Low Frequency Online UPS Power 80kVA 100kVA 120kVA for CT Scanner with Backup Time 10-300mins

Min.Order: 5
Product origin: Shenzhen, Guangdong, China
Infringement complaint: complaintComplaint
US$ 4000 ~ 10000

Description

Low Frequency Online UPS Power 80KVA 100KVA 120KVA for CT Scanner with backup time 10-300mins

Key Features
1: Humanized display interface
2: Redundant fan design and independent ventilation enhance durable operation under harsh environment
3: Intelligent control of multiple CPU
4: Accept dual-mains input
5: Parallel operation with up to 4 units (option)
6: Variety of communication options available
7: DSP technology guarantees high reliability
8: True online double conversion, equipped with IGBT and output transformer
9: Charging/rectifier/inverter fully digital control technology
10: Intelligent battery management to prolong battery lifecycle
11: Good after-sale services

Technical Specification
LS33 Series 10K - 200Kva
MODELLS33 10KLS33 20KLS33 30KLS33  40KLS33 60KLS33 80KLS33 100KLS33 120KLS33 160KLS33  200K
CAPACITY10KVA /8KW20KVA /16KW30KVA /24KW40KVA /32KW60KVA /48KW80KVA /64KW100KVA /80KW120KVA /96KW160KVA /128KW200KVA /160KW
INPUT
Nominal Voltage3 x 380VAC/400VAC (3Ph + N)
Acceptable Voltage Range305VAC ~ 460VAC
Frequency46-54Hz or 56-64Hz
INVERTER
Nominal Voltage3 * 380VAC/400VAC (3Ph + N)
PrecisionStationary: ±1%
Transitory: ±5% (load variations 100-0-100%)
Frequency50/60 Hz synchronised ±1 % With mains absent ±0.1 Hz
Max. Synchronisation Speed±1 Hz/s
WaveformPure Sinewave
Total Harmonic Distortion (THDv)<2% (Linear Load)
<5% (Non-linear Load)
Phase Displacement120o ±1% (balanced load)
120o ±2% (imbalances 50% of the load)
Dynamic Recovery Time1 cycle at 98 % of the static value
Admissible Overload110% for 10min; 150% for 60sec ; >160% for 200ms
Admissible Crest Factor3:1
Admissible Power Factor0.6~1 (inductive or capacitive)
Imbalance Output Voltage @ 100% Unbalanced Load<1%
Current LimitHigh overload, short-circuit: RMS Voltage Limit
High Crest-Factor current: Peak Voltage Limit
STATIC BYPASS
TypeSolid state
Voltage3 x 380VAC/400VAC (3Ph + N)
Frequency50/60 Hz
Activation CriterionMicroprocessor control
Transfer TimeZero
Admissible Overload150% for 1 hour; 180% for 30sec; >200% for 200ms
Transfer to BypassImmediate, for overloads above 160%
RetransferAutomatic after alarm clear
MAINTENANCE BYPASS
TypeWithout interruption
Voltage3 * 400V (3Ph + N)
Frequency50/60 Hz
Overall EfficiencyLine Mode90%91%92%93%
Battery Mode90%91%93%93%
BATTERY & CHARGER
Battery Type and Numbers12VDC* 16 pcs12VDC * 32 pcs (29~32 pcs adjustable)
Nominal Battery Voltage192 VDC384 VDC (Based on 32pcs batteries)
Charging MethodCC/CV
Precision±1%
Charging CurrentMax.: 40 A
Charging Voltage216 VDC432 VDC (Based on 32pcs batteries)
PHYSICAL
Dimensions, D*W*H(mm)656*405* 817656*405* 941840*432*1140975 *554 *12861200 *910 *16801500 *1140 *1800
Net Weight (Kgs)1802052953304515199501350
* Product specifications are subject to change without further notice
 