Beryl Battery Testing Machine

Min.Order: 1
Product origin: Foshan, Guangdong, China
Infringement complaint: complaintComplaint
US$ 4500 ~ 5000

Description
Equipment technical parameters:
Product model codeBRE-6000-5V/30A/96BRE-6000-5V/60A/48BRE-6000-5V/120A/24BRE-6000-5V/240A/16
Output per channel5V/30A     5V/60A5V/120A5V/240A
Number of channels96,6464,48 32,24,1616,8
Number of parallel units per channel1          2    48
Input power3-phase AC 380V ±10%/50Hz
Max input power    18KW   24KW      24KW  24KW
Noise≤65dB
Wiring method of power cabinetThree-phase five-wire connection
Power factor of the whole machine≥0.99 (Load power is more than 30% of full load power)
THD of whole machineTHD≤5%
EfficiencyThe conversion efficiency of each link is greater than 85%
VoltageSetting range0.01V~5V
Min. discharge voltage2V~5V
Measurement range0V~5V
VoltageResolution0.1mV
Control accuracy±(0.02%RD+0.02%FS)
Measurement accuracy±(0.02%RD+0.02%FS)
CurrentRange of charge0.1A~30A0.1A~60A0.1A~120A0.1A~240A
Range of discharge0.1A~30A0.1A~60A0.1A~120A0.1A~240A
Range of Measurement0A~30A0A~60A0A~120A0A~240A
Resolution16-bit AD and DA
Control accuracy±(0.05%RD+0.05%FS)
Measurement accuracy±(0.05%RD+0.05%FS)
Temperature drift coefficient25PPM/ºC
PowerMax output power per channel 150W   300W600W1200W
TimeChannel sampling time0.1s
Current response timeMaximum current rise time
Step setting time range1min~1024min
Timer accuracy±0.01%
Step setting methodForm edit (Maximum working steps 128)
Data recordRecording conditionsΔT: 1s~60min
ChargeCharge modeConstant current charging, constant voltage charging, constant current and constant voltage charging, constant power charging, constant resistance charging
Stop conditionsVoltage, current, time, capacity, -ΔV, temperature
DischargeDischarge modeConstant current discharge, constant power discharge, constant resistance discharge
Stop conditionsVoltage, current, time, capacity
LoopNumber of loop1~30000
Step per loop126
Protection methodHardware protectionBattery reverse polarity protection
Short circuit protection
Output voltage surge protection
Protection methodHardware protectionBattery voltage double loop measurement protection
Software protectionPower-down data protection
Offline data protection
Lower limit voltage, upper limit voltage, lower limit current, upper limit current, upper limit capacity, upper limit temperature parameter setting protection
Channel featuresDouble closed-loop structure, constant current and constant voltage conversion can transition smoothly, which can effectively prevent the impact of current spikes and large currents on the battery module, and protect the battery module
Channel control modeEach channel can be set and controlled independently
DatabaseUsing SQL, MySQL, ACCESS database to centrally manage test data, compatible with Manufacturing Execution System (MES) for equipment, convenient for data collection of different equipment, delivery of control parameters and debugging and maintenance of communication (database format can be customized according to user requirements)
Data output methodExcel,Txt
Curve typeAble to draw the corresponding relationship curves during the formation process of each battery, including voltage/time curve, current/time curve, capacity/time curve, capacity/voltage curve, etc.
Barcode scanningSupport barcode scanning function, which can be realized through battery barcode
The host computer communication methodTCP/IP protocol
Communication interfaceRJ45, 10M~1000M adaptive
System expansionExpand communication through switches and routers
Cabinet typeSuitable for cylindrical, soft bag, square aluminum shell
Cabinet sizeDepending on the specific product
IP protection levelIP20
Equipment working environment requirements:
Index itemindex parameter
temperatureRange of working temperature
-20ºC~60ºC
Storage temperature range
HumidityWorking environment relative humidity<=80% RH (no water vapor condensation)
Storage environment relative humidity<=85% RH (no water vapor condensation)
Product Tag: