Description
Servers, Data centers, Critical network devices, Sensitive electronic equipment, Telecom.
  • Online-Double conversion
  • Non Transfer Time of output
  • PFC technology
  • Full digital control (DSP)
  • Output power factor: 0.8
  • Input current harmonic: 5%
  • ECO function
  • Charging/Rectifier/Inverter fully digital control technology
  • Optimization battery group, the quantity of battery: 16/18/20 pieces (optional)
  • Wide input voltage range: 304~478VAC
  • Wide input frequency range: 40~70Hz±0.5Hz
  • Self-testing when UPS startup
  • Input over/under-voltage protection
  • Automatic bypass
  • DC start
  • Fault isolation
  • Comunication port: RS232 , dry contact,RS485*2
  • Options: SNMP card/Centralized monitoring card/ Parallel port module

body {background: #C0EBC6 !important;}div {background-color: #C0EBC6 !important;}header,nav,table,th,tr,td,dl,ul,li,ol,fieldset,form,h1,h2,h3,h4,h5,h6,pre {background: transparent !important;}* {color: #363636 !important;}a:link,a:link *,a:link:hover,a:link:hover *,a:link:active,a:link:active * {color: #3E3822 !important;}a:visited,a:visited *,a:visited:hover,a:visited:hover *,a:visited:active,a:visited:active * {color: #0060BF !important;}
MODEL STANDARD C6K C10K C6KS C10KS 3C10KS 3C15KS 3C20KS
CAPACITY VA/W 6KVA 4.8KW 10KVA 8KW 6KVA 4.8KW 10KVA 8KW 10KVA 8KW 15KVA 12KW 20KVA 16KW
INPUT Nominal Voltage 220/230/240VAC 380VAC
Voltage Range 120-275VAC 210-475VAC
Frequency  Range 46-64Hz: 50Hz, 60Hz auto sense
Phase Single phase with Ground Three phase  (4 Wires+Ground)
Power Factor >=0.99 >=0.95
OUTPUT Voltage 220/230/240*(1±1%)VAC
Frequency 50/60Hz(Adjustable)
50Hz AC Mode: Follow AC Mode (AC Range 46~54Hz); Battery Mode: 50Hz(1±0.1%)
60Hz AC Mode: Follow AC Mode (AC Range56~64Hz); Battery Mode: 60Hz(1±0.1%)
Wave Form Pure Sine Wave
Power Factor 0.8
Harmonic  Distortion =<2% THD (Linear Load), =<6% THD (Non-Linear Load)
Overload  Capacity Normal when load < 105%; 105%-125% for 1 min, 125%-150% for 30sec
Current  Crest Ratio 3:1
Connections Terminal block
Efficiency To AC Mode 88% 85%
To Battery Mode up to 90%
Battery Type Sealed free maintenance lead acid battery
Nominal  DC voltage Built in batteries 12v7.2ah*16pcs 192VDC 192VDC
Quantity 16pcs 16pcs Depends on  requested  back-up time Depends on requested  back-up time
Back-up Time  (Full load) >=7 minutes >=5 minutes Depends on the  capacity of  external battery bank Depends on the  capacity of  external battery bank
Recharge Time 7 hours to 90% Depends on the  capacity of  external battery bank Depends on the  capacity of  external battery bank
Charge current (MAX) 2.0A 4.2A or 8A 4.2A or 8A
Charge voltage 220Vdc ± 1%
Bypass Automatic  Transfer On overload and UPS failure
Before UPS  Power-on Default "ON" user adjustable to "YES"
Transfer Time   Zero
Indicators LED Display UPS status, I/P & O/P voltage& frequency, Battery voltage, Battery capacity, Loading, Fault code
Audible Alarm   Bypass, On battery mode, Battery low, Overload, Fault
Acoustic noise At 1 meter  distance <55dB <60dB
Communications Intelligent  RS232 serial  port Windows 98/NT/2000/XP/2003, Linux, Sun Solaris, IBM Aix,  Compaq True64, SGI IRIX, FreeBSD, HP-UX, and MAC
SNMP  (Optional) Power management from SNMP manager and web browser
USB  (Optional) Windows family software and Mac OS
Environmental Operating  Temperature 0~40 °C
Operating  Humidity 20~90% ( Non Condensing)
Weight Net weight  (kg) 57 67.5 18 20 27 35 35
UPS Dimension L*W*H  (mm) 500*248 *616 500*248 *616 500*240 *460 500*240 *460 500*248 *616 500*248 *616 500*248 *616