BOOTH DIMENSIONS | |
Internal dimensions | 6900×4000×2800mm (L×W×H) |
External dimensions | 10670×4110×3610mm(L×W×H) |
BASEMENT | |
Base design | Galvanized sheet bending forming, Full grids, 350mm high |
Carrying capacity of the grids | 650kg/Wheel |
Filter area | 27.6SQM |
Drive-in-ramps | 2 ramps,size:2000*520mm |
Grids description | size: 997*756mm, 40*3mm, The grids are made of pressed steel lattices. |
CABIN | |
Cabin structure | Wall panel vertical insert |
Top Plenum | 400mm |
Rear wall panel | 50mm dual-skin insulated panels filled with heat resistant |
Ceiling panel | Galvanized roof bending forming |
PVC curtain | (colors optional: grey, blue, red, yellow) |
Form of curtain | PVC |
Arrangement and quantity | Front 1 set , side 2 .color : middle transparent , both ends white. |
Ceiling lights | (LED lighting system) |
Quantity and power | 8 sets of light fixtures, each 4 X 18W, 576W total |
arrangement mode | on both side |
Lighting description | IP55 Protection grade IP55 |
Illumination | >700Lux |
Filter system | |
Pre-Filter | G2 grade Fiberglass paint arrestor filter |
Ceiling filter | F5 class filter cotton, Model 600G |
Floor filtration | G2 grade Fiberglass paint arrestor filter |
EXHAUST UNIT | |
Exhaust fan type | Direct-type turbine fan |
Power and motor description | 1×5.5KW, 970RPM, 380V, 50HZ; |
Parameters of exhaust | 18000m³/h ;650pa |
Ductwork | |
Straight ducting | 3 piece |
90° elbow | 1 piece |
CONTROL SYSTEM | |
Operative standard | Standard Y / Δ Step-down starting Control system |
Function | Fan start, electric throttle adjustment, emergency stop switch, fault indication |
SPECIAL DESCRIPTION PROJECT | RATED POWER:8.5KW |