AC Charging Input Parameters | |||||
Parameters | Minimum | Standard | Maximum | Unit | Note |
AC Input Charging Power | 1600 | W | |||
Input Voltage Range | 88 | 120 | 144 | Vac | 120V Version |
176 | 220 | 264 | Vac | 220V Version | |
Input Frequency | 50/60±3 | Hz | |||
Input Current | 17 | A | 120V Version | ||
10 | A | 220V Version | |||
Input Surge Current | 20 | A | 120V Version | ||
15 | 220V Version | ||||
Power Factor | 0.98 | Rated Input,>30% load power | |||
Input Overvoltage | 148 | Vac | 120V Version Hysteresis 4Vac Self recovery | ||
268 | Vac | 220V Version Hysteresis 4Vac Self recovery | |||
Input Undervoltage | 84 | Vac | 120V Version Hysteresis 4Vac Self recovery | ||
172 | Vac | 220V Version Hysteresis 4Vac Self recovery |
DC Charging Output Parameters | |||||
Parameters | Minimum | Standard | Maximum | Unit | Note |
Output Power | 1500 | W | |||
Output Voltage Range | 33.6 | 48 | 51 | Vdc | |
Output Voltage Accuracy | ±0.2 | Vdc | |||
Output Current Range | 32 | A | |||
Output Current Accuracy | ±0.5 | A | |||
Software output overvoltage | 51.24 | Vdc | |||
Hardware output overvoltage | 51.3 | Vdc | Hardware overvoltage is not recoverable | ||
Ripple(Peak) | 220 | mV | Add a 0.1uF film capacitor to the rated input/output | ||
Output overcurrent protection | 32 | A | 3 consecutive protection locks within 1 minute, power off, and recovery |
AC Discharging Output Parameters | |||||
Parameters | Minimum | Standard | Maximum | Unit | Note |
AC Output Power | 2200 | 4000 | W | 2400W for 1.5min, peak 4000W (3S) | |
Output Voltage Range | 100 | 120 | 130 | V | Vac |
200 | 230 | ||||
Output Frequency | 50/60 | Hz | Communication setting 50Hz/60Hz | ||
Output Current RMS | 25 | 45.8 | A | 100V Version | |
10.5 | 17.4 | 220V Version | |||
Output Voltage Harmonics | 3 | % | Rated output full load (R load) | ||
Efficiency | 92.5 | 93 | % | Rated Load | |
Start Time | 3 | 5 | S | Press the inverter output button until the output has a voltage | |
Load loss | 25 | W | Rated output no load | ||
Output Overvoltage | 140 | V | 120V Version | ||
250 | V | 220V Version | |||
Overload Protection | 2200 | W | 3min shutdown output | ||
4000 | W | 3s shutdown output | |||
Short Circuit Protection | 75.0 | A | Appears 3 times in a minute without restarting |
DC Discharging Input Parameters | |||||
Parameters | Minimum | Standard | Maximum | Unit | Note |
Input Power | 2160 | 4000 | W | Peak 4000W (3S) | |
Input Voltage Range | 34.8 | 48 | 50.4 | Vdc | |
Input Current Range | 45 | 62 | A | Peak 120A (3S) |
S/N | Specification | Parameters | Note |
1 | Continuous output max power | 2200W | |
2 | Peak Power | 4000W(3S) | |
3 | Battery | Graphene all-solid-state battery | |
4 | Battery Capacity | Host + Auxiliary 3000wh (Maximum) | |
5 | Charging Mode | Fast charging mode: 1600W/solar: 600W | |
6 | Solar Energy | 12V input | |
7 | Cycle Life | Over 3000 times (80%) | |
8 | Working Environment | -20ºC-- 60ºC | |
9 | Protect Function | Protection against overvoltage, overtemperature, overload, over-discharge, and AC short circuit. | |
10 | Humidity | 45%-85%RH | |
11 | Conversion Efficiency | 88-92% | |
12 | Single-cell battery overcharge protection voltage | 4.25V | |
13 | Single-cell battery over-discharge protection voltage | 2.8V | |
14 | Temperature Protection | Inverter heat dissipation, 85ºC | |
15 | Output short circuit | Short circuit protected |
S/N | Testing Project | Parameters | Unit | Note |
1 | Working Environment | -20~60 | ºC | |
2 | Storage Environment | -30~70 | ºC | |
3 | Humidity | 45%~85% | RH | |
4 | Cooling Type | Air-cooled | Cooling≥45ºC | |
5 | MTBF | ≥5000 | H |
S/N | Description | Quantity |
1 | Host | 1 |
2 | Auxiliary | 1 |
3 | AC Charging Cable | 1 |
4 | 600W Solar Panel (Optional accessories) | 1 |
5 | Solar Energy Cable (Optional accessories) | 1 |
6 | Product instruction manual and warranty card | 1 |
Gross Weight(kg): Host 14.5kgs, Auxiliary 7kgs; Size(mm): Host 335*2699*260, Auxiliary 335*269*160; Qty(pc): One power supply per box |