Equipment technical parameters:
Product model codeBRE-6000-5V/30A/96BRE-6000-5V/60A/48BRE-6000-5V/120A/24BRE-6000-5V/240A/16
Output per channel5V/30A     5V/60A5V/120A5V/240A
Number of channels96,6464,48 32,24,1616,8
Number of parallel units per channel1          2    48
Input power3 phase AC380V ±10%/50Hz
Max input power    18KW   24KW      24KW  24KW
Noise≤65dB
Wiring method of power cabinetThree-phase five-wire connection
Power factor of the whole machine≥0.99 (Load power is more than 30% of full load power)
THD of whole machineTHD≤5%
EfficiencyThe conversion efficiency of each link is greater than 85%
VoltageSetting range0.01V~5V
Min. discharge voltage2V~5V
Measurement range0V~5V
Resolution0.1mV
Control accuracy±(0.02%RD+0.02%FS)
Measurement accuracy±(0.02%RD+0.02%FS)
CurrentRange of charge0.1A~30A0.1A~60A0.1A~120A0.1A~240A
Range of discharge0.1A~30A0.1A~60A0.1A~120A0.1A~240A
Range of Measurement0A~30A0A~60A0A~120A0A~240A
Resolution16 AD,DA
16-bit AD and DA
Control accuracy±(0.05%RD+0.05%FS)
Measurement accuracy±(0.05%RD+0.05%FS)
Temperature drift coefficient25PPM/ºC
PowerMax output power per channel 150W   300W600W1200W
TimeChannel sampling time0.1s
Current response timeMaximum current rise time
Step setting time range1min~1024min
Timer accuracy±0.01%
Step setting methodForm edit (Maximum working steps 128)
Data recordRecording conditionsΔT: 1s~60min
ChargeCharge modeConstant current charging, constant voltage charging, constant current and constant voltage charging, constant power charging, constant resistance charging
Stop conditionsVoltage, current, time, capacity, -ΔV, temperature
DischargeDischarge modeConstant current discharge, constant power discharge, constant resistance discharge
Stop conditionsVoltage, current, time, capacity
LoopNumber of loop1~30000
Step per loop126
Protection methodHardware protectionBattery reverse polarity protection
Short circuit protection
Output voltage surge protection
Protection method Battery voltage double loop measurement protection
Software protectionPower-down data protection
Offline data protection
Lower limit voltage, upper limit voltage, lower limit current, upper limit current, upper limit capacity, upper limit temperature parameter setting protection
Channel featuresDouble closed-loop structure, constant current and constant voltage conversion can transition smoothly, which can effectively prevent the impact of current spikes and large currents on the battery module, and protect the battery module
Channel control modeEach channel can be set and controlled independently
DatabaseUsing SQL, MySQL, ACCESS database to centrally manage test data, compatible with Manufacturing Execution System (MES) for equipment, convenient for data collection of different equipment, delivery of control parameters and debugging and maintenance of communication (database format can be customized according to user requirements)
Data output methodExcel,CSV,TXT,BMP
Curve typeAble to draw the corresponding relationship curves during the formation process of each battery, including voltage/time curve, current/time curve, capacity/time curve, capacity/voltage curve, etc.
Barcode scanningSupport barcode scanning function, which can be realized through battery barcode
The host computer communication methodTCP/IP protocol
Communication interfaceRJ45, 10M~1000M adaptive
System expansionExpand communication through switches and routers
Cabinet typeSuitable for cylindrical, soft bag, square aluminum shell
Cabinet sizeReference size: 800mm×600×1750mm, depending on the specific product
IP protection levelIP20
Equipment working environment requirements:
Index itemindex paramete
temperature(Range of working temperature) -10ºC~40ºC
(Storage temperature range) -20ºC~60ºC
HumidityWorking environment relative humidity<=80% RH (no water vapor condensation)
Storage environment relative humidity<=85% RH (no water vapor condensation)
 
Product model code BRE-6000-5V/300A/8BRE-6000-5V/400A/8BRE-6000-5V/500A/8
Output per channel5V/300A     5V/400A5V/500A
Channel number8   8 8
Number of parallel units per channel8     88
Input power3 phase AC380V ±10%/50Hz
Max input power    15KW   19KW        24KW
Noise≤65dB
 
Wiring method of power cabinet
Three-phase five-wire connection
Power factor of the whole machine 
≥0.99 (Load power is more than 30% of full load power)
THD of wholeTHD≤5%
 EfficiencyThe conversion efficiency of each link is greater than 85%
VoltageSetting range0.01V~5V
Min. discharge voltage2V~5V
Measurement range0V~5V
VoltageResolution0.1mV
Control accuracy±(0.02%RD+0.02%FS)
Measurement accuracy±(0.02%RD+0.02%FS)
CurrentRange of charge0.2A~300A0.2A~400A0.2A~500A
 
Range of discharge0.2A~300A0.2A~400A0.2A~500A
 
Range of Measurement0A~300A0A~400A0A~500A
 
Resolution               16 AD,DA
Control accuracy±(0.05%RD+0.05%FS)
Measurement accuracy±(0.05%RD+0.05%FS)
 Temperature drift coefficient25PPM/ºC
Rate of work   Max output power per channel1500W   2000W2500W
TimeChannel sampling time0.1s
Current response timeMaximum current rise time
Step setting time range1min~1024min
Timer accuracy±0.01%
Step setting methodForm edit (Maximum working steps 128)
Data recordRecording conditionsT:1s~60min
ChargeCharge mode 
Constant current charging, constant voltage charging, constant current and constant voltage charging, constant power charging, constant resistance charging
Stop Voltage, current, time, capacity, temperature
DischargeDischarge modeConstant current discharge, constant power discharge, constant resistance discharge
Stop conditions 
Voltage, current, time, capacity
LoopNumber of loop1~30000
 Step per loop126
Protection methodHardware protectionBattery reverse polarity protection
Short circuit protection
Output voltage surge protection
Battery voltage double loop measurement protection
Software protectionPower-down data protection
Offline data protection
 
Lower limit voltage, upper limit voltage, lower limit current, upper limit current, upper limit capacity, upper limit temperature parameter setting protection
Channel featuresDouble closed-loop structure, constant current and constant voltage conversion can transition smoothly, which can effectively prevent the impact of current spikes and large currents on the battery module, and protect the battery module
 
Channel control mode
Each channel can be set and controlled independently
DatabaseUsing SQL, MySQL, ACCESS database to centrally manage test data, compatible with Manufacturing Execution System (MES) for equipment, convenient for data collection of different equipment, delivery of control parameters and debugging and maintenance of communication (database format can be customized according to user requirements)
 
Data output method
Excel,CSV,TXT,BMP
Curve typeAble to draw the corresponding relationship curves during the formation process of each battery, including voltage/time curve, current/time curve, capacity/time curve, capacity/voltage curve, etc.
 
Barcode scanning
Support barcode scanning function, which can be realized through battery barcode
 
The host computer communication method
Based on TCP/IP protocol
 
Communication interfaceRJ45, 10M~1000M adaptive
 System expansion Expand communication through switches and routers
Cabinet type Suitable for cylindrical, soft bag, square aluminum shell
Cabinet size(L*W*H):800mm×600×1750mm,
Depending on the specific product
IP protection levelIP20
 Equipment working environment requirements:
Index itemindex parameter
temperature-10ºC~40ºC 
Range of working temperature
-20ºC~60ºC 
Storage temperature range