Item | Description |
A | AC End Cable (Female), 2m 12AWG Cable |
B | M8*25 screws |
C | DC Extension Cable, 1m |
D | AC Female End Cap, IP67 |
All accessories above are not included in the package, and need to be purchased separately. Please contact our sales representative for the price. (M8 screws need to be prepared by installer-self. |
Component name | Product attributes | Parameter | |
Model | BDM-600 | BDM-300 | |
Input Data(DC) | Recommended Max PV Power (Wp) | 460 x 2 | 380 |
Max DC Open Circuit Voltage (Vdc) | 60 | 60 | |
Max DC Input Current (Adc) | 14x2 | 12 | |
MPPT Tracking Accuracy | >99.5% | ||
MPPT Tracking Range (Vdc) | 22-55 | ||
Isc PV (absolute maximum) (Adc) | 18 x2 | 14 | |
Maximum Inverter Backfeed Current to the Array (Adc) | 0 | ||
Output Data(AC) | Peak AC Output Power (Wp) | 600(continuous) | 250 |
Nominal Power Grid Voltage (Vac) | 240/208/230 | ||
Allowable Power Grid Voltage (Vac) | 211-264 | 183-229 | configurable | ||
Allowable Power Grid Frequency (Hz) | 59.3 a 60.5/configurable | ||
THD | <3% (at rated power) | ||
Power Factor (cos phi, fixed) | >0.99 (at rated power) | ||
Rated Output Current (Aac) | 2.5/2.87/2.6 | 1.04/1.20/1.09 | |
Current (inrush)(Peak and Duration) | 24A, 15us | ||
Nominal Frequency (Hz) | 60/50 | ||
Maximum Output Fault Current (Aac) | 4.4A peak | 2.2A peak | |
Maximum Output Overcurrent Protection (Aac) | 10 | 6.3 | |
Maximum Number of Units Per Branch (20A) (All NEC adjustment factors have been considered) | 7/6/6 | (15A)13 | |
System Efficiency | Weighted Averaged Efficiency (CEC) | 95.50% | |
Night Time Tare Loss (Wp) | 0.11 | 0.08/0.06/0.07 | |
Over/Under Voltage Protection | Yes | ||
Over/Under Frequency Protection | Yes | ||
Anti-Islanding Protection | Yes | ||
Over Current Protection | Yes | ||
Reverse DC Polarity Protection | Yes | ||
Overload Protection | Yes | ||
Protection Degree | IP-67 | ||
Ambient Temperature | -40°F to +149°F (-40°C to +65°C) | ||
Operating Temperature | -40°F to +185°F (-40°C to +85°C) | ||
Display | LED LIGHT | ||
Comunications | Power Line | ||
Dimension (W-H-D) | 10.91"x5.20"x1.97" (277x132x50 mm) | 230*138*35MM | |
Weight | 6.4 Ibs. (2.9 kg) | 4.6 Ibs. (2.1 kg) | |
Environment Category | Indoor and outdoor | ||
Wet Location | Suitable | ||
Pollution Degree | PD 3 | ||
Overvoltage Category | II(PV), III (AC MAINS) | ||
Product Safety Compliance | 1741CSA C22.2No. 107.1I EC/EN 62109-1 I EC/EN 62109-2 | ||
Grid Code Compliance* (Refer to the label for the detailed grid code compliance) | ΙΕΕE 1547 VDE-AR-N 4105 VDE V 0126-1-1/A1 G83/2, CEI 021 AS 4777.2 & AS 4777.3,EN50438 |