High Level 380V 3phase 60Hz Variable Speed Drive for Lift

Min.Order: 1
Product origin: Quanzhou, Fujian, China
Infringement complaint: complaintComplaint
US$ 100

Description
   High Level 380V 3Phase 60Hz Variable Speed Drive For Lift

S3800E Series Closed-loop vector control - High performance:  Control of asynchronous motor and synchronous motor are implemented through the high-performance current vector control technology.
 
Overload capacity 60s for 150% of the rated current, 3s for 180%( 120%) of the rated current.
 
Ramp mode: Straight-line ramp; S-curve ramp; Four groups of acceleration/deceleration time with the range of 0.0-6500.0s
 

Item
          S3800E
Based functionsControl modeV/F(Voltage/Frequency) control
Sensorless flux vector control (VC)
Closed-loop vector control (CVC)
Maximum frequencyVector control: 0-320 Hz
V/F control: 0-3200Hz
Carrier frequency1.0-16.0 kHz
The carrier frequency is automatically adjusted based on the load features.
Input frequency esolutionDgital setting: 0.01 Hz
Analog setting: 0.025% of maximum frequency
Startup torqueG type: 0.5 Hz/150% (VC); 0 Hz/180% (CVC)
P type: 0.5 Hz/100%
Speed range1:100 (VC)
1:1000 (CVC)
Speed stability accuracy± 0.2% (VC)
± 0.02% (CVC)
Torque control  accuracy± 5% (CVC)
Overload capacityG type: 60s for 150% of the rated current, 3s for 180% of the rated current.
P type: 60s for 120% of the rated current, 3s for 150% of the rated current.
Torque boostAuto boost
Customized boost 0.1%-30.0%
V/F  curveLine  V/F  curve
Multi-point V/F  curve
N-power V/F curve (1.2-power, 1.4-power, 1.6-power,1.8-power, square)
V/F  separationtwo types: complete separation; half separation
Ramp modeStraight-line ramp
S-curve ramp
Four groups of acceleration/deceleration time with the range of 0.0-6500.0s
DC brakingDC braking frequency: 0.00 Hz to maximum frequency
Braking time: 0.0-100.0s
Braking action current value: 0.0%-100.0%
JOG controlJOG frequency range: 0.00-50.00 Hz
JOG acceleration/deceleration time: 0.0-6500.0s
Onboard multiple preset speedsIt implements up to 16 speeds via the simple PLC function or combination of  terminal states
Onboard PIDIt realizes process-controlled closed loop control system easily.
Auto voltageIt can keep constant output voltage automatically when the mains voltage changes.
regulation (AVR)
Overvoltage/ Overcurrent stall controlThe current and voltage are limited automatically during the running process so as to avoid frequent tripping due to overvoltage/over current.
Torque limit and controlIt can limit the torque automatically and prevent frequent over current tripping during the running process.Torque control can be implemented in the CVC mode.
Individualized functionsSupport for multiple PG cardSupport for rotating transformer PG card,differential input PG card, UVW differential input PG card, resolver PG card and OC input PG card
Power dip ride throughThe load feedback energy compensates the voltage
reduction so that the AC drive can continue to run for a
short time.
Rapid current limitIt helps to avoid frequent over current faults of the AC drive.
High performanceControl of asynchronous motor and synchronous motor are
implemented through the high-performance current vector
control technology.
Timing controlTime range: 0.0-6500.0 minutes
Communication methodsMODBUS-RTU,PROFIBUS-DP,CAN
Protection modeMotor short-circuit detection at power-on, input/output
phase loss protection, over current protection, overvoltage
protection, under voltage protection, overheat protection and overload protection.
Input and outputInput terminal8 digital input terminals, one of which supports up to
100 kHz high-speed pulse input.
2 analog input terminals, one of which only supports
0-10 V voltage input and the other supports 0-10 V voltage input or 4-20 mA current input.
Frequency sourceDigital setting, analog voltage setting, analog current setting, pulse setting and serial communication port setting.
Auxiliary frequency sourceThere are ten auxiliary frequency sources.It can implement
fine tuning of auxiliary frequency and frequency synthesis.
Running command sourceOperation panel/Control terminals/Serial communication port
You can perform switchover between these sources in
various ways.
Output terminal1 high-speed pulse output terminal (open-collector) that
supports 0-100 kHz square wave signal output
1 digital output terminal
2 relay output terminal
2 analog output terminal :that supports 0-20 mA current output or 0-10 V voltage output
operation on the operation panelLED displayIt displays the parameters.
Key locking andIt can lock the keys partially or completely and define the
function selectionfunction range of some keys so as to prevent mis-function.
Optional partsRotating transformer PG card,differential input PG card, UVW differential input PG card, resolver PG card and OC input PG card
EnvironmentInstallation locationIndoor, free from direct sunlight, dust, corrosive gas,
combustible gas, oil smoke, vapour, drip or salt.
AltitudeLower than 1000 m
Ambient temperature -10°C ~40°C (de-rated if the ambient temperature is
 between 40°C and 50°C)
HumidityLess than 95%RH, without condensing
VibrationLess than 5.9 m/s2 (0.6 g)
Storage temperature -20°C~60°C
 
Wring diagram

Target market of S3800 E series inverter:  
               
Extruder                      mill ball 
Elevator and lift                Textile equipment
Paper machinery               Screw output device
Drawing Equipment             Dyeing plant
Injection plastic equipment       Air conditioning system
Machine tool equipment         Boiler system
Chemical fiber equipment      Water supply, oil transportation installation. Etc







Contact person:Maggie Huang
Moblie:86-18650771915

Product Tag:
Related categories:
Scroll to Top