Technical Data Hemodialysis Machine W-T2008-BMain performance of this device:
1. Self-checking function;
2. Carbonate dialysis;
3. Double needle dialysis;
4. Liquid level detector;
5. Bubble detector;
6. Blood leakage detector;
7. Temperature and electric conductivity monitoring;
8. Arterial pressure, venous pressure and transmembrane pressure monitoring;
9. Rolling blood pump;
10. Heparin pump;
11. Dehydration amount controlled by capacity;
12. Automatic disinfection cleaning program;
13. Stand-by power of blood pump in case of power failure;
14. Information display function of display screen.Product DescriptionHaemodialysis Machine (HD)
Be applicable of hemodialysis treatment, hemoperfusion, Plasma Exchange, Pure ultrafiltration project. Touch screen was equipped and it can show Naand UF profiles; In addition, the functions ie. backup power supply, Kt/V, HCO3adjustment, single needle, acetate treatment, pyrogen filter port and net connection ect.are optional.FeatureClinical Application
1. Hemodialysis Therapy
2. Pure ultrafiltration Therapy
3. Hemoperfusion Therapy
4. Plasma exchange Therapy
5. Na+and UF profiling Be applicable for reducing the cases during dialysis treatment such as low/high pressure,muscle convulsion, headache,nausea,vomit ect.
Kt/V function
1.The sufficiency of dialysis can be reflected by Kt/V.
2.HCO3 adjustment function:
3.Be applicable for sericous acid toxicosis patient.
4.Be capable to calibrate the acid toxicosis status according to patient's state of illness.
5.Backup power-supply:
6.It can last for 15-30 minutes after power cut off.specificationMain technical parameter | Volume(length×width×height) | 370mm×340mm ×1570mm |
Weight | about 90kg |
Power supply voltage | AC220V±10% |
Frequency | 50HZ ~ 60 HZ |
Power | 1500W |
Blood pump/spare pump | Flux | 15 ~ 340ml/min (D 6mm) |
| 20 ~ 460 ml/min (D 8mm) |
Heparin pump | Flux | 0.1ml/h~10ml/h(±5%) |
Precise | 0.1ml/h |
Injector size | 20ml/30ml/50ml 10ml/20ml/30ml (selectable) |
Arterial pressure | Display scope | -300mmHg~+300mmHg (±10mmHg) |
Venous pressure | Display scope | -50mmHg~+300mmHg (±10mmHg) |
Dialysate flow | 300ml/min~800ml/min linearity adjustable(+10%)(-5%) |
Temperature | 35.0ºC~39.0ºC |
Resolving rate | 0.1ºC |
Conductivity | 13mS/cm~15.5mS/cm(±0.1 mS/cm) |
UF flow scope | 0~1800ml/h(±30ml/h ) 0~4000ml/h(optional) |
ISO UF flow scope | 0~2000ml/h(±30ml/h) |
TMP | Scope | -100mmHg ~ +600mmHg (±20mmHg) |
Blood leakage monitor | over 1ml blood per liter dialysate (flow:500ml/min) |
Blood level monitor | ultrasonic sensor |
SpeAir bubble monitorInfrared and response threshold value | Single air bubble of 200u I exists when Blood flux is 200ml/min |
Inflow pressure | 0MPa~0.6MPa |
Inflow temperature | 5ºC~30ºC |
Environment temperature | 10ºC~30ºC, Relative humidity≤70% |
Rinse/disinfection | chemical disinfection (citric acid,peracetic acid and oxalic acid) |
Hot rinse | 80ºC |
Back-up power supply | last for 15-30min after electric-cut. |
icati