India 3 Phase Error Electric Meter Testing Instruments for Site

Min.Order: 1
Product origin: Beijing, China
Infringement complaint: complaintComplaint
US$ 88 ~ 100

Description
Product description




The GF302D India manufacturers 3 phase error electric meter testing instruments for site is used for grid corporation of measurement and energy test center, management department of power supply bureau, national energy measurement of testing authorities, and also used to test each kind of single/three phase kWh meter of industries and mining enterprises as well as electric meter manufacturers. Meanwhile, the calibrator also can be used as one high precision standard power source.
Features
1. Able to test basic error, shunt running, start, standard error automatically and manually in single-step of single/three
phase, according to relative regulation of kWh meter.
2. Able to do change test caused by voltage influence, frequency influence and harmonic influence.
3. Output of power source is speedy and stable, AC maximum output of each phase can reach 120A in maximum.
4. Voltage, current and phase position of each phase can be adjusted in split-phase, improving the flexibility of
power source.
5. Frequency of each impulse input port can reach 40Hz.
6. 7-inch TFT color display touch screen, English menu, simple and convenient operation, commonly used functions
and current basic load point can be controlled in one button.
ti-7. Each meter position can provide one standard, dependent RS485 port, and able to do mul-function test such as communication test.
8. Impulse port of each meter position, external polarity can be set randomly, able to adapt kWh meter of impulse cascade and common-anode.
Parameters
Electrical parameters 
Accuracy0.05%, 0.1%
Power SupplyOne Phase AC 180-265V, frequency 50/60Hz.
AC Voltage Output
Range(U1,U2,U3)57.7V, 100V, 220V, 380V
or 69.3V, 120V, 240V, 480V( optional)
Adjustment range(0-120)%RG(1)
Adjustment fineness0.01%RG, 0.1%RG, 1%RG, 10%RG as optional.
Stability0.01%/120s
Distortion0.3% (Non-capacitive load)
Output loadeach phase 25VA
Measuring accuracy0.05%RG
AC Current Output
Range(I1,I2,I3)200mA, 1A, 5A, 20A, 100A
Adjustment range(0-120)%RG
Adjustment fineness0.01%RG, 0.1%RG, 1%RG, 10%RG as optional.
Stability<0.01%/120s
Distortion≤0.3% (Non-capacitive load)
Output load45VA
Accuracy0.05%RG
Power Output 
Active power output stability<0.01%RG/120s
Reactive power output stability<0.02%RG/120s
Active power measuring accuracy 0.05%RG
Reactive power measuring accuracy0.1%RG
Phase Output 
Output adjustment range0°-359.999°
Output adjustment fineness10, 1, 0.1, 0.01 as optional.
Resolution0.01°
Accuracy0.05°
Power Factor
Adjustment range-1 ~ 0 ~ 1
Resolution0.0001
Measurement accuracy0. 0005
Frequency Output 
Adjustment range45Hz-65Hz
Output adjustment fineness5Hz, 1Hz, 0.1Hz, 0.01Hz as optional.
Resolution0.001Hz
Accuracy0.005Hz
Voltage /Current/Harmonic Setting
Harmonic number2-51times
Harmonic content0-40%
Harmonic phase0-359.99
Harmonic setting accuracy(10%±0.1%)RD(2)
Power Energy Measurement Error
Active power energy0.05%RG
Reactive power energy0.1%RG
Power Pulse Output 
Power pulse typeactive pulse, reactive pulse
Active power pulse output 5V,  10mA
Power Pulse Input
Energy pulse typesupport active and reactive pulse, the highest frequency power pulse input is 180K.
Mechanical parameters
Dimensions (W×D×H) (mm)500x600x175
Weight (kg)About 27
(1) RG means range, the same as below;
(2) RD means the setted harmonic content, harmonic can be a single output, also multiple output.
Product Tag:
Related categories:
Scroll to Top