Magnetic floating fuel level sensor consists of reed, precise resistance and amplification transformation circuit and adopt imported advanced sensor componentsand signaltransmitters.When the magnetic lineof themagnetic float ball reaches a certainplace ofthe levelsensor, the reed closes, andthe floatball changeswith theheight of level interface.The amplification transformation circuit converts the change of the interface height into linear 4~20mADC signal to realize the measurementand transmissionof thelevel locationsignal.
Measuring range | 200~6000mm(>6M customize) |
Resolution factor | 10mm,5mm,20mm |
singal output | 4~20mA(two-line) 2000/m(1/2",3/8") |
Loading resistance | 500Ω |
Transmitting | >1000m |
Working power supply | 16~30VDC |
Density | ≥0.5g/cm3 |
Pressure | PN2.5~PN160(×0.1MPa)(Max pressure PN320) |
Operating temperature | -40 ~ 80 °C, ≤120 °C, ≤150 °C |
Float ball diameter | Φ30~Φ120(depending on pressure and density) |
Flange installation | DN40~DN150/RF/PL(HG/T20592~2009) customize 2'' thread(downward install) 1/2'' thread (upward install, resistance signaloutput) 3/8'' thread(upward install, resistance signal output) |
Installation angle | ≤±25° |
Electrical connection | M20×1.5 female thread Three-lines screening cable |
IP grade | IP65 |
Explosion-proof grade | Exia II CT6Ga,EXd IICT6Gb |