Automatic Oscillation Manual Synchronized Asynchronized Hospital Defibrillator Monitor for Sale

Min.Order: 10
Product origin: Shanghai, China
Infringement complaint: complaintComplaint
US$ 2000 ~ 3000

Description




Hot Sale Hospital medical equipment Manual AED Automated External Defibrillator With Optional ECG SPO2 monitor
 
 
JRXPress is a compact, durable, light weighted defibrillator
which integrated monitoring, manual defibrillation, AED and pacer (option).
It is a professional biphasic defibrillator-monitor suitable for hospitals and clinics,
 
JoRadiant developed JRXpress with ECG monitoring paddles and Optional SpO2 (Nel lcor, Meditech) NIBP, EtCO2 and PC Software
 
Display
• Screen Type:  High-resolution display
• Screen Size: 7 inches (17.7 cm) diagonally
• Sweep Speed: 25mm/sec
• Information: Heart Rate, Lead/Pads, Alarm On/Off, SpO2, AED
• Functions and Prompts Alarm Selection and Limits, Delivered Energy. 
 
Defibrillator
• Waveform: Biphasic
• Charge Time: Less than 7 seconds with a new fully charged battery.
• Energy Display: Monitor display indicates both selected and delivered energy.
• Charge Prompt Type: Voice and visual prompts.
• Electrode Impedance Measurement Range: 0250 ohms. 
 
ECG Monitoring
• Patient Connection: 3-lead ECG cable, or 5lead ECG cable, paddles.
• Lead Selection: Displayed on monitor, paddles, I, II, III, AVR, AVL, AVF, V.
• ECG Size: 0.25, 0.5, 1, 1.5, 2, 4 cm/mV display on monitor.
• Heart Rate: 20-300BPM.
• Heart Rate Alarm: On/Off displayed on monitor, user-selectable.
• Smart Alarms: Beeper/voice prompts indicate shock able rhythm.
 
Battery
• Type: Rechargeable, NiMH battery, 12V.
• Operating Time: For a new, fully charged battery: 60 defibrillator discharges at maximum energy, or 3 hours minimum of continuous ECG monitoring. Additional parameters will affect operating   time with different functions
 
SpO2 Module (Options):
• Measurement Range: 30~100%, ±2% between 80%~90%, others ±5%
• Alarm Range: User set high limit and low limit.
• Alarm Accuracy: ±10% within setting values.
• Alarm time Accuracy: less than 12 sec. 
 
 
EtCO2 (Options)
 
NIBP (Options)
 
Recorder
• Paper: 50mm thermal.
• Speed: 12.5mm/sec, 25mm/sec, 50mm/sec.
• Printing Method: High-resolution, thermal print head.
• Print-out Modes: Manual or automatic, user-configurable.
• On/Off Control: Front panel and paddle.
• Automatic Function: 9seconds recording initiated by alarm activation or defibrillator charge or defibrillator discharge.  
 
AED Mode
• AED Function: Auto analyze and charge x3 with programmable auto energy level selection, screen prompts, and voice prompts.
•Shockable Rhythms: Ventricular fibrillation with amplitude >=200uV, ventricular tachycardia with rates >=140bpm, and QRS complex wave duration >=140ms.
• Charge Control:  Control on device front panel, press key on paddle.
• Prompts:  Voice and visual prompts.  
 
Manual Mode
• Energy Selection: Selectable at 2, 5, 7, 10, 20, 30, 50, 70, 100, 150, 200, 300, 360 joules.
•Synchronized Mode: Synchronizes defibrillator pulse to patient's
• R-wave. "SYNC" message displayed on monitor

 