ESD5550 Gasoline Engine Governor Generator Speed Control Engine Speed Generator Part
Description:
The PER5550/5570 Series Speed Control unit is an all electronic device designed to control engine speed with fast and precise response transient load changes.(PER5570E is designed for EFC series.)
Isochronous Operation/Steady Stability: +/-0.25% or better
Supply: 12 or 24 VDC Battery Systems(transient&reverse voltage protected)
Power Consumption: 50 ma continuous plus acutator current
Maximum Actuator Current at 25ºC(77ºF): 10 Amps continuous
Technical Data:
Input | Supply | 12 or 24 VDC Battery System (Transient and Reverse Voltage) |
Polarity | Negative Ground (Case Isolated) | |
Power Consumption | 50 ma continuous plus actuator current | |
Actuator Current Range @77°F | Min.2.5 Amps; Max. 10Amps continuous | |
Speed Sensor Signal | 0.5-120 Volts RMS | |
Speed switch Relay | 10 Amps | |
Performance | Isochronous Operation/Steady | ±0.25% or better |
Speed Range/Governor | 1K to 7.5K Hz continuous | |
Speed Drift with Temperature | ±1% Max | |
Idle Adjust CW | 60% of set speed | |
Idle Adjust CCW | Less than 1200 Hz. | |
Droop Range | 1-5% regulation | |
Droop Adj. Max. (K-L | 400 Hz., ±75Hz. Per 1.0A change | |
Droop Adj. Min. (K-L Jumpered) | 15Hz., ±6Hz. Per 1.0A change | |
Speed Trim Range | ±200 Hz | |
Remote Variable Speed Range | 500 - 7.5 Hz. Or any part there of Terminal Sensitivity | |
Terminal Sensitivity J | 100 Hz., ± 15Hz / Volt @ 5.0 K Impedance | |
Terminal Sensitivity L | 735 Hz., ±60 Hz / Volt @ 65 K Impedance | |
Terminal Sensitivity N | 148 Hz., ±10 Hz / Volt @ 1 Meg. Impedance | |
Terminal Sensitivity P | 10 VDC Supply @ 20 ma Max | |
Speed witch adjustment range | 1000-10000HZ | |
Environmental | Ambient Operating | -40 to +180°F(-40°+85 °C) |
Relative Humidity | Up to 95% | |
All Surface Finishes | Fungus Proof and Corrosion Resitant | |
Reliability | Vibration | 1G @ 20 to 100 Hz. |
Testing | 100% Functionally Tested | |
Physical | Dimensions | See outline (FIGURE 1) |
Weigh1 | 1.8 lbs.(820 grams) | |
Mounting | Any position, Vertical Preferred |
Features | Product No | Description | |
ESD2200 Series | * Isochronous Operation | ESD2210-12 or -24 | 12 or 24 VDC / Standard Unit |
* Adjustable PID Functions | |||
* Speed Trim Input | |||
* Hard Potted | ESD2244-12 or -24 | 12 or 24 VDC / Standard Unit | |
ESD5100 Series | * Isochronous, Variable, and Droop | ESD5111 | Multi VDC / Standard Unit |
* Adjustable PID Functions | |||
* Speed Trim Input & Idle Control | ESD5120 | Multi VDC / Light-Force (Low Current) | |
* Auxiliary Input / +10V Supply | ESD5131 | Multi VDC / Selectable Soft Coupling and Lead Circuit | |
ESD5500E Series | * Isochronous, Variable, & Droop | ESD5500E | Multi VDC / Standard Unit |
* Speed Ramping & Starting Fuel | |||
* Soft Coupling & Lead Circuit | |||
* Adjustable Idle Control | ESD5520E | Multi VDC / Light-Force (Low Current) | |
* Auxiliary Input / +10V Supply | ESD5522E | Multi VDC / Light-Force (Low Current) / Enhanced Droop/ Smoke Limiting / Suitable For EFC Forward | |
Acting (Normally Closed) | |||
ESD5221 | * Isochronous, Variable, & Droop | ESD5221 | Multi VDC / Single Element Speed Switch - Overspeed |
* Adjustable PID Functions | |||
* Speed Trim & Idle Control | |||
* Lead Circuit | |||
* Auxiliary Input / +10V Supply | |||
ESD5550/ 5570 Series | * Isochronous, Variable, & Droop | ESD5550 | Multi VDC / Standard Unit |
* Built-In Speed Switch - Overspeed | |||
* Speed Ramping & Starting Fuel | |||
* Soft Coupling & Lead Circuit | |||
*Auxiliary Input / +10V Supply | ESD5570 | Multi VDC / Light-Force (Low Current) | |
ESD5300 Series | ESD5330 | 24 VDC / Standard UnitESD5340 | |
ESD5340 | 24 VDC / Full-Fuel Starting Aid | ||