Inner dimension | 900L*900D*1050H mm |
Outer dimension | 1350L*1150D*1750H mm |
Turntable diameter | ¢400mm(R200mm is optional) |
Turntable Max. load | 50KG |
Turntable lifting height | 450-750 mm |
Turntable tiltable angle | 0° or 15°(horizontal direction) |
Turntable speed | 1 -5r/min(precise control ) |
Turntable rotate | foreward / Turn back and forth / intermittent rotation |
Testing time | 0-999 min |
Total weight | Appro. 230kg |
IPX12 technology parameter | |
Drip plate area | 600*600mm |
IPX12 Spray aperture diameter (mm) | ¢0.4mm |
Space of Dripping aperture | 20*20 mm |
rainfall precipitation | IPX1=1mm/min IPX2=3mm/min |
Flow adjust | Manual setting |
Drip plate lifting | Fixed |
IPX34 technology parameter | |
Swing pipe radius | R400mm(R200mm is optional |
Swing pipe Flow | IPX3=1.1L/min;IPX4=1.8L/min |
Spray aperture size(mm) | 0.4mm |
Space of Spray aperture | 50mm |
Swing pipe inner diameter(mm) | 15mm |
Swing pipe angle | 240°Turn back and forth 4S,720°Turn back and forth 12S(precise control or custom |
Electric parameter | |
Power Supply | 220V |
Power Supply of samples | 220V |
Power | 1.0KW |
Protective device | Leakage, water shortage, short circuit |
Standards | IEC60529:1989 +A1:1999 +A2:2013Degrees of protection provided by enclosures(IP Code) |