Specification | ||
MODEL | ASF4880U180-H | ASF48100U200-H |
INVERTER OUTPUT | ||
Rated Output Power | 8,000W | 10,000W |
Max.Peak Power | 16,000W | 20,000W |
Rated Output Voltage | 120Vac(single phase L+N+PE)/ 240Vac(split phase L1+L2+N+PE) | |
Load Capacity of Motors | 5HP | 6HP |
Rated AC Frequency | 50/60Hz | |
Waveform | Pure Sine Wave | |
Switch Time | 10ms(typical) | |
Output Mode | Off-grid(default)/ On-grid / Hybrid | |
BATTERY | ||
Battery Type | Li-ion / Lead-Acid / User Defined | |
Rated Battery Voltage | 48Vdc | |
Voltage Range | 40-60Vdc | |
Max.MPPT Charging Current | 200A | |
Max.Mains/Generator Charging Current | 100A | 120A |
Max.Hybrid Charging Current | 180A | 200A |
PV INPUT | ||
Num. of MPP Trackers | 2 | |
Max.PV array power | 5,500W + 5,500W | |
Max.input current | 22A + 22A | |
Max.Voltage of Open Circuit | 500Vdc + 500Vdc | |
MPPT Voltage Range | 125-425Vdc | |
EFFICIENCY | ||
MPPT Tracking Efficiency | 99.9% | |
Max. Battery Inverter Efficiency | 92% | |
GENERAL | ||
Dimensions | 620*445*130mm(2*1.46*0.4ft) | |
Weight | 27kg(59.5lb) | |
Protection Degree | IP20,Indoor Only | |
Operating Temperature Range | -15~55ºC,>45ºC derated (5~131ºF,>113ºF derated) | |
Cooling Method | Internal Fan | |
Warranty | 2 Years | |
COMMUNICATION | ||
Embedded Interfaces | RS485 / CAN / USB / Dry contact | |
External Modules (Optional | Wi-Fi / GPRS | |
CERTIFICATION | ||
Safety | IEC62109-1, IEC62109-2,UL1741 | |
EMC | EN61000-6-1, EN61000-6-3, FCC 15 class B | |
RoHS | Yes |