Yj-F3 ICU Monitor Vital Signs Monitor (7 inches)

Min.Order: 1
Product origin: Zhengzhou, Henan, China
Infringement complaint: complaintComplaint
US$ 400 ~ 450

Description
YJ-F3 Vital Signs Monitor (7 inches)
 




The F3 vital signs monitor is engineered for the mobile, precise and fast recording of vital signs data at clinics, hospitals and outpatient treatments.

Ergonomical design and highly developed technology resulting in reliable measurement results and time efficiency.

12V DC power supply for ambulance use

An optional HDMI output eases observation from a long distance.


Features
 
Core
Newly advanced A8 main board with Linux OS, calculating speed is 4 times faster than traditional products

Support storage of 2160 hours trend table and graph review, 2 hours waveform review, 2000 groups NIBP review and 2000 alarm events review
Body
7 inch high-brightness TFT LED

Standard touch screen configuration

Optional HDMI output
Printer
USB External high-speed 50mm thermal printer (Brand: SEIKO, Japan)
 
Central System
Optional Build-in wireless network module, supporting wired or wireless connection to the central monitoring station.

Optional Support HL7 (Health Level Seven)
Linux OS
Multi-display mode to meet different clinical requirement

NIBP self-test mode: including overpressure test, static pressure test and air leakage test.

Generate ID automatically when register a new patient

Support medical history search by patient ID, name and mobile number

Optional infrared thermometry allows clinicians to obtain patient's temperature using non-invasive infrared technology that detects heat from the skin's surface

18 types of Arrhythmia analysis and real-time S-T segment analysis and pacemaker detection

Drug calculation and titration table

Support multi-language display

Support online software upgrading by net/USB

Suitable for monitoring adult, pediatric and neonatal patient.


Related Product

 Performance Specifications
 
Dimension and Weight
- Dimension: 210mm*130mm*75mm
- Weight: 1kg(excluding accessories)

Power Supply
- Voltage: AC100~240V, 50/60HZ
- Adapter: Output 9VDC, 5A

Display
- 7" color TFT LED
- Resolution: 800*480 pixels

Battery
- Type: Rechargeable lithium battery 7.4V/2200mAh
- Charge Cycle: ≥500 times
- Working time: 2-3 hours (optional larger battery for 4-5 hours)

Recorder (Option)
- Method: USB External Thermal printer
- Paper width: 50 mm (1.97 in)
- Printing speed: 12.5/ 25/ 50 mm/s
- Trace: Max. 3 tracks
- Recording way: Real-time Recording, Review Printing, Periodic Recording, Alarm Recording

Alarm
- Level: Low, medium and high
- Indication: Auditory and visual
- Alarm volume adjustable
- Alarm pause time: 1min, 2min
- Parameter alarm type: Latch/ Unlatch

ECG
- Lead mode: 3/5 Leads, I, II, III or I, II, III, AVR, AVL, AVF, V
- Protection: Breakdown Voltage 4000VAC 50/60Hz; Defibrillator proof
- Gain: 2.5mm/mV (×0.25), 5.0mm/mV (×0.5), 10mm/mV (×1), 20mm/mV (×2), 40 mm/ mV (×4), Auto
- Sweep speed: 6.25mm/s, 12.5mm/s, 25mm/s, 50mm/s
- ECG signal range: ±12 mV (Gain × 0.25)
- Accuracy: ±1bpm/ ±1%, whichever is greater
- Resolution: 1 bpm
- Leakage Current < 10 μA
- Baseline Recovery:
≤ 3s after defibrillation (Monitor mode)
≤ 1s after defibrillation (Surgery mode)
- Bandwidth:
Surgery 1 ~ 25 Hz
Monitor 0.5 ~ 40 Hz
Diagnostic 0.05 ~ 120 Hz
- Indication of Electrode Separation: Every electrode (exclusive of RL)

Respiration
- Method: Impedance between RA-LL, RA-LA
- Gain: ×0.25, ×0.50, ×1, ×2, ×4
- Respiration Rate: 0bpm, 6 ~ 150 BrPM
- Sweep speed: 6.25 mm/s, 12.5 mm/s, 25mm/s
- Resolution: 1 BrPM
- Accuracy: ±2 bpm or ±2%, whichever is greater
- Apnea Alarm: 10 ~ 60 s

Temperature
- Technique: Thermistor probe (2.25K)
- Channel: Single-channel
- Measuring and Alarm
Range: 0.0 ºC~ 50 ºC (32ºF~ 122ºF)
- Unit: Celsius (ºC), Fahrenheit ( ºF)
- Resolution: 0.1ºCor 1ºF
- Accuracy: ±0.1ºC(exclusive probe)
Input Device
- Touch screen (standard)
- Touch pen (standard)

System Output & Extensible

Interface

- Ethernet Network: 1 standard RJ45 socket
- USB Port: 1
- Video Output: 1 HDMI port (option)

Operating Environment
- Temperature: 5 ~ 40 ºC
- Humidity: 15% ~ 80% (non-condensing)
- Atmosphere pressure: 86 KPa ~ 110 KPa

Transportation and Storage

Environment

- Temperature: -20~50 ºC
- Humidity: 10%~90% (non-condensing)
- Atmosphere pressure: 86 KPa ~ 110 KPa

Safety
- IEC60601-1 Approved, CE marking according to MDD93/42/EEC
- With reference to RoHS Directive 2011/65/EU recasting

Trend & Reviewing
- Trend: 2160 hours
- ARR events: 128 groups of ARR events and associated waveform
- NIBP measurement reviewing: 2000 groups
- Waveform review: 2 hours
- Alarm event: 2000 groups of parameter alarms events and associated parameter

Heart Rate
- Measure range:
Adult: 0bpm; 10 ~ 300 bpm
Neo/Ped: 0bpm; 10 ~ 350 bpm
- Resolution: 1 bpm
- Accuracy: ± 1% or ± 1bpm, whichever is greater

ST Measurement
- Range: -2.0 ~ +2.0 mV
- Accuracy: -0.8mV~ +0.8mV: ±0.02mV or ±10%, whichever is greater
- Other range: unspecified
- Resolution: 0.01mV

NIBP
- Method: Oscillometric
- Measure mode: Manual, Auto, STAT
- Measure Interval in AUTO Mode 1~480 min
- STAT mode cycle time: Keep 5 minutes, at 5 seconds interval
- Measure and Alarm Range:
Adult: SYS: 30 ~ 270 mmHg
DIA: 10 ~ 220 mmHg
MEAN: 20 ~ 235 mmHg
Pediatric: SYS: 40 ~ 235 mmHg
DIA: 10 ~ 220 mmHg
MEAN: 20 ~ 225 mmHg
Neonate: SYS: 30 ~ 135 mmHg
DIA: 10 ~ 110 mmHg
MEAN: 20 ~ 125 mmHg
- Static pressure accuracy: ±3mmHg
- Resolution: 1mmHg
- Accuracy:
Maximum Mean error ±5mmHg
Maximum Standard deviation ≤8mmHg
- Over pressure Protection: Dual protection via software & hardware


Pack and Delivery