Water Cooled 10kw 12000rpm High Speed Brushless AC Motor

Min.Order: 1
Product origin: Shenzhen, Guangdong, China
Infringement complaint: complaintComplaint
US$ -1

Description
Water Cooled 10KW 12000RPM High Speed Brushless AC Motor

Product Feature
1.Suitable for the 12000rpm high speed
2.Reserve a large margin of security
3.High power & high torque
4.High efficiency
5.Small size
6.Low noise low vibration
7.The autonomous patented cooling structure


Specifications
Model type: SRPM112H4W10
Voltage: 230V AC
Rated Power: 10KW
Rated Torque:8N.m
Rated Speed: 12000rpm
Maximum Speed:13500rpm
Isolation: H
Cooling Method: water cooling
Ingress Protection:IP54(IP67 option)
Pole:4


Application
1.Hydrogen Oxygen air compressors
2.Hydrogen circulating system





Other motors you will be interested in
Motor typeVoltage
(V AC)
Rated power
(kW)
Rated torque (N.m)Rated speed
(rpm)
Efficiency
(%)
Duty type Insulation  Ingress protectionPole NumberWeight
(kg)
Cooling Methodposition signal
SRPM160H4XO15380155.962400096.5S1H/FIP67412Oil Resolver
SRPM160H4XO753807535.82000096.5S1H/FIP67444Oil Resolver
SRPM160H4XO9038090432000096.5S1H/FIP67448Oil Resolver
SRPM205H4XO11038011052.52000096.5S1H/FIP67476Oil Resolver
SRPM205H4XO16038016076.42000096.5S1H/FIP67486Oil Resolver
SRPM205H4XO20038020095.52000096.5S1H/FIP67495Oil Resolver

FAQ
1. Can performanent magnet synchronous motor be used as generator? 

No. Permanent magnet synchronous motor is absolutely different from generator. It is only ac motor that outputs speed and torque to drive electric devices, but not power supply. 
 
2. Why can not directly use three phase ac supply voltage to start permanent magnet synchronous motor? 
Becuase rotor is with big innertia, and magetic files spins so fast that static rotor has no way to spin with magetic filed. 
 
3. Any special technical request on this motor's VFD driver? And Do you have such driver? 
Permanent magnet synchronous motor's driver should be vector control VFD with special inner software, such as Siemens 6SE70 series, Yakawa CR5 series, ABB ACS800 series, Mitsubishi A740 series, B&R P84 and P74 series, etc.. Yes, our MH300 series VFD matches with this motor. 
 
4. Is there any protective measures to defend permanent magnet rotor from failure? 
Yes, each permanent magnet rotor passes corrossion resistance, consistency, high temperature demagnetization test, linear demagnetization test, etc. Its demagnetization index is within 2%. But if working environment is serious oxiditive corrosion, kindly advise for higher protection level. 
 
5. Where is this permanent magnet synchronous motor normally used to? 
This permanent magnet synchronous motor is normally used to variable frequency speed situation.










Product Tag:
Related categories:
Scroll to Top