KWT1C80 series is a typical column double-flange load cell. It adopts the strain princple of column structure, which meets the requirement of hollow structure. And when it measures a larger load, there is a smaller displacement that suitable for dynamic measurement.
The load cell is made of 17-4PH stainless steel, and the shell of it is made of anodic aluminum oxide, which has a good protective effect on the electronic components inside the sensor.
It also has a wide range at 25kN can be choosen to meet different measruement requirements.
Parameter | Unit | Model |
KWT1C80-25K | ||
Range | KN | 25 |
Diameter | mm | 80 |
Height | mm | 60 |
Weight | kg | 0.8 |
Sensitivity | mV/V | 1.0±1% |
Repeatability | %FS | ≤±0.05 |
linearity | %FS | ≤±0.1 |
Hysteresis | %FS | ≤±0.1 |
Creep | %FS/30min | ≤±0.03 |
Bridge Resistance | Ω | 700±5 |
Output Resistance | Ω | 700±5 |
Insulation Resistance | MΩ/100VDC | ≥5000 |
Power Voltage | VDC | 5~12 |
Temperature Compensation | ºC | 0~60 |
Working Temperature | ºC | -10~80 |
Safety Overload | %FS | 150 |
Limited Overload | %FS | 200 |
Cable Size | mm | Φ3×3000 |
Material | High Strength Alloy Steel/Stainless Steel | |
Protection Level | IP64 |
Type | Mounting Hole A | Mounting Hole B | ||||
A1 | Quantity | A2 | B1 | Quantity | B2 | |
KWT1C80-25K | M6 | 4 | 45° | M6 | 4 | 45° |
KWT1C80-50K | M6 | 8 | 45° | M6 | 8 | 22.5° |
KWT1C130-100K | M8 | 8 | 45° | M8 | 8 | 45° |
Type | Size | ||||||||
D1 | D2 | D3 | D4 | D5 | D6 | H1 | H2 | H3 | |
KWT1C80-25K | 80 | 47 | 39 | 68 | 53 | 63 | 14.5 | 5 | 60 |
KWT1C80-50K | 80 | 47 | 42 | 68 | 53 | 64 | 14.5 | 5 | 76 |
KWT1C130-100K | 130 | 80 | 76 | 115 | 94 | 104 | 16.5 | 5 | 100 |
How to choose a proper sensor?
Items | |||
Measuring Items | F&T of 3 Directions | F or T of 3 Directions | F or T of 1 Direction |
No. of Outputs | 6 | 3 | 1 |
Point of F | Not Fixed | Fixed | Fixed |
Direction of F | Not Fixed | Not Fixed | Fixed |
Measuring Accuracy | High | High or Medium | High or Medium |
Budget | High | Medium | Low |
Recommendation | 6 Axis F&T Sensor | 3 Axis F/T Sensor | 1 Axis F/T Sensor |
Note:F stands for force,T stands for torque.
1.How to place an order ?
Just provide us your application&requirement and we`ll help you confirm all the details.
2.What is lead time?
3-5 working days if we have in stock;7-30 working days for bulk order.
3. What is the MOQ?
1 pc for testing is available for all types.
4.Can you provide customized product?
Of course and we can provide whole set solutions for you.
5.What is after-sale service?
Our R&D team will solve all your problems all the way since you get our product.