Common installation methods of RFID laundry labels:
1) Method 1: directly sew to the cloth or clothing;
2) Method 2: sew or install the bag into the cloth, and then sew the bag onto the cloth grass;
Advantages: After the cloth reaches the washing life, the bag can be cut off and installed on the new cloth, so that the label can be reused to reduce the single use cost of the label;
Disadvantages: More installation time.
3) Method 3: directly press the label on the cloth (contact the manufacturer to explain the requirements for ironing conditions before ordering in this way).
Introduction to RFID laundry label parameters:
1.1 Specification description
Air protocol: EPC Class1 Gen2; ISO18000-6C
Operating frequency: 860-960MHz (the frequency can be customized as required)
Chip type: U8 chip (can be customized according to different chips)
Chip storage: EPC 128 bits TID 48 bits
TID: TID 48 bit, TID is globally independent and cannot be modified
Reading and writing performance: readable and writable (customers can repeatedly write content to the chip 100000 times)
Data preservation: 10 years
Product service time: 2 years or more than 200 times of washing
Materials for product application: flexible textiles
Product weight: 98g/100 pieces of glue; No glue 85g/100 pieces
Product form: single
RoHS: RoHS compliant
Product color: white (other colors can be customized)
1.2 Product dimensions
Overall size (length * width * thickness): 70x15mm (thickness at chip position is 1.8 ± 0.2) (other sizes can be customized)
1.3 RF performance
Fixed reader writer: (installed on dry towel) more than 3.0 meters (4W EIRP)
(Installed and wrapped in single-layer and multi-layer wet towels) more than 1.2m (4W EIRP)
Handheld reader writer: (installed on dry towel) more than 2.0m
(Installed and wrapped in single-layer and multi-layer wet towels) more than 0.8m
Polarization mode: linear polarization
Consistency test: passed the consistency test of Voyantic, Finland
1.4 Reliability
Operating temperature: - 25 ºC~70 ºC
Ironing temperature (at 4bar pressure): 85 ° C @ 60 minutes, 120 ° C @ 10 minutes, 150 ° C @ 4 minutes, 180 ° C @ 10 seconds
Humidity: 8~100% RH
High and low temperature alternating test: 7 high and low temperature alternating cycles from - 40 ° C to+150 ° C, passed the test for 2 consecutive days
1.5 Optional
Pre write: Supported
Customized product appearance and color: support (more than 200000)