0.4kVA-1200kVA High Low Frequency Online Offline Inverter Double Conversion Home Battery Uninterruptible Tower Mounted Power Supply UPS

Min.Order: 10
Product origin: Fuzhou, Fujian, China
Infringement complaint: complaintComplaint
US$ 450 ~ 500

Description
UB series power supply adopts online double conversion design and digital control technology and it features high input and output power factor(0.9). With ECO mode for energy-saving, intelligent battery management and excellent network management, it is a cost-effetive power solution for your critical devices. When UPS is on battery mode, it can shut down unnecessary load and extend the backup time of the critical load.
General Features
True double-conversion
Digital control guarantees high reliability
ECO mode operation for energy saving
Output receptacle control for non-critical load shedding capability
Emergency power off function(EPO)
Generator compatible
Communications:RS-232,USB,SNMP card(Optional), Relay card (Optional)
Bypass can be used when UPS is off(Setted in LCD)
Cold start

 Technical Specification 
Technical Specification
MODELUBUBUBUBUBUBUBUBUBUBUBUBUBUB
10-241010L1515L20-482020-9620L20L-963030-9630L30L-96
Capacity1000VA/900W1500VA/1350W2000VA/1800W3000VA/2700W
(VA/Watts)
INPUT 
Nominal Voltage 208/ 220/230/240Vac(L+N+PE)
Operating
Frequency Range
110~300Vac @(0~60%) Load;120~300Vac @(60~70%)Load,140~300Vac @(70~80%)Load;
160~300Vac @(80~100%)Load
Operating Frequency Range50Hz:45~55Hz,60Hz: 55-65Hz  Auto Sensing
Power Factor > 0.85@25%Load;>0.95 @50%Load;>0.97@75%Load;>0.99 @ Nominal voltage& 100%Load
OUTPUT 
Output Voltage208/220/230/240Vac:230Vac(Default)
Power Factor0.9
Voltage Regulation±1%
FrequencySynchronized45-55Hz ±0.02Hz@ 50Hz, 55-65Hz ±0.02Hz@60Hz
 Range
Battery Mode &None  (50/60±0.02)Hz
Synchronized Range 
Crest Factor3:1
Harmonic Distortion≤3% with linear load
(THDv)≤5% with non-linear load 
Waveform Pure Sinewave
Transfer TimeUtility to Battery : 0ms; Utility to Bypass: 4ms(Typical)
EFFICIENCY
AC Mode88%88%89%90%
Battery Mode84%85%85%85%86%87%
ECO Mode>93%>94%
BATTERY
Battery Type12V/9AH12V12V/9AH12V12V/9AH12V/7AH12V12V/9AH12V/7AH12V
Numbers233*N33*N4686*N8*N686*N8*N
Maximum16.0/12.016.0/12.016.0/12.016.0/12.0
 Charging
 Current (A)
Charging27.4V±1%41.1V±1%41.1V54.8±1%82.2V±1%109.6V±1%82.2V±1%109.6V±1%82.2V±1%109.6V±1%82.2V±1%109.6V±1%
 Voltage(Vdc)±1%
ProtectOver-voltage(14.7v) /Low-voltage(10v)
PROTECTION
Overlo ad Line Mode105%-150%, 30s turn to bypass mode ; >150% 300ms turn to bypass mode
CapacityBattery Mode105%-150%, exceed 30s shutdown ;  >150% exceed 300ms shutdown
INDICATORS
LED & LCD DisplayLoad/Battery/Input/Output/Operating Mode Information
ALARM
Battery ModeSounding every 4 seconds 
Battery LowSounding every second
OverloadSounding every 0.5 second
FaultContinuously Sounding
MANAGEMENT
Smart RS-232/USBExternal Modbus card supported by RS232,Software supports Windows Family,Linus,FreeBSD
(Preferential)
Intelligent SlotSNMP (Standard or mini) independent to RS-232(Optional)
ENVIRONMENT
Operating Temperature0ºC~40ºC
Humidity Range0~95% (Non-condensing)
Altitude< 1500m
Noise Level<50dB@ 1Meter
PHYSICAL
Dimension144×400×215191×468×337
 W×D×H (mm)
Net Weight (kg)11.313.75.913.96.221.926.929.610.610.827.430.111.111.3
STANDARDS
Safety IEC/EN62040-1
EMCIEC/EN62040-2

 