Partial Discharge Test System PD Free Tester for CT PT

Min.Order: 1
Product origin: Wuhan, Hubei, China
Infringement complaint: complaintComplaint
US$ 5000 ~ 10000

Description



General introduction

It is mainly used for testing frequency voltage insulation level of various insulation materials, insulation structure and electrical products, also as partial discharge frequency testing power supply for testing object such as transformer, mutual inductor and lightning arresters. It widely used in electrical manufacturing, power operation departments, research institutes and universities.

GDYT System 10kVA/100kV composition


1. Hipot Test Control Table GDYD-10/100       
2. PD-free Gas type transformer YDQW-10/100  
3. Coupling capacitor  TAWF-600pF/100kV       
4. Protective resistor GR100kV            
5. Isolation filter LBQ-10kVA                   
6. Partial discharge detector 
7. Other accessories       
 

 
Hipot control Unit (GDYD table) and PD-free testing transformer are controlling and voltage boosting for test object which boosted to the rated voltage.
 
Partial discharge detector(GDJF-2008) is detecting and displaying partial discharge capacity.
 
Isolation filter(LBQ) is device of anti-interference caused by power supply.
 
Coupling Capacitor is transmitting partial discharge signal to partial discharge detector.


Features

320*240 LCD screen,high speed thermal printer.
HV voltage,HV current,LV voltage,LV current measuring mode,High-precision sensor and high performance 14digit AD acquisition chip.
Real-time show HV voltage,HV current,LV voltage,LV current,time and withstand result.
Zero-returning detection.When it it back to zero,the test can be started.
Insulation resistance detection function,show insulation strength of test object directly.
Advanced PD-free epoxy insulating sleeve, small partial discharge capacity.
Low impedance voltage.
Automatic control technology, good anti-interference performance.
Rapid electronic protection, high reliability.


System Specifications
 
Power supply220V±22V,50HZ
Rated Capacity10kVA
Output Voltage100kV
Output current100mA  
Input Voltage200V, current: 50A
short-circuit impedance≤ 8%
Operation time60mins@100% rated voltage and current.
Continuous working@ 50% rated voltage and current.
Wave form distortion rate<5% when voltage regulator input voltage distortion rate <3%, within 10-100% rated voltage range
PD value≤8pC @ 100% rated voltage
≤5pC @ 80% rated voltage






Product Tag:
Related categories:
Scroll to Top