Flame Type Atomic Absorption Spectrophotometer with Cu Hollow Cathode Lamp

Min.Order: 1
Product origin: Suzhou, Jiangsu, China
Infringement complaint: complaintComplaint
US$ 6000 ~ 15000

Description
Product Description

Instrument introduction

AAS6000 Series are Double Beam Atomic Absorption Spectrometers controlled and data processed by external computer and internal CPU chips. AAS6000 can be used to measure the concentration of macro, micro and trace metal elements and half-metal elements in various kinds of substances. 

Atomic absorption spectrometry is a technique exploiting the fact that atoms at ground state may absorb the radiation of characteristic wavelength. As is known, the atoms are usually at ground state. For each element, the amount of energy required for an atom to transit from ground state to excited state is specific, and in general, is called characteristic wavelength. The Atomic absorption spectrometry typically makes use of hollow cathode lamp as the light source to emit the characteristic wavelength of a particular element. When the light passes through the atomic vapor, it is absorbed by the vapor. The concentration of the element can then be determined through the calculation of the absorption rate. 
AAS6000 is provided with three reading methods Continuum, Retention and Peak Height for measuring absorbency, density and emission intensity. It has three signal modes: Atomic Absorption, Background Absorption and Background Correction Absorption, The reading time ranges from 0.5 s to 99s. AAS6000 include 8 computer controllable hollow cathode lamp holders. All working conditions of the instrument such as lamp number, lamp current, negative high voltage, working wavelength, slit, burner location, ignition/extinction and adjustment of burning ratio can be set by keyboard input. The functions of the instrument include automatic gain/ automatic zero, background correction, automatic energy balance, automatic peak location/wavelength scan, and automatic peak location on basis of the retrieval of peak values. All the readings, measurement results, calibration curves and operation conditions can be saved or printed out.

Product Parameters

Performance characteristics

C2H2 monitoring; flame measurement; all reflective, aberration corrected
Fully automated instrument, total automatic operation 
8 element lamps, time saved for changing lamps
Gas path safety measures, safer operation
USB interface allows you to operate the instrument conveniently and rapidly.
230nm grating blazed wavelength, multiplied sensitivity in the Ultraviolet zone
1800g /mm grating grooves, maximized resolution
Run in Windows operating system, the powerful software enables automatic qualitative and quantitative analysis. Automatic report generation in Excel format allows you to operate the instrument and process the data easily. You operation doest get any easier with our graphical interfaces.

Technical specifications

Model: AAS6000
Optical system: all-reflective single-beam CT optical path
Focal length of monochromator: 350mm, oil/water proof air compressor
Blazed wavelength of gratings: 230nm
Number of grating grooves: 1800g /mm
Wavelength range:  190nm-900nm
Wavelength accuracy:  ±0.1nm 
Wavelength repeatability: ±0.1nm
Spectrum bandwidth: 0.1nm, 0.2nm, 0.4nm, 0.7nm, 1.4nm 
Noise: 0.005 Abs(static); 0.006 Abs(Dynamic)
Baseline drift: 0.003 Abs/0.5h; best performance
Background correction: D2 lamp + self reversal 
Number of the lamps: 8 
Number of preload lamps: software controlled, ≤8
Gas path safety measures: yes 
Atomizer: flame atomizer
Automation: lamp / slit / wavelength / gas path / ignition / burner / safety measures / C2H2 monitoring

Standard configurations

AAS6000
AAS6000 mainframe 
Oil-free air compressor with lower noise
Special pressure gauge and peripheral accessories
Hollow cathode lamp
PC (brand computer, P4, LCD) 1 set
Printer (Canon, colorful ink-jet printer) 1 set
Wooden case packing and transportation

Application fields

Geology, minerals, metallurgy, steel, non-ferrous metals
Environmental analyses: air, water quality, soil and solid wastes 
Petrochemical engineering, crude oil and related products, light industrial products, 
Food, biomedicine and health products 
Building materials (glass, ceramic, paints, etc) 
Steel and non-ferrous metals analysis 
Soil and solid wastes analysis 
Biomedicine and health products analysis 
Food analysi

Technical Specifications
Optical system:No lens, concave lens, total reflection, achromatic optical system
Monochromator:Czerny-Turner
Grating:1800 lines/mm
Slit:auto-switch 0.1,0.2,0.4,0.7, 1.4nm
Detector:Photomultiplier
Light source:> 8-element lamp turret
Size/weight:87cm x 56cm x 60cm, weight: 100kg
Flame System Specifications
Safety protection:System leakage/ System pressure/ Burner monitoring with automatic shut-off
Combustion system:Atomizer, Pure Ti Atomizing Chamber & Burner
Flame Atomiser positioningSoftware controlled horizontal and vertical positioning
Discharge System:Manual
Product Tag:
Related categories:
Scroll to Top