120kv200kv2ma DC High Voltage Generator

Min.Order: 1
Product origin: Changsha, Hunan, China
Infringement complaint: complaintComplaint
US$ 1200 ~ 2000

Description

120KV200KV2mA DC High Voltage Generator

KDZG-IV intelligent DC high voltage generator adopts intermediate frequency voltage doubling circuit, applies the new PWM intermediate frequency pulse width modulation technology, closed-loop adjustment, adopts the voltage feedback, so that the voltage stability is greatly improved. The high power IGBT device and its driving technology are used, and special shielding, isolation and grounding measures are adopted according to electromagnetic compatibility theory. The DC high voltage generator has high quality, portable, and can withstand rated voltage discharge without damage.

The main components of KDZG-IV series intelligent DC high voltage generator instrument are selected from the United States, Germany, Japan and other countries, so that the instrument is more reliable and stable, the pressure doubling cylinder is small, the capacity is large, the overload capacity is strong, and the field operation test is convenient. Our company regards quality and reputation as life, constantly improve the level of science and technology, and develop high-quality products to meet the needs of users. KDZG-IV intelligent DC high voltage tester is mainly used in power department, mining, metallurgy, iron and steel enterprise power department for zinc oxide arrester, power cables, transformers, circuit breakers, generators and other high voltage electrical equipment DC voltage withstand test or DC leakage current test.
 
120KV200KV2mA DC High Voltage Generator
Product characteristics
KDZG-IV series intelligent DC high voltage generator. By using AIPWM technology, the inaccuracy linearity of PWM technology is adjusted, and the accuracy of the instrument is greatly improved. And use AI technology to set overvoltage protection and overcurrent protection to replace the digital dial switch can only set the voltage value, can not set the current value and voltage drift, maintain the manual 0.75UDC1mA function 1. Automatic zinc oxide arrester DC parameter measurement 2. Automatic oil-immersed transformer measurement function, 3. Automatically print test report and save test report. 4. Manual printing is retained. 5. Increased the voltage, current printing function, 6. Total time T1 and segmented time T2 function. 7. Added perpetual calendar and time function, experiment report with time and date.
 
120KV200KV2mA DC High Voltage Generator
Functional features:
1, the use of new production technology and manufacturing process, citing 0 new PWM high frequency pulse width modulation technology, pulse train logic array modulation, the use of high-power IGBT components, the use of high frequency technology to improve the frequency, the frequency up to 100kHz, so that the output high voltage stability is higher, the Bowen coefficient is smaller.
2, small size, light weight, more beautiful, more reliable, easy to operate, complete functions, easy to use in the field, is currently 0 reliable products.
3, high precision, accurate measurement. Voltage and current are digital display, voltage resolution is 0.1kv, current resolution is 0.1uA. When the instrument is used, there is no need to attach a high voltage measuring instrument, and the digital voltmeter on the control box can directly display the voltage value applied to the load test. The instrument has a high and low voltage end to measure the leakage current, and the high voltage end is displayed by a circular shielded digital meter, which is not afraid of discharge impact and has good anti-interference performance, especially suitable for field use. 4, high stability of voltage regulation, smooth range voltage regulation, output voltage regulation using imported single multi-turn potentiometer, stable booster process, high adjustment accuracy, and designed with coarse and fine adjustment function. The voltage regulation degree is better than 0.1%, the voltage and current measurement error is less than 1.0%, and the pulsation coefficient is better than 0.5%. 5, negative polarity output, zero start, continuous adjustable, over voltage, over current, back to zero, ground protection, special break line protection and other protection functions. The automatic protection circuit has strong function, perfect and reliable protection, so that the operation is safe, and various technical indicators are better than the industry standard and similar products. 6, add a high precision 75%VDC-1mA function, do zinc oxide arrester measurement to bring convenience, gently press without calculation. The control box of the instrument has 75% voltage function key, when doing the lightning arrester zinc oxide test, when the current rises to 1000uA, open the 0.75 button, at this time, the value shown by the voltmeter and ammeter is 75% of the data, after completion, the boost knob should be immediately returned to zero, at the same time, the fine-adjusted voltage knob back to zero, And should immediately press the green button, cut off the high voltage and turn off the power switch. Let's do other tests. 7, convenient overvoltage setting function, using a digital dial switch, the setting voltage value can be visually displayed, so that you can operate more freely, display the value unit is kv. 8, the double pressure cylinder can be used according to the need, flexible and convenient, a multi-purpose machine, economical. 9. The bottom is provided with three built-in support feet, which increases the stability of the pressure doubling cylinder.

Rated voltage (KV)

40 60 60 120 120 120 120 200 200 200 300 300

Rated current (mA)

4 2 5 2 3 5 2 3 5 5 5 2 5 5 5 5 5

Rated power (W)

160 120 300 240 360 600 400 600 1000 600 1500

Voltage measurement accuracy

Digital display meter ± (1.0% reading ±0.2KV)

Current Measurement accuracy

Digital display meter ± (1.0% reading ±2)

Ripple coefficient

≤ 0.5%

Voltage stability

Random fluctuation, power supply voltage change ±10% ≤ 1%

Overload capacity

No-load voltage can exceed the rated voltage by 10% for ten minutes 0 maximum charging current is 1.5 times the rated current

Power supply

single phase AC 50 Hz 220 V ± 10%

Work mode

intermittent use

A continuous time

30 minutes long

Working environment temperature

-10 ~ 40ºC

Relative humidity

not more than 85% at room temperature of 25ºC (no condensation)

Altitude

Below 1500 meters

Tape capacitance

There is no limit to the electrical capacity of the subject

load capacity

can be charged at 1.5 times the rated current

Structure features

epoxy glass steel electrical insulation pressure doubling cylinder

Air insulation, no leakage

Operating box characteristics

High precision 0.75UDC--1mA single touch button (accuracy ≤ 1.0%) 0 Suitable for zinc oxide arrester test

Overvoltage protection adopts dip switch setting, which is clear at a glance

Vertical and horizontal dual-use international standard chassis, more convenient on-site

 