R290 DC Inverter Air to Water heater Monoblock Heat Pump Heating Cooling

Min.Order: 5
Product origin: Zhongshan, Guangdong, China
Infringement complaint: complaintComplaint
US$ 2720 ~ 3600

Description

R290 EcoSTAR series- Standard Monoblock

Thanks to the use of R290, Amitime heatSTAR+ series (R290) is now not only the best solution for new building, but also possible to fit the retrofit market by lifting up maximum heating temperature to 70C. With good performance in this water temeprature rante, air to water heat pump unit is now possible to be used to replace the old gas/oil boiler without changing the existing heating distribution system, even has old radiators inside.

Amitime's EcoSTAR system has been developed with the idea in mind for maximum possible energy saving, through its ultra high scope rating and quiet operation. Latest development in DC inverter technologies and their application in various internal components including compressor, fan, and water pump, has been the major player in the success of our EcoSTAR line.
 

Technical

 

Model EcoSTAR04MEcoSTAR06MEcoSTAR09MEcoSTAR12MEcoSTAR15M
Power Supply / RefrigerantV/Hz/Ph220-240/50/1 - R290220-240/50/1 - R290220-240/50/1 - R290220-240/50/1 - R290380-415/50/3 - R290
Max. Heating Capacity (1)kW6.20 6.70 9.512.0 16.5
C.O.P (1)W/W4.574.444.553.92 3.98
Heating Capacity Min./Max.(1)kW2.5/ 6.23.1/ 6.73.1 / 9.53.8 / 125.6/16.5
Heating Power Input Min./Max.(1)W500 / 1360680/ 1500585/ 2089900 / 30651120/4170
C.O.P Min./Max.(1)W/W4.57/4.994.44/ 4.834.55 / 5.13.92/ 4.83.98/5.05
Max. Heating Capacity(2)kW5.86.591115.5
C.O.P (2)W/W3.683.623.753.283.25
Heating Capacity Min./Max.(2)kW2.2 /5.83.0 /6.52.7 /9.03.7/ 11.05.3/15.5
Heating power input Min./Max.(2)W600 /1600600 /1800725 / 24001100 / 33501370/4770
C.O.P Min./Max.(2)W/W3.6 / 3.853.62 / 3.863.75 / 4.03.28/3.73.25/3.85
Max. Cooling Capacity (3)kW5.45.5810.2 13.2
E.E.R (3)W/W4.114.133.83.63.65
Cooling Capacity Min./Max.(3)kW2.8 / 5.42.4/ 5.42.4 / 8.05.0/10.26.9/13.2
Cooling Power Input Min./Max.(3)W500 / 1300510 / 1300765 / 21001400/28401540/3650
E.E.R Min./Max.(3)W/W4.11/ 5.394.1/ 4.233.80 / 4.03.6/3.93.65/4.4
Max. Cooling Capacity (4)kW3.53.767.510.1
E.E.R (4)W/W2.89 2.86 2.90 2.752.85
Cooling Capacity Min./Max.(4)kW0.8 /3.51.3 /3.71.8 /6.03.6/7.54.8/10.1
Cooling Power Input Min./Max.(4)W500 /1200470 /1260720 /19451330/27401550/3540
E.E.R Min./Max.(4)W/W1.54/ 2.972.63/ 2.952.9 / 3.052.75/2.902.85/3.05
Circuit BreakerA1616163225
Workable Ambient Temperature RangeºC-25~45-25~45-25~45-25~45-25~45
Max. System Water Temperature (Heating / Cooling)ºC70/2070/2070/2070/2070/20
Min. System Water Temperature (Heating / Cooling)ºC20 / 720 / 720 / 720 / 720 / 7
Max. Operation High PressureMPa3.103.103.103.103.10
Max. Operation Low PressureMPa0.820.820.820.820.82
CompressorType - Quantity/System Twin Rotary - 1Twin Rotary - 1Twin Rotary - 1Twin Rotary - 1Twin Rotary - 1
RefrigerantType / Amount- / kgR290 / 0.45kgR290 / 0.6kgR290 / 0.7kgR290 /0.9kgR290 / 1.5kg
FanQuantity 11112
Airflowm3/h28503150315033006300
Rated powerW62626262124
Noise Level (sound power)Indoor/OutdoordB(A)-/5033/5433/54 34/5637/56
Water Side Heat ExchangerType Plate Heat ExchangerPlate Heat ExchangerPlate Heat ExchangerPlate Heat ExchangerPlate Heat Exchanger
Water Pressure DropkPa2323232323
Piping ConnectionInchG1"G1"G1"G1"G1-1/4"
Allowable Water FlowMin./Rated./Max.L/S0.21/0.29/0.350.21/0.29/0.350.26/0.39/0.460.34/0.57/0.680.5/0.72/0.86
Net Dimension(L×D×H)Indoor Unitmm570x550x260570x550x260570x550x260570x550x260570x550x260
Net Dimension(L×D×H)Outdoor Unitmm1010x370x7001165x370x8501165x370x8501165x370x9501085x390x1450
Net WeightIndoor Unitkg2525252525
Net WeightOutdoor Unitkg739098110145
Note:
(1) Heating condition: water inlet/outlet temperature: 30 °C/35°C, Ambient temperature: DB 7 °C /WB 6 °C;
(2) Heating condition: water inlet/outlet temperature: 40°C/45°C, Ambient temperature: DB 7 °C /WB 6 °C;
(3) Cooling condition: water inlet/outlet temperature: 23 °C/18°C, Ambient temperature: DB 35 °C /WB 24 °C;
(4) Cooling condition: water inlet/outlet temperature: 12°C/7°C, Ambient temperature: DB 35 °C /WB 24 °C; (5) The specifications are subject to change without prior notice. For actual specifications of unit, please refer to the stickers on the unit.




 

Project Cases

 

Certifications

Company Profile

 

Exhibition

 

FAQ

Q: Do you provide OEM & ODM?
A: Yes. We can design products and make logos, labels, cartons, user manuals etc. according to our customer's demand.

Q: What's your MOQ?
A: For official orders, our MOQ is a full container load of 40 feet contaienr.

Q: What's your lead time for orders?
A: Usually 30-35 days. For order of big quantity, to be discussed.

Q: What's your production capacity?
A: We have in total 10 production lines in our factory in Zhongshan now, the production capacity is around 1000 pcs/day.
A new base in Shunde will get ready in 2023 and our production capacity will increase to around 2500 pcs/day.

Q: How can I get the price?
A: We usually quote within 24 hours after we get your inquiry.

Q: What's the payment terms?
A: By T/T, 30% deposit to confirm the order, and the balance to be done before shipment.

Q: How long is your warranty?
A: One year warranty for complete machine, three years warranty for compressor, and long-term technical support.

 
Product Tag:
Related categories:
Scroll to Top