Multi Jet Dry type
Material body: Brass
Sizes: DN15 to 50mm, (½" - 2"), Available for cold water (40°C), hot water (90°C)
Accuracy: DN15(½"), Class B / Class C / R160
DN20-50mm, (¾" - 2") Class B
Universal use. Easy for interchange & maintenance
1 liter/pulse, 10 liters/pulse, 0.1 gallon/pulse, 1 gallon/pulse
MAIN TECHNICAL DATA According to ISO4064 (GB/T778.1-1996) Standard
Size | Class | Qs Overload flow | Qp Nominal flow | Qt Transitional flow | Qmin Min flow | Min reading | Max reading | |
DN(mm) | Inch | m³/h | L/h | m³ | ||||
15 | 1/2" | A | 3 | 1.5 | 150 | 60 | 0.0001 | 99999 |
B | 120 | 30 | ||||||
C | 22.5 | 15 | ||||||
20 | 3/4" | A | 5 | 2.5 | 250 | 100 | 0.0001 | 99999 |
B | 200 | 50 | ||||||
C | 37.5 | 25 | ||||||
25 | 1" | A | 7 | 3.5 | 350 | 140 | 0.0001 | 99999 |
B | 280 | 70 | ||||||
32 | 11/4" | A | 12 | 6 | 600 | 240 | 0.0001 | 99999 |
B | 480 | 120 | ||||||
40 | 11/2" | A | 20 | 10 | 1000 | 400 | 0.001 | 99999 |
B | 800 | 200 | ||||||
50 | 2" | A | 30 | 15 | 1500 | 600 | 0.001 | 99999 |
B | 1200 | 300 |
MAIN TECHNICAL DATA According to ISO4064 (GB/T778.1-2007) Standard
DN SIZE | Mm Inch | 15 1/2" | 20 3/4" | 25 1" | 32 11/4" | 40 11/2" | 50 2" |
Q4(m³/h) | 3.125 | 5 | 7.875 | 12.5 | 20 | 31.25 | |
Q3(m³/h) | 2.5 | 4 | 6.3 | 10 | 16 | 25 | |
R80 | Q2(L/h) | 50 | 80 | 126 | 200 | 320 | 500 |
Q1(L/h) | 31.25 | 50 | 78.75 | 125 | 200 | 312.5 | |
R100 | Q2(L/h) | 40 | 64 | 100.8 | 160 | 256 | 400 |
Q1(L/h) | 25 | 40 | 63 | 100 | 160 | 250 | |
R125 | Q2(L/h) | 32 | 51.2 | 80.64 | 128 | 204.8 | 320 |
Q1(L/h) | 20 | 32 | 50.4 | 80 | 128 | 200 | |
R160 | Q2(L/h) | 25 | 40 | 63 | 100 | 160 | 250 |
Q1(L/h) | 15.62 | 25 | 39.37 | 62.5 | 100 | 156.2 | |
Min reading(m³) | 0.00005 | 0.00005 | 0.00005 | 0.00005 | 0.001 | 0.001 | |
Max reading(m³) | 99,999 | 99,999 | 99,999 | 99,999 | 99,999 | 99,999 | |
Max pressure(MAP) | 16 | 16 | 16 | 16 | 16 | 16 | |
Max loss(ΔP) | 63 | 63 | 63 | 63 | 63 | 63 | |
Max temperature | T50 | T50 | T50 | T50 | T50 | T50 | |
Pulse output option | Vmax=24V, Imax=100mA, Pmax=2W |
INDICATING ERROR
At low zone is ±5% from minimum flow rate (qmin) to transitional flow rate (qt) exclusive boundary
At high zone is ±2% from transitional flow rate (qt) to overload flow rate (qs)
WORKING CONDITION
Water temperature:≤40ºC for cold water meter
Water temperature:≤90ºC for hot water meter
Working pressure:≤1.6Mpa