Sinnor Multi-Parameter Patient Monitor with WiFi Centre System (SNP9000M)

Min.Order: 5
Product origin: Shenzhen, Guangdong, China
Infringement complaint: complaintComplaint
US$ 300 ~ 1500

Description
Sinnor Multi-Parameter Patient Monitor with WiFi Centre System (SNP9000M)

 





 






Function:

Display: 15" color TFT screen, high resolution: 1024×768 dpi;
6 Parameters: Standard - 5-lead ECG/HR, NIBP, SPO2, Temp., Resp., PR;                  Optional - 3/12-lead ECG, single/double IBP, double Temp., Sun Tech NIBP, Masimo/Nellcor Spo2, ETCO2,BIS,CO;
Patient Range: Suitable for Adult, Pediatric, Neonate;
Multi-display interface: Standard, Large font, Trend Coexist, OxyCRG dynamic, full ECG waveforms;
Language: Built-in 8 language for choose (English, Chinese, Turkish, Spanish, French, Russian, German, Italian);
Review: Maximum 720h tabular and graphic trends of all parameters, 1000NIBP records and 200 alarm event;
Battery: Built-in 2 hours rechargeable lithium battery, and battery volume  display. 4 hours rechargeable lithium battery (optional);
Network: TCP/IP networking platform, connect with central monitoring system. Wifi central monitoring system (optional).


Feature:

Advance patient Manage: gender, full name, ID no., room no., bed no.,  weight,height, blood type, paced or not, remakes;
Multi-parameter board: Separated parameter board, main board, ECG board, SPO2 board, and NIBP board are independent;
Interface: Color, layout of each parameters can be set up by user need, bed to bed view display(optional);
Fanless: Use special fanless cooling technology in the device to provide users quiet environment;
Standby: Unique standby mode for energy saving and suspend monitoring;
Time delay: Time delay switch-off function to save data when monitor turn off suddenly;
Easy software update: Users can update monitor software by themselves;
Analysis: Real time S-T segment analysis, and 20 type arrhythmic analysis; SpO2 Pitch Tone Variation, Drug Dose Calculation and Hemodynamic Calculations;
Storage: external SD card slot enables memory extension(optional);
Data transfer: USB port to allow to transfer patient data to a PC (optional);
Special SINNOR F-6 Spo2 technology: which is as correct as Nellcor spo2 but cheaper than it(optional);
Resistance to interference : Efficient resistance to interference of defibrillator and HF knife;
Other optional: Touch Screen, Printer, Wall amount, VGA connect



Optional: Touch Screen, Printer, 3/12-lead ECG, 2/4-IBP,4-TEMP,2-SpO2, Nellcor/Masimo SpO2,BIS, Phaisein/ Respironics Multi-gas, ICG/CO, ETCO2, Sun Tech NIBP, Wall mount, VGA, Wifi


Performance Specifications



Display
15"color TFT
Rolling and refreshing waveform display
Resolution: 1024×768
Multi display selectable including:
Standard display
Large-font display
Trend coexist display
OxyCRG dynamic view display
7 full ECG waveforms display
Bed-to-bed view display(optional)
Trace
9 waveforms (7 ECG, 1 SPO2 and 1 RESP)
Sweep speed:6.25mm/s, 12.5mm/s,25mm/s,50mm/s
Indicator
Power/battery indicator light
QRS beep and alarm sound
Battery
Rechargeable lithium battery, 12v/4AH
Max.24 hour for charging, 2 hours for continue working
Trend
Parameter graphic and tabular trends:
5s/piece, 8 hours;
1min/piece,168 hours(24hour×7days)
5min/piece, 1000 hours.
Storage
NIBP: 1000 groups
Alarm: 200 groups
SD card external storage (optional)
Alarm
User-adjustable High, Medium and Low limits 3-level
Audible and visual alarm
Networking
Connected to central monitoring system
TCP/IP netting platform
Wifi connector (optional)
Recorder
Build-in, thermal array
Plethysmogram caveform:2 /3 channels
Record mode: manual, on alarm, time-defined
Recording width: 50mm
Printing speed: 50mm/s
Recording type
Frozen waveform record
NIBP recall record
Trend table record
Alarm record
Fixed -time record

Standard parameter


ECG
Lead mode:                                5 -lead(R, L, F, N, C) (3/12 lead ECG for optional)
Lead selection:                          I, II, III, avR, avL, avF, V
Waveform:                          3 and 7 channel selectable
Gain selection:                        0.5mm/mv,1mm/mv,2mm/mv
Sweep speed:                          6.25mm/s;12.5mm/s;25mm/s;50mm/s
Heart rate range:                        Adult: 15~300bpm;
Neonate/pediatric: 15~350bpm
Accuracy:                                  +1bpm or +1%, which is greater
Resolution:                          1bpm
Filter:                                            surgery mode: 1~20Hz
Monitor model: 0.5~40Hz
Diagnostic mode: 0.05~130Hz
Scaling signal:                          1mv, +3%
Protection:                        withstand 4000VAC/50 voltage isolation against electrosurgical interference and defibrillation
Alarm range:                            15~350bpm
S-T segment detection:                 
Measurement range:    2.0mV~+2.0mV                       
Alarm Range:          -2.0mV~ +2.0mV
Accuracy:              -0.8mV ~+0.8Mv
Error:                +0.02Mv

Arrhythmia analysis:        YES
SPO2
Measurement range:        0~100%
Wave speed:              12.5mm/s;25mm/s
Resolution:                1%
Accuracy:                +2% (70-100%); 0-69% unspecified
Alarm range              0~100%
Lower perfusion situation

Pulse Rate(PR)
Range:                20~300bpm
Resolution:            1bpm
Error:                +1bpm or +2%, whichever is greater

NIBP
Method:                  Digital Automatic oscillometric
Operation mode :            Manual/Automatic
Auto measurement time:      Adjustable (1~720min)
                         (1,2,3,4,5,10,15,30,60,90,120,240,480,720min)
Measurement Unit:          mmHg/Kpa selectable
Measurement types:        Systolic, Diastolic, Mean 
Measurement Range:
Range of Systolic pressure:    Adult: 40~270mmHg
Pediatric: 40~220mmHg
Neonate: 40~135mmHg
Range of mean pressure:      Adult: 20~235mmHg
Pediatric: 20~165mmHg
Neonate: 20~110mmHg
Range of diastolic pressure:    Adult: 10~215mmHg
Pediatric: 10~150mmHg
Neonate: 10~100mmHg
Over-pressure protection:    Double safety protection
Resolution:                1 mmHg
Alarm:                    Systolic, Diastolic, and Mean

RESPIRATION
Method:                    RA-LL impedance
Measurement range:          Adult: 7~120rpm;
Neonate/Pediatric: 7~150rpm
Apnea alarm:                YES, 10~40s
Resolution:                  1rpm
Accuracy:                    +2rpm

TEMPERATURE
Compatible probe:            YSI or CYF
Measurement range:          5~50ºC
Resolution:                  0.1ºC
Accuracy:                    +0.1ºC
Refreshing time:              about 1
Average measuring time:        <10s



Others

Safety:             
Safety level: Class I, type CF

Dimension and Weight
Dimension:      28*42*48cm       
G.W:        <6.5KS

Operation Environment
Temperature:    Working 0~+40ºC
Transportation and storage -20~+60ºC
Humidity:      working≤85%
Transportation and storage≤93%
Power:          AC 100-240, 50/60Hz



Standard accessories supplies

1. 5 lead ECG cable----------------------------------------  1set
2. Adult Spo2 probe---------------------------------------  1set
3. Adult NIBP Cuff and extension tube--------------  1set
4. Temp probe----------------------------------------------  1set
5. Ground connecting liner-----------------------------  1set
6. ECG Chest electrode (10pcs/pack)----------------  1pack
7.2200mA lithium battery-------------------------------  1PCS
Product Tag:
Related categories:
Scroll to Top