TVC Thermal Vacuum Chamber/Outer Space Simulation Test Chamber | ||||||
Container way | Horizontal | Vertical | ||||
Model No | TVC-500 | TVC-1200 | TVC-1500 | TVC-2000 | TVC-2500 | TVC-3000 |
Working Diameter(mm) | 500 | 1200 | 1500 | 2000 | 2500~17000 | 3000~17000 |
Working Length(mm) | 1000 | 1500 | 2000 | 3000 | 5000~32000 | 6000~32000 |
No-load Vacuum Limit | 3kPa,1kPa,10Pa,133Pa,0.000001Pa,-0.1MPa,0.001mmHg,0.05Torr,1*10-5Pa,1*10-6Pa,1*10-7Pa,1*10-9Torr,1*10-9mbar | |||||
temperature range /ºC | -190ºC, -160ºC, -150ºC, -120ºC, -100ºC, -80ºC, -70ºC, -60ºC, -40ºC,-20ºC, 0ºC~+150ºC, 200ºC, 250ºC, 300ºC, 400ºC, 500ºC, 600ºC, 700ºC, 800ºC, 900ºC, 1000ºC, 1200ºC, 1400ºC,1600ºC, 1800ºC, 2000ºC, 2500ºC, 3000ºC | |||||
refrigerating method | liquid refrigerant,refrigerating machine,Nitrogen gas temperature,Bath oil temperature | |||||
Infrared heating mode | Infrared heating array,Infrared heating cage | |||||
irradiance | 0W/m2~2200W/m2 | |||||
Irradiation way | solar simulator,Ultraviolet irradiation simulator,Lighting environment simulation system | |||||
power conditions | AC 3Ψ 220V;3Ψ380V; 3Ψ480V+N+G, 60/50Hz |