  MICC Good quality Transition Junction Style Thermocouple Probes Mineral insulated RTD sensor with thermowell

 



 

Thermocouple
Thermocouple consists of two wires, each made of different metal, welded together at one end. When the welded point(measuring junction) is heated, a thermoelectromotive force is produced that is proportional of the temperature difference between the welded point and the other end (reference junction).
Therefore, by messuring this thermoelectromotive force either with the reference junction temperature kept constant or by using an automatic compensation curciut, the measuring junction temperature can be measured.
The thermoelectromotive force of a thermocouple is independent of the diameter or length of the wire used and depends only on the type of wire used.
 
In this series, the thermocouple is assembled with threaded or flanged protection Wells (with the exception of the TMP14 model), protecting the sensor from the environment and making easier the removal and replacement of the element.

These sets consist of head, nipple with or without head. The nipple allows a minimum distance of the head to the heat source/wall of the process or the isolation, and the union, besides making easier the removal of the sensor, it allows the head to rotate to align the output of the conduit facilitating the cable installation.
 
 The thermocouple can be assembled with analog temperature transmitter, microprocessor with or without communication and protocols (for more information, please feel free to contact us).

 

Technical Data Sheet:

 

 

Type of Thermocouple Core
       Material
       Type
       Leg       core
       material
       Leg dia       JIS C 1602       ANSI
       JIS       ANSI       Max.operating
       temp . In normal
       application(ºC)
       Max.operating
       temp . In overheated
       application(ºC)
       Max.operaring
       temp.(ºC)
       B       +       Platinum 70% + rhodium 30%       0.5       0.5       1500       1700       1700
       -       Platinum 94% + rhodium 6%       0.5       0.5
       R       +       Platinum 87% + rhodium 13%       0.5       0.5       1400       1600       1480
       -       high purity platinum       0.5       0.5
       S       +       Platinum90%+ rhodium 10%       0.5       0.5
       -       high purity platinum       0.5       0.5
       K       +       Nickel 90% + chromiun 10%
       Nickel 95% + Manganese 2%
       +Aluminum 2%
       3.2       3.2       1000       1200       1260
       2.3       1.6       900       1100       1090
       1.6       0.8       850       1050       980
       1       0.5       750       950       870
       0.65       0.32       650       850       870
       E       +
       -
       Nickel 90% +chromiun 10%
       Copper 55%+nickel 45 %
       3.2       3.2       700       800       870
       2.3       1.6       600       750       650
       1.6       0.8       550       650       540
       1       0.5       500       550       430
       0.65       0.32       450       550       430
       J       +
       -
       high purity iron
       Copper 55%+nickel 45 %
       3.2       3.2       600       750       760
       2.3       1.6       550       750       590
       1.6       0.8       500       650       480
       1       0.5       450       650       370
       0.65       0.32       400       500       370
       T       +
       -
       high purity copper
       Copper 55%+nickel 45 %
       1.6       1.6       300       350       370
       1       0.8       250       300       260
       0.65       0.5       200       250       200
       0.32       0.32       200       250       200