550 |
19 | GW-8-5000/0.5J | 5000 | 950 (12 Pulse) | 3400 | 5000 | 4200 | 1250 | 7~8 | 500 | 3400 | 0.1~0.15 | 0.25~0.3 | 8 | 600/550 |
20 | GW-10-6000/0.5J | 6300 | 950 (12 Pulse) | 3750 | 6000 | 4600 | 1250 | 8.5~9 | 500 | 3400 | 0.1~0.15 | 0.25~0.3 | 10 | 600/550 |
21 | GW-12-8000/0.25J | 8000 | 950 (12 Pulse) | 4900 | 8000 | 6000 | 1250 | 9~10.5 | 250 | 3400 | 0.1~0.15 | 0.25~0.3 | 12 | 600-550 |
22 | GW-15-8000/0.25J | 8000 | 950 (12 Pulse) | 4900 | 8000 | 6000 | 1250 | 9~10.5 | 250 | 3400 | 0.1~0.15 | 0.25~0.3 | 15 | 600-550 |
23 | GW-15-10000/0.25J | 10000 | 950 (24 Pulse) | 6500 | 10000 | 8000 | 1250 | 13~15 | 250 | 3400 | 0.1~0.15 | 0.25~0.3 | 15 | 600-550 |
24 | GW-18-12000/0.25J | 12000 | 950 (24 Pulse) | 8160 | 12000 | 10000 | 1200 | 15~17 | 250 | 3400 | 0.1~0.15 | 0.25~0.3 | 18 | 600-550 |
25 | GW-20-12000/0.25J | 12000 | 950 (24 Pulse) | 8160 | 12000 | 10000 | 1200 | 17~19 | 250 | 3400 | 0.1~0.15 | 0.25~0.3 | 20 | 600-550 |
26 | GW-25-14000/0.25J | 14000 | 950 (24 Pulse) | 9460 | 14000 | 11600 | 1200 | 19~21 | 150~200 | 3400 | 0.1~0.15 | 0.25~0.3 | 25 | 600-550 |
27 | GW-30-16000/0.2J | 16000 | 950 (24 Pulse) | 10850 | 16000 | 13300 | 1200 | 21~23 | 150~200 | 3400 | 0.1~0.15 | 0.25~0.3 | 30 | 600-550 |
28 | GW-40-20000/0.2J | 20000 | 950 (24 Pulse) | 13545 | 20000 | 16600 | 1200 | 25~27 | 150~200 | 3400 | 0.1~0.15 | 0.25~0.3 | 40 | 600-550 |
29 | GW-50-22000/0.2J | 22000 | 950 (24 Pulse) | 14932 | 22000 | 18300 | 1200 | 25~28 | 150~200 | 3400 | 0.1~0.15 | 0.25~0.3 | 50 | 600-550 |
Note:
(1) GW - means medium frequency induction furnace, - 1 - means induction furnace capacity of 1 ton, - 500 - means furnace rated power of 500 KW, / 1 - means furnace operating frequency of 1000 Hz, / 0.5 - means melting furnace frequency of 500 Hz, - J - means hydraulic tilting furnace (furnace shell is steel shell), - JJ - means mechanical tilting furnace. (the shell of the furnace is aluminum alloy).
(2) The above quoted price is for routine configuration. Other configurations can be added, such as leak alarm, water temperature alarm, furnace switch, cover mechanism, lining ejector and transformer, cooling device (open and close cooling tower, closed cooling tower, plate heat exchanger)
3) If necessary, send technicians to carry out the commissioning: the domestic section is free; the overseas section travel expenses, accommodation and food are borne by the user and each person is subsidized 150 US dollars per day.
4) I quote EX-W at a price including simple packing, including shipping charges to Shanghai port area and all inland charges in China.
V) The above electric furnace voltage levels are 380V, 690V and 950/1000V, and the frequency is 50HZ. If the user equipment requirements are different from the above voltage levels and frequencies, each item needs to be increased by 15000USD.