Top Rated Lab Optical Instrument Single Beam UV Vis Spectrophotometer for Sale

Min.Order: 1
Product origin: Zhengzhou, Henan, China
Infringement complaint: complaintComplaint
US$ 728 ~ 836

Description

Product Description

Chemical Laboratory Portable Digital UV-VIS Spectrophotometer with USB Interface
752N Plus UV-VIS Spectrophotometer has the holographic blazed grating monochromator has the advantages of high wavelength accuracy, good monochromaticity and low stray light.

752N Plus UV-VIS Spectrophotometer has the holographic blazed grating monochromator has the advantages of high wavelength accuracy, good monochromaticity and low stray light.
1. 7-inch multi color touch-screen, good human-computer interface. 
2. Linear regression method and coefficient method are added to the concentration test method. 
3. USB interface is added, and large capacity memory can store 30 concentration curves.
4. Adopt microcomputer measurement system, with high conversion accuracy of T-A, automatic adjustment of 
5. 0% T and 100% T, concentration factor setting and concentration direct reading.
6. High accuracy, Good Reproducibility and Stability of Measurement Readings.
7. Automatic light gate technology, No need blackbody, to protect the photoelectric sensor

Detailed Photos

Product Parameters
Model / Photometry: 752N Plus / Split Beam UV Vis Spectrophotometer
 
Monochromator Type:Czerny-Turner
 
Focal Length: 160mm
Grating:   1200 lines/mm
Detector: Silicon Photocell
 
Spectrum Bandwidth:  2nm
Wavelength Setting:  Manual Turn Knob
Wavelength Range:  200-1000nm
Wavelength Accuracy:±2nm
 
Wavelength Repeatability:  ≤1nm
 
Stray Light  : ≤0.1%T( at 220nm NaI, 360nm NaNo2 )
Photometric Range: 0.0-200.0% T
-0.097-4.000 A
0.000-9999 C
Photometric Accuracy:±0.5% T
 
±0.004 Abs (0-0.5A)
 ±0.008 Abs (0.5-1A)
 
Photometric Repeatability:≤0.2% T
 
 0.002 Abs (0-0.5A)
 
0.004 Abs (0.5-1A)
 
Noise:  100%(T)noise≤0.3%(T) , 0%(T)noise≤0.2%(T)
Power:  AC220V±22V 50Hz±1Hz, 120W
Instrument Size& Weight580mm X 460mm X 345mm 0.1M3 16.5kg
Related Products
metering mode the proportion of dual-beam
Monochromator Czerny - Turner
Focal length 160mm
Grating 1200 lines / mm
Detector photocell
Spectral bandwidth 2nm
Wavelength setting Touch screen input
Wavelength range 190 - 1100nm
Wavelength Accuracy ± 0.5nm
Wavelength repeatability ≤ 0.2nm
wavelength scanning speed fast, medium and slow (limited to S models)
Light source switching wavelength 340nm
Stray light ≤ 0.03% (T) (measured at Nil in 220 nm) (measured at NaNO2 at 360 nm)
Photometric range:0.0 ~ 200.0% T
-0.301 ~ 4.000A
0.000 to 9999C
Photometric accuracy:± 0.3% T
± 0.002Abs (0 - 0.5A)
± 0.004Abs (0.5 - 1A)
 
Photometric repeatability:≤ 0.15% T
0.001Abs (0 - 0.5A)
0.002Abs (0.5 - 1A)
 
Baseline flatness:≤ ± 0.002A (200nm ~ 1090nm) (limited to S)
Noise:0.15% T
Baseline drift:± 0.0009Abs / 0.5h (limited to S) (after 2h boot, 250nm and 500nm)
metering mode double beam
Monochromator Czerny - Turner
Focal length 200mm
Grating 1600 lines / mm
Detector photocell
Spectral bandwidth 2nm
Wavelength setting Touch screen input
Wavelength range 190 - 1100nm
Wavelength Accuracy ± 0.3nm
Wavelength repeatability ≤ 0.1nm
Wavelength scanning speed fast, medium and slow
Light source switching wavelength 340nm
Stray light ≤ 0.02% (measured by NaI at 220 nm) (measured at NaNO2 at 360 nm)
Photometric range:0.0 ~ 200.0% T
-0.301 ~ 4.000A
0.000 to 9999C
Photometric accuracy:± 0.3% T
± 0.002Abs (0 - 0.5A)
± 0.004Abs (0.5 - 1A)
Photometric repeatability:≤ 0.15% T
0.001Abs (0 - 0.5A)
0.002Abs (0.5 - 1A)
Baseline flatness:≤ ± 0.0008A
Noise:0.1% T
Baseline drift:± 0.0004 (A / h) at 250nm and 500nm (preheat for 2 hours)
Power supply voltage:AC220V ± 22V 50Hz ± 1Hz
Power:200W
 
Model N8
Metering mode double beam
Monochromator Czerny - Turner
Focal length 200mm
Grating 1600 lines / mm
Detector photocell
Spectral bandwidth 2nm
Wavelength setting Touch screen input
Wavelength range 190 - 1100nm
Wavelength Accuracy ± 0.3nm
Wavelength repeatability ≤ 0.1nm
Wavelength scanning speed fast, medium and slow
Light source switching wavelength 340nm
Stray light ≤ 0.02% (measured by NaI at 220 nm) (measured at NaNO2 at 360 nm)
Photometric range 0.0 ~ 200.0% T
-0.301 ~ 4.000A
0.000 to 9999C
Photometric accuracy ± 0.3% T
 ± 0.002Abs (0 - 0.5A)
± 0.004Abs (0.5 - 1A)
Photometric repeatability ≤ 0.15% T
  0.001Abs (0 - 0.5A)
 0.002Abs (0.5 - 1A)
Baseline flatness ≤ ± 0.0008A
Noise 0.1% T
Baseline drift ± 0.0004 (A / h) at 250nm and 500nm (preheat for 2 hours)
Power supply voltage AC220V ± 22V 50Hz ± 1Hz
Power 200W

 

Packaging & Shipping

Company Profile

FAQ

Q1: Why Choose NANBEI ?
(1).Professional manufacturer with more than 13 years experience
(2).Exported to more than 97% Countries
(3).Turnkey Solution is no problem

Q2:OEM,ODM acceptable or not?
Absolutely Yes

Q3:What's kind of Payment terms for customer choosing?
T/T ,Western Union, Money Gram , Credit Card, Paypal , L/C ...

Q4:Can we visit your factory online?
Absolutely no problem

Q5:Can online video inspection before shipment?
Absolutely no problem

Q6: what's the MOQ ? Sample order is OK?
MOQ:1 set, sample order is no problem

Q7:What's kind of shipment for customer choosing?
Usually ship by sea, by air, by international express.
We can also provide reasonable solutions according to your transportation requirements

Q8:How to ensure product quality and after-sales service?
We have CE, ISO quality certificate, and SGS authentication.

After-sale service:
1.Warranty:1 year
2.We supply free part for quality problem in warranty
3.Long life technical support and service


Product Tag:
Related categories:
Scroll to Top