1.Has protection function
Item | Value |
Operating speed | 0.1mm-1m/s (no lever) |
Operating frequency | Mechanical 60 cycles/min; electrical 25 cycles/min |
Insulation resistance | ≥100MΩ(500VDC) |
Contact resistance | ≤50mΩ |
(Test voltage) Between non-continuous terminals | AC1000V , 50/60Hz , 1min |
(Test voltage) Between each terminal and other exposed metal parts Between each terminal and ground | AC1500V , 50/60Hz , 1min |
Vibration resistance | 10-55Hz , 1.5mm Double amplitude |
Shock resistance | endurance : 1000m/s2 Wrong action : 300m/s2 max |
Electric shock proof protection grade | II class |
Degree protection provided by enclosure | IEC IP60(specific specification) |
Life | Mechanical≥1,000,000 cycles Electrical ≥ 50,000 cycles |
Safety approvals | UL ,CUL, TUV,CE, SEMKO |