Only need to connect the heating circulator with the heating oil inlet and outlet of the reactor, from the top of the heater liquid feeding port and add in the heat transfer fluid, turn on add liquid button can easily remove the air in the system, set the temperature requirements , the system can run automatically. The heat transfer medium in a closed system ,with expansion container, the liquid in the expansion tank not participate in the circulation system , either high or low temperature , expansion tank temperature is from room temperature to 50C, can reduce the risk of heat absorption of moisture and volatile in the operation. In case of no changing the heat transfer medium , can be covered room temperature to 200 degree C or 300 degree C .
1. HR series of products can be carried out continuous heating from room temperature to 300 degrees.
2. The circulation pipeline is enclosed, high temperature without volatile oil mist, oil will not be oxidation and browning.
Model | HR-2035W | HR-2050W | HR-2100W | HR-2150W | HR-2200W | HR-2250W | |
Temperature range ºC | RT~200ºC | RT~200ºC | RT~200ºC | RT~200ºC | RT~200ºC | RT~200ºC | |
Controller | PID adaptive controller | ||||||
Temp. control | Heat-conducting medium outlet temp. control | ||||||
Communication protocol | MODBUS RTU Protocol, RS 485 Interface | ||||||
Temperature feedback | Heat-conducting medium temperature feedback PT100 | ||||||
Temp. accuracy | ±0.5ºC | ±0.5ºC | ±0.5ºC | ±0.5ºC | ±0.5ºC | ±0.5ºC | |
Heating power | 3.5kW | 5.5kW | 10kW | 15kW | 20kW | 25kW | |
Cooling capacity | 200ºC | 2.5kW | 5.5kW | 10kW | 15kW | 10kW | 25kW |
100ºC | 1.5kW | 5kW | 10kW | 15kW | 10kW | 20kW | |
50ºC | 0.5kW | 0.8kW | 1.2kW | 2.5kW | 10kW | 5.5kW | |
Circulation pump | Max20L/min 0.8BAR | Max25L/min 1BAR | Max35L/min 1.5BAR | Max50L/min 2BAR | Max80L/min 2BAR | Max110L/min 2BAR | |
Evaporator | Plate heat exchanger | ||||||
Operation panel | Display setting temperature and testing temperature; Touch key display | ||||||
Safetyprotection | Self-diagnosis function; freezer overload protection; high pressure switch, overload relay, thermal protection device, liquid low level protection, high temperature protection and temperature fault protection. | ||||||
Closed circulation system | The whole system is full closed circulation, there is no oil mist at high temperature and no water vapor at low temperature, pressure do not rise up when system is running. The system will supplement oil automatically at low temperature. | ||||||
Connection size | DN-15 | DN15 | DN20 | DN20 | DN20 | DN-20 | |
Connection size (Water-cooled) | 500*680*1350 | 550*680*1350 | 550*680*1450 | 620*680*1550 | 620*680*1550 | 750*750*1750 | |
Weight (Water-cooled) | 160kg | 185kg | 210kg | 255kg | 300kg | 340kg | |
Power | AC 220V 50HZ 4.5kW (max) | AC 380V 50HZ 6.5kW (max) | AC 380V 50HZ 9kW (max) | AC 380V 50HZ 12.5kW (max) | AC 380V 50HZ 16.5kW (max) | AC 380V 50HZ 24kW (max) | |
Case material | Cold rolled steel | ||||||
Optional | Optional 7-inch color touch screen controller, temperature curve record, data export to excel format. | ||||||
Optional | SUS304 case material | ||||||
Optional power | 220V 60HZ three-phase, 440V~480V 60HZ three-phase |
Delivery terms: 10-25days of chillers, heaters only need to take 10-15days to finish them .
Trade terms: EXW , FOB , CIF , CFR, CIP, DDU, DDP ,ETC
Payment terms: T/T or L/C