Trkls-100r Open Close Three-Phase Flexible Roche Coil 1200A 333mv 0.4/0.66/0.72kv Current Transformer

Min.Order: 10
Product origin: Nanjing, Jiangsu, China
Infringement complaint: complaintComplaint
US$ 33.99 ~ 199.95

Description
Product Features
 

Split-core structure, easy to install on site and easy to operate. Quick and easy installation or removal without disconnecting the primary cable under test, effective for safe and easy current testing;

Flexible structure design, can detect the current of irregular primary conductor;

Low output voltage, high linearity, wide frequency range, no saturation (without integrator);

The secondary output adopts RJ45 crystal terminal network cable, and the length can be customized according to customer requirements

PERFORMANCE
Working Temperature-40ºC~+70ºCRelative Humidity≤90%
Voltage Level0.4/0.66/0.72KVAccuracy Class1%(with integrator)
Rated Input Current10~2000ARated Output Voltage333mV
Linear Range5%~200%Response Bandwidth1HZ~1MHz
Integrator Power Supply5VDCInsulation Strenth1000MΩ/500V/min
Integrator Load Capacity>10KΩIntegrator with Capacitive Capability≤0.1μF
ShellPC Flame Retardant Grade94-V0Secondary LeadRJ45 Terminal Output
Skeleton and QuiltSilicone RubberIP Protection ClassIP65
 

Shape and Installation Dimensions
ProductRatedRatedPrecisionDimensions(mm)
Model No.InputOutputClassΦ1Φ2
BNWKLS-50R400A333mV0.5
1.0
5010
BNWKLS-80R800A8010
BNWKLS-100R1200A15010
Product Features
 

Split-core structure, easy to install on site and easy to operate. Quick and easy installation or removal without disconnecting the primary cable under test, effective for safe and easy current testing;

Flexible structure design, can detect the current of irregular primary conductor;

Low output voltage, high linearity, wide frequency range, no saturation (without integrator);

The secondary output adopts RJ45 crystal terminal network cable, and the length can be customized according to customer requirements

Scope of Application



      Measurement of high current AC signals (such as short-circuit current); measurement of pulse signals with high peak values (such as lightning current); analysis of harmonic current signals; current measurement of electric welding machines (such as resistance welding); measurement of irregular conductor currents (eg: rail current measurement); instrument measurement, clamp meter transformers (eg: measuring conductors with irregular dimensions).






 