ASTM D 4737- 03 Diesel Cetane Measurement Model SX-150


Whether in the field or in the laboratory,this analyzers are leaders in portable rapid analysis instruments. We designs and produces analytical instruments for gasoline, diesel, motor oil and transformer oil.

Portable octane and cetane analyzers are often used for on-site analysis of octane number of power gasoline, corresponding to the motor method and research method (RON and MON), and also suitable for cetane number analysis of diesel. In addition, the temperature of the analyzed liquid and the freezing point of diesel can also be measured, and the measurement results are displayed on the LCD liquid crystal display.

Octane and cetane analyzer is widely used all over the world. Its measurement method conforms to international standards: octane measurement conforms to: ASTM D 2699-86, ASTM D 2700-86; diesel cetane measurement conforms to: ASTM D 4737- 03, ASTM D 613, EN ISO 5165.



1.TP-225 consists of standard color disc, observation optical lens, light source, colorimetric tube.
2.Take the inside-frosted bulb of 220V / 100W and color temperature 2750 ± 50K as standard light source. After Source light color filter through the milky glass and sunlight filter glass, the spectral characteristics of the resulting standard light similar to North Light.

3.The light of petroleum products Chroma tester through the filter, then form two parallel beams, their size and shape are exactly the same, uniformly irradiated on the sample of color glass in standard color wheel and sample colorimetric tube, and through the prism and lens reflex, then enter into the eyepiece.

4.There are 26 Φ14 light holes, of which 25 were 1-25 sequence containing color number standard color glass sheet, the twenty-sixth is blank, the color wheel on the right side hole, so that the operator selects the correct standard corresponding color when toggle the standard color wheel, and compares the standard color in standard color wheel and color of samples in color tube.

               
#Parameter descriptionMeasurement unitsValue
1Measured petrols octane numbers rangeON40-135
2Acceptable limit of octane number measurement basic error, maxON±0.5
3Limit of acceptable difference between parallel octane number measurements, maxON±0.2
4The determination range of antiknock additives content in petrols%0.5-15
5Acceptable basic error limit of antiknock additives content determination in petrols%0.1
6Petrol oxidation breakdown time measurement rangeMin50-2400
7Acceptable basic error limit of petrol oxidation breakdown time%5
8Petrol quality determination mode basing on volume resistivity
Ohm
10 6-10 14
9Acceptable basic error limit of volume resistivity measurements
%
3
10Cetane numbers measurement rangeCN20-100
11Acceptable basic error limit of cetane numbers, maxCN±1.0
12Acceptable difference limit between cetane numbers parallel measurements, max
CN

± 0.5
13Acceptable error limit when determining diesel-fuel pour pointºC2
14Kerosine content determination range in summer diesel fuels%0-50
15Acceptable basic error limit when determining kerosene content in diesel fuels
%

3
16Mode for pour point depressants content determination for diesel fuel%0.2-1
17Acceptable basic error limit when determining of pour point depressants content%0.01
18Motor oils clarity level measurement range%50-100
19Acceptable error limit of motor oils clarity level measurement%0.1
20Acceptable difference limit between motor oils clarity parallel measurements%0.01
21POL dielectric permeability measurement rangeunits1-5
22Acceptable error limit of dielectric permeability measurement, maxunit0.001
23Acceptable difference limit between POL dielectric permeability parallel measurements, maxunit0.001
24Oils base number determination rangeunit3-24
25Acceptable basic error limit when determining oils basic numberBN unit1
26Motor oils manufacturer and brand determinationManufacturer-
27Circuit-breaker oils (dielectrics) breakdown voltage measurement rangekV5-100
28Acceptable error limit of circuit-breaker oils breakdown voltage measurement, maxkV1
29Acceptable difference limit between circuit-breaker oils breakdown time parallel measurements, maxkV0.2
30Measurement range of circuit-breaker oils loss angle tangent%0.01-40
31Acceptable error limit of circuit-breaker oils loss angle tangent, max%0.01
32Acceptable difference limit between circuit-breaker oils loss angle tangent parallel measurements, maxunits0.001
33Determination range for mechanical impurities content in oil products%97-100
34Acceptable basic error limit when determining mechanical impurities content in oil products%0.01
35Water-in-oil content determination range for oil products%0-30
36Acceptable basic error limit when determining water-in-oil content of oil products%1
37Measurement timesec1-5
38Insufficient power supply indication operation thresholdV5.4
39Instrument useful life 6
40Overall dimensions of:  
 electronic modulemm100х210х40
 sensor #1 and #2mm60х100
 Instrument mass with one sensor/two sensorsg850 / 680
                                                                                           



 
MOQ1 Set
Trade TermsEXW, FOB, CIF, CFR
Payment TermsT/T, L/C
Port of LoadingAny Port of China
Packing MethodInternaional Standard Wooden Case
Transportation MethodBy Sea, By Land, By Air, By Express
Supply Capability100 Sets/Month

 





☎ Exhibition

Welcome to visit our website, welcome your inquiry.

Welcome to visit our website, welcome your inquiry.

Scroll to Top