Mini Electric Ball Valve
Compact design and light weight, small electrical actuator with fail-safe function (NC/NO) | INSTRUCTION FOR MANUAL OVERRIDE |
It is only permitted to use when power-off |
| Lift the hand-wheel,and turn it left or right until the valve is in place |
When the black line on the indicator is horizontal,the valve is on;when vertical,the valve is off |
Press down hand-wheel after using manual override in order to work properly when power-on |
CE | IS09001 | | EC |
FEATURES | APPLICATION |
Mini dimension suit for small equipment | HVAC |
Patented technology-floating seal structure | Water treatment |
Long service life:80000 to 100000 cycles | Chemical process |
Low working current,suitable for battery driving | Small equipment for automatic Control |
Manual override and position indicator | Replacing solenoid valve,
particularly when solenoid can't
work reliably |
Metal gearbox and POM gear |
High flow capability |
| PARTS | MATERIAL |
| |
| Actuator
housing | ABS |
|
Valve body | Brass/SS304 |
Valve ball | Brass/SS304 |
Stem | Brass/SS304 |
Ball seat | PTFE |
| | Seal | SILASTIC(Q) |
TECHNICAL PARAMETERS |
Series | Max
torque | Operating
time | Working
voltage | Max
power | Enclosure | Max
pressure | Medium
temperature | Ambient temperature |
FH-MO | 2.5N,m | <5sec<> | DC3-V | <5w<><5sec<> | IP65 | 1.0Mpa | 0-90ºC | -20ºC |
AC/DC9-24V |
<5w<><5sec<><5sec<><5w<>
Mini Series 2-WAY MOTORIZED VALVE M01 (two wires and reverse polarity)
Voltage: DC6V/12V
1. Connecting SW to OPEN, the valve opens, getting the position, automatically power off, the valve remain fully open position. 2.Connection SW to CLOSE, the valve closes, getting the positio/n, automatically power off, the valve remains side passes position (fully closed).
M02 (three wires two point control)
Voltage: DC6V/12V/ 9-35V
1.Connecting SW to OPEN, the valve opens, getting the position, automatically power off, the valve remain fully open position.
2.Connection SW to CLOSE, the valve closes , getting the position, automatically power off, the valve remains side passes position(fully closed).
M03 (three wires one control)
Voltage: DC6V/9-35V AC/DC9-24V
1.Connecting SW, the valve opens, getting the position, automatically power off, the valve remain fully open position.
2.Disconnecting SW, the valve close, getting the position, automatically power off, the valve remains side passes position(fully
M04 (two wires and fail-safe/power-off return)
Voltage: DC6V/9-35V AC/DC9-24V
1.SW connecting, the valve open, getting the position and the power off automatically, the valve remains fully open/close position.
2.SW disconnecting, the valve close, getting the position and power off automatically, the valve remains fully open/close position.
M05 (five wires with signal feedback and Internal automatic power off function) Voltage: DC6V/12V
1.RD connect with positive, the BK connect with negative, the valve open, the actuator automatically power off after in place .
2.BK connect with positive, the RD connect with negative, the valve close, the actuator automatically power off after in place .
3.YW & WT are connect when the valve open fully, GR & WT are connect when the valve closed fully.
M06 (six wires with signal feedback and two point control)
Voltage: DC6V/12V
1.RD & GR connect with positive, the BK connect with negative.
2. When RD & SW connected, the valve open, the actuator automatically power off after the valve fully open.
3. When GR & SW connected, the valve closed, the actuator automatically power off after the valve fully closed.
4. YW & WT connect with the valve's fully open signal wiring.
5. BL & WT connect with the valve's fully closed signal wiring.
M07 (six wires with signal feedback and one point control) Voltage: DC6V/12V/ 9-35V
- RD connect with positive, GR connect with SW and negative wiring, BK connect with negative wiring.
- SW open, the valve open, and keeping fully open. SW closed, the valve closed, and keeping fully closed.
3.YW & GY connect with the valve's fully open signal wiring. BL & WT connect with the valve's fully closed signal wiring.
M08 (five wires with signal feedback and fail-safe/power-off return function) Voltage: DC6V/9-35V AC/DC9-24V
1.SW connecting, the valve open, getting the position and the power off automatically, the valve remains fully open/close position.
2.SW disconnecting, the valve close, getting the position and power off automatically, the valve remains fully open/close position.
3.YW & GY connect with the valve's fully open signal wiring. BL & WT connect with the valve's fully closed signal wiring.
Related Products
About us
Unique FAQs
1.Can valve electric actuators be retrofitted to existing systems?
Yes, in many cases, valve electric actuators are designed to be retrofit-friendly. However, it's crucial to consider compatibility, sizing, and potential modifications to ensure a seamless integration into existing systems. Consulting with manufacturers and industry experts can provide guidance on retrofitting options.
2.What role do valve electric actuators play in preventing leaks and spills in industrial processes?
Valve electric actuators, with their precise control capabilities, play a crucial role in preventing leaks and spills. By swiftly and accurately modulating valve positions, these actuators contribute to the overall safety and integrity of industrial processes, reducing the risk of environmental incidents.
3.Are there advancements in remote monitoring and control of valve electric actuators?
Yes, advancements in communication technologies have facilitated remote monitoring and control of valve electric actuators. Smart actuators, equipped with connectivity features, allow operators to monitor and adjust valve positions remotely, enhancing operational flexibility and efficiency.
4.How do valve electric actuators contribute to process optimization in manufacturing plants?
Valve electric actuators contribute to process optimization by providing precise control over fluid flow. This level of control enhances the overall efficiency of manufacturing processes, ensuring consistent quality and minimizing wastage.
5.What measures are in place to ensure the cybersecurity of smart valve electric actuators?
As smart technologies become more prevalent, ensuring the cybersecurity of valve electric actuators is paramount. Manufacturers implement robust security measures, including encryption and authentication protocols, to safeguard against cyber threats and unauthorized access.
Contact Us
Want More Infomation About Quarter-Turn Electric Actuator?
Inquiry Us To Get A Best Price!