1.In microinverter system the solar panels are connected in parallel, without high voltage on the DC side, which has a good safety.
2.The solar panels do not interfere with each other, independent power generation has no short-board effect.The system efficiency can be maximized.
3.In the environment with shadow obscuration,it can shows more efficient conversion efficiency than ordinary on grid string inverters.
4.In the same system, it can be flexibly designed to connect to different power and different types of solar panels.
5.The background can monitor the power generation of each solar panels to reduce maintenance costs.
6.The design service life is 25 years, and the comprehensive investment cost is lower.
Item | Description |
A | AC End Cable (Female), 2m 12AWG Cable |
B | M8*25 screws |
C | DC Extension Cable, 1m |
D | AC Female End Cap, IP67 |
All accessories above are not included in the package, and need to be purchased separately. Please contact our sales representative for the price. (M8 screws need to be prepared by installer-self. |
* Single microinverter connects four PV modules with dual MPPT
* Peak output power up to 1000/1200/1500W; Adapted to 60 & 72 cells PV panels
* Peak efficiency 96.70%; CEC weighted efficiency 96.50%
* Static MPPT efficiency 99.80%; Dynamic MPPT efficiency 99.76% in overcast weather
* High reliability: NEMA6 (IP67) enclosure; 6000V surge protection
Model | HM-600 | HM-700 | HM-800 |
Commonly used module power (W) | Up to 380 (single panel) | Up to 440 (single panel) | Up to 500 (single panel) |
Peak power MPPT voltage range (V) | 29-48 | 33-48 | 34-48 |
Start-up voltage (V) | 22 | ||
Operating voltage range (V) | 16-60 | ||
Maximum input voltage (V) | 60 | ||
Maximum input current (A) | 2x11.5 | 2x11.5 | 2x12.5 |
Maximum input short-circuit current (A) | 2x15 | ||
Maximum backfeed current to array (A) | 0 | ||
Number of MPPTs | 2 | ||
Number of inputs per MPPT | 1 | ||
Rated output power (VA) | 600 | 700 | 800 |
Rated output current (A) | 2.73@220 V 2.61@230 V 2.50@240 V | 3.18@220 V 3.04@230 V 2.92@240 V | 3.64@220 V 3.48@230 V 3.33@240 V |
Nominal output voltage/range (V) | 220/180-275 230/180-275 240/180-275 | ||
Nominal frequency/range (Hz) | 45-55 (under 50 Hz @ 220 V & 230 V) 55-65 (under 60 Hz @ 220 V & 230 V) | ||
Power factor | > 0.99 default 0.8 leading...0.8 lagging | ||
Output current harmonic distortion | <3% | ||
Maximum units per branch | 8@220 V 8@230 V 8@240 V | 7@220V 7@230V 7@240 V | 6@220V 6@230V 6@240V |
Peak microinverter efficiency | 96.70% | ||
CEC weighted efficiency | 96.50% | ||
Nominal MPPT efficiency | 99.80% | ||
Night time power consumption(mW) | <50 | ||
Ambient temperature range (°C) | -40 to +65 | ||
Storage temperature range (°C) | -40 to +85 | ||
Dimensions (W x h x d mm) | 250 x 170 x 28 | ||
Weight (kg) | 3.00 | ||
Enclosure rating | Outdoor NEMA6(IP67) | ||
Cooling | Natural convection (no fans) | ||
Pollution degree | PD3 | ||
Ambient temperature range (°C) | -40 to +65 | ||
Storage temperature range (°C) | -40 to +85 | ||
Dimensions (W x h x d mm) | 182 x 164x29.5 | ||
Weight (kg) | 1.98 | ||
Enclosure rating | Outdoor NEMA6(IP67) | ||
Cooling | Natural convection (no fans) | ||
Pollution degree | PD3 |