Refrigeration Machinery Condensing Pressure Regulator for Compressor Unit Refrigeration System

Min.Order: 10
Product origin: Ningbo, Zhejiang, China
Infringement complaint: complaintComplaint
US$ 35 ~ 70

Description
Product Description

 

The KVR+NRD pressure regulating system is used to maintain constant and sufficiently high condenser pressure and receiver pressure in refrigeration and air conditioning installations with air-cooled condensers.

KVR can be used with KVD type reservoir pressure regulator


Features

-Realize precise and variable pressure regulation
-Wide application refrigeration capacity and operating range
-Pulsation damping design
-Stainless steel bellows
-Compact angled design, easy to install in any location
-1/4.Schrader valve for pressure testing
-Provide bell mouth interface and outer diameter welding interface in a wide range of sizes
-"sealed" brazed structure
-Can be used for CFC, HCFC, HFC refrigerants


Technical Parameters

Adjustment range: 5~17.5bar Factory setting 10bar           Maximum medium temperature: KVR: 105ºC NRD: 130ºC
Maximum working pressure: KVR: BP=28bar NRD: BP=28bar          Minimum medium temperature: -40ºC
Maximum test pressure: KVR: p'=31bar NRD: p'=36bar
P band
KVR12~22:=6.2bar KCR28~35:=5bar
Opening pressure differential for NRD Start opening: Δp=1.4bar Full opening: Δp=3bar






TYPENominal liquid load Δp=0.2bar       (evaporator load) kwHot gas load Δp=0.2bar                   (evaporator load) kwBell mouth connectionProduct CodeSolder connectionProduct Code
R22R134aR407A/R507R4C7CR22R134aR404A/R507R407Cin.mmin.mm
KVR1250.447.336.654.413.211.61214.31/212034L00911/2 034L0093
    12034L0096
KVR155/816034L00925/816034L0097
KVR22   7/822034L0094
KVR2812912193.7139.334.930.634.937.7   1⅛ 034L0095
 28034L0099
KVR351⅜35034L0100
NRD 1/2 020-1132
 12020-1136
te=-10ºC     tc=+30ºCKVR type regulator is supplied without bell nutbell nut1/212011L1103 
5/816011L1167

When the gas flow velocity at the regulator inlet exceeds 40m/s, flow noise will occur. Therefore, the interface size of the regulator cannot be chosen too small.
 