Siemens Lgb22.330A27 Gas Burner Controller Temperature Control Box

Min.Order: 1
Product origin: Shenzhen, Guangdong, China
Infringement complaint: complaintComplaint
US$ 307 ~ 312

Description

Siemens LGB22.330A27 Gas Burner Controller Temperature Control Box

OVERVIEW
   The LGB... are designed for use with gas burners of small to medium capacity, with or without auxiliary fan, in intermittent operation*.
The gas burner controls are tested to EN298 and CE certified in compliance with the directives for gas-fired appliances and electromagnetic compatibility.
PRODUCT PARAMETERS
NameBurner Controller
BrandSiemens
ModelLGB22.330A27
OriginGerman
Deliver Time2~15 days
Mains voltage220 V -15 %...240 V +10 %
Degree of protectionIP40
Mains frequency50 Hz -6 %...60 Hz +6 %
 
Features At a Glance
 
The burner controls LGB... are used for the startup and supervision of single- or two stage gas or gas / oil burners having a capacity of up to 350 kW in intermittent operation. The flame is supervised with either an ionization current detector electrode, a blue flame
detector QRC1... for forced draught gas / oil burners, or a UV detector QRA... (with auxiliary unit AGQ1...), depending on the type of burner control used.
When used with the appropriate adapters, these burner controls replace their
predecessors LFI7..., LFM1... and LFD... in terms of function and size (please also refer
to «Replacement types» under «Ordering»). Other application-related features:
- Detection of undervoltages in compliance with the respective standards
- Air pressure supervision with functional check of the air pressure monitor during startup and operation
- Possibility of electrical remote reset
- Burner controls LGB41... for use with atmospheric gas burners.
 

 

WARNING

1,Do not install it in the following places
(1)Places where special drugs or corrosive gases are present (e.g. ammonia, sulfur, hydrochloric acid, ethylene compounds, etc.)
(2)Places where water drops or is too wet.
(3) High temperature places.
(4) A place where the vibration lasts for a long time.
2, Please connect according to the specified basis.
3, In order to prevent electric shock and meter damage, please connect the power supply last. Misunderstanding that touching other subterminals can cause accidents and damage to the meter.
4,The load of each terminal connection should not exceed the rated value.
5,Please use the power supply with the same voltage and frequency as indicated by the machine.
6,For timers and auxiliary relays used as additional functions, please select reliable products and correctly form loops according to your needs.
7,Please ground according to the standard above D type grounding specified in the electrical equipment technical standard, and be sure to ground the burner body.
8,Do not tie the power cord and the high-voltage cable of the ignition transformer with the wire of the flame monitoring rod, and do not put it in the same wire tube, please wire separately.In particular, the high-voltage cable should be distributed separately, 10 cm away from the burner controller Above.
9,Please connect the ignition transformer high-voltage cable reliably to ensure that there is no bad contact. Poor contact will produce high frequency waves, radio noise, etc., causing misoperation. In addition, install the ignition transformer directly with the burner body or the metal part electrically connected to the burner body.
10,After connecting cables, ensure that the cables are correctly connected. Incorrect wiring may damage the unit or cause incorrect actions.