General 1.YCB3000 series frequency converter is a general-purpose high-performance current vector frequency converter, which is mainly used to control and adjust the speed and torque of three-phase AC asynchronous motors. It adopts high performance vector control technology, low-speed and high-torque output, and has the advantages of good dynamic characteristics, super overload capacity, stable performance, powerful protection function, simple human-machine interface, and easy operation. 2.It can be used for driving of weaving, papermaking, wire drawing, machine tool, packaging, food, fan, water pump and various automatic production equipment. |
YCB3000 | - | 4 | T | 0015 | G | |
Name | Power input voltage | Input phase line | Rated power of frequency converter | Load type | ||
YCB3000 | 2:AC220V 4:AC380V | S: Single phase T: Three phase | 0007: 0.75KW 0015: 1.5KW 0022: 2.2KW ...... | G: Constant torque load P: Fan and water pump loads |
Environment | ||||||
Where to use | Indoor, free from direct sunlight, no dust, corrosive gas, combustible gas, oil mist, water steam, dripping water or salt, etc | |||||
Above sea level | Below 1000m, 1% for 100m over 1000m, 1% over 3000m (Note: The highest elecation of 0.4~3kW drive is 2000m, if used above 2000m, please contact the manufacturer) | |||||
Ambient temperature | -10°C~+40°C, when the temperature exceeds 40°C. The decrease is 1.5% per 1C increase, and the maximum ambient temperature is 50°C | |||||
Humidity | Less than 95%RH, no condensation | |||||
Vibrate | Less than 5.9m/s²(0.6g) | |||||
Storage temperature | -20°C~+60°C |
Technical data | ||
Project | Technical specifications | |
Input the frequency resolution | Number setting: 0.01Hz, simulation setting: maximum frequency 0.025% | |
Control method | Open-loop vector control(SVC); closed-loap vector control(FVC); V/F control. | |
Pull-in torque | 0.25Hz/150%(SVC); 0Hz/180%(FVC) | |
Speed range | 1:200 (SVC) | 1:1000 (FVC) |
Steady speeda accuracy | +0.5% (SVC) | +0.02% (FVC) |
Torque control accuracy | FVC: +3%, SVC: 5Hz above +5% | |
Recurrent ascension | Automatic torque increase, manual torque increase of 0.1%-30.0%. | |
V/F curve | Four ways: straight line, multi-point type; complete V y F separation; incomplete V y F separation. | |
Add deceleration curve | Straight-line or S-curve acceleration and deceleration modeFour acceleration and deceleration times, acceleration anddeceleration time range 0.0.6500.0s. | |
DC injection braking | DC brake starting frequency:0.00Hz- maximum frequency; Brake time: 0.0s~36.0s; Brake action current value: 0.0%-100.0% | |
Electronic contro | Tap movementfrequency range: 0.00Hz-50.00Hz;Tap action, acceleration and deceleration time is 0.0s-6500.0s | |
Isimple PLC, multi-segment speedoperation | Up to 16 segments can be run with a built-in PLC or controlterminal. | |
Built-in PID | It can easily realize the process control closed-loop controlsystem. | |
Automatic VoltageAdjustment(AVR) | When the grid voltage changes, the output voltage constant. | |
Over pressure overloss speed control | Automatic limit of current and voltage during operation toprevent frequent excessive flow pressure trip. | |
Quick flow | Minimize the over current fault, and protect the normal | |
Restriction function | operation of the frequency converter. | |
Torque limit andcontrol | The characteristic of "excavator" automatically limits the torqueduring operation to prevent frequent current trip; the vectorcontrol mode can realize torque control. | |
Instantly stop | In case ofinstantaneous power outage, the frequency converteris maintained to reduce the load feedback energy compensationvoltage in a short time. | |
Fast flow limit | Avoid the frequent over current fault of the frequency converter. | |
Invented IO | Five sets of virtual DIDO, which can achieve simple logic control. | |
Timing control | Timing control function: set the time range of 0.0Min ~ 6500.0Mir | |
Multi-motorswitching | Two sets of motor parameters, can realize two motor switchcontrol. | |
Multithreaded bussupport | Support for six fieldbuses: Modbus, Profibus-DP CANlinkCANopen, Profinet, and EtherCAT. | |
Motor overheatingprotection | With the lO extension card 1 option, the analog input Al3 acceptsthe motor temperature sensorinput(PT100, Pt1000). | |
Multi-encodersupport | Support for differential, open-circuit collector, UVW, rotarytransformer,etc |
Project | Technical specifications |
Run instructions | Operation panelgiven, control terminal given, serialcommunication port given.lt can be switched in many ways |
Frequencyinstruction | 10 frequency commands: digital given, analog voltage, analogcurrent, pulse, serial port given. You can be switched in manyways |
Auxiliary frequencyinstruction | 10 Auxiliary frequency commands.It can flexibly realize theauxiliary frequency fine-tuning and frequency synthesis |
Input terminal | standard: Five DI terminals, one of which supports a high-speedpulseinput of up to 100kHz Two Al terminals, 1, one only supports 0 - 10V voltageinput,one supports 0 - 10V voltageinput or 0 -20mAcurrentinput Extended ability: The 5 DI terminals of the One Al terminal, support-10V- 10V,oltage input, and support PT100/ PT1000 support |
leading-outterminal | standard: One high-speed pulse output terminal(optional as theopen-circuit collector type), Support the square-wave signal output of 0 ~ 100kHz 1 DO terminal One relay output terminal One AO terminal with 0 to 20 mA current output or 0 to 10Vvoltage output Extended ability: 1 DO terminal One relay output terminal One AD terminal with 0 to 20 mA current output or 0 to 10Vvoltage output utput |
LED show | Display parameters |
Parameter copy | Quick replication of the parameters is available through theLCD action paneloption |
Key-lock andfunctionselection | Part or all of the keys can be locked to define the scope ofsome keys to prevent misoperation |
Lack ofphaseprotection | Input phase protection, output phase phase protection |
Instant over currentprotection | Stop at over 250%% ofthe rated output current |
Over voltagecrowbar | Stop when the main circuit DC current is above 820V |
Under voltageprotection | Stop when the main circuit DC currentis below 350V |
Overheat protection | Protection is triggered when the inverter bridge overheated |
Overload protection | 150%rated current for 60s shutdown (4T4500G: 130% ratedcurrent running for 60s shutdown) |
Over currentpratection | Stop protection exceeding 2.5 times rated current |
Brake protection | Brake unit overload protection, brake resistance short-circuitprotection |
short-circuitprotection | Dutput alternate with short circuit protection, output shortcircuit to ground pratection |
Model | Power supply capacity is KVA | Input current A | Output current A | Adaptation motor | |
KW | HP | ||||
Single-phase power supply: 220v (-10%~+15%), 50/60Hz | |||||
YCB3000-2S0007G | 1.5 | 8.2 | 4.0 | 0.75 | 1 |
YCB3000-2S0015G | 3.0 | 14 | 7.0 | 1.5 | 2 |
YCB3000-2S0022G | 4.0 | 23 | 9.6 | 2.2 | 3 |
YCB3000-2S0040G | 8.9 | 14.6 | 13 | 4.0 | 5 |
YCB3000-2S0055G | 17 | 26 | 25 | 5.5 | 7.5 |
Three-phase power supply: 220V (-10%~+15%), 50/60Hz | |||||
YCB3000-2T0007G | 3 | 5 | 3.8 | 0.75 | 1 |
YCB3000-2T0015G | 4 | 5.8 | 5.1 | 1.5 | 2 |
YCB3000-2T0022G | 5.9 | 10.5 | 9 | 2.2 | 3 |
YCB3000-2T0040G | 8.9 | 14.6 | 13 | 4.0 | 5 |
YCB3000-2T0055G | 17 | 26 | 25 | 5.5 | 7.5 |
YCB3000-2T0075G | 21 | 35 | 32 | 7.5 | 10 |
YCB3000-4T0110G | 30 | 46.5 | 45 | 11 | 15 |
YCB3000-4T0150G | 40 | 62 | 60 | 15 | 20 |
YCB3000-4T0185G | 57 | 76 | 75 | 18.5 | 25 |
YCB3000-4T0220G | 69 | 92 | 91 | 22 | 30 |
YCB3000-4T0300G | 85 | 113 | 112 | 30 | 40 |
YCB3000-4T0370G | 114 | 157 | 150 | 37 | 50 |
YCB3000-4T0450G | 135 | 180 | 176 | 45 | 60 |
YCB3000-4T0550G | 161 | 215 | 210 | 55 | 75 |
YCB3000-4T0750G | 236 | 315 | 304 | 75 | 100 |
Model | Power supply capacity is KVA | Input current A | Output current A | Adaptation motor | |
KW | HP | ||||
Three-phase power supply: 380V (-10%~+15%), 50/60Hz | |||||
YCB3000-4T0015G | 3.0 | 5 | 3.8 | 1.5 | 2 |
YCB3000-4T0022G | 4.0 | 5.8 | 5.1 | 2.2 | 3 |
YCB3000-4T0030G | 5.0 | 8.0 | 7.2 | 3.0 | 4 |
YCB3000-4T0040G | 5.9 | 10.5 | 9 | 4.0 | 5 |
YCB3000-4T0055G | 8.9 | 14.6 | 13 | 5.5 | 7.5 |
YCB3000-4T0075G | 11 | 20.5 | 17 | 7.5 | 10 |
YCB3000-4T0110G | 17 | 26 | 25 | 11 | 15 |
YCB3000-4T0150G | 21 | 35 | 32 | 15 | 20 |
YCB3000-4T0185G | 24 | 38.5 | 37 | 18.5 | 25 |
YCB3000-4T0220G | 30 | 46.5 | 45 | 22 | 30 |
YCB3000-4T0300G | 54 | 57 | 60 | 30 | 40 |
YCB3000-4T0370G | 63 | 69 | 75 | 37 | 50 |
YCB3000-4T0450G | 81 | 89 | 91 | 45 | 60 |
YCB3000-4T0550G | 97 | 106 | 112 | 55 | 75 |
YCB3000-4T0750G | 127 | 139 | 150 | 75 | 100 |
YCB3000-4T0900G | 150 | 164 | 176 | 90 | 120 |
YCB3000-4T1100G | 179 | 196 | 210 | 110 | 150 |
YCB3000-4T1320G | 220 | 240 | 253 | 132 | 180 |
YCB3000-4T1600G | 263 | 287 | 304 | 160 | 210 |
YCB3000-4T1850G | 305 | 323 | 340 | 185 | 240 |
YCB3000-4T2000G | 334 | 365 | 377 | 200 | 260 |
YCB3000-4T2200G | 375 | 410 | 426 | 220 | 285 |
YCB3000-4T2500G | 404 | 441 | 465 | 250 | 320 |
Model | Power supply capacity is KVA | Input current A | Output current A | Adaptation motor | |
KW | HP | ||||
Three-phase power supply: 380V (-10%~+15%), 50/60Hz | |||||
YCB3000-4T2800G | 453 | 495 | 520 | 280 | 370 |
YCB3000-4T3150G | 517 | 565 | 585 | 315 | 420 |
YCB3000-4T3550G | 565 | 617 | 650 | 355 | 480 |
YCB3000-4T4000G | 629 | 687 | 725 | 400 | 530 |
YCB3000-4T4500G | 716 | 782 | 820 | 450 | 600 |
YCB3000-4T5000G | 800 | 820 | 900 | 500 | 680 |
YCB3000-4T5600G | 930 | 950 | 1020 | 560 | 750 |
YCB3000-4T6300G | 1050 | 1050 | 1120 | 630 | 850 |
YCB3000-4T7200G | 1200 | 1200 | 1300 | 720 | 960 |
YCB3000-4T8000G | 1330 | 1380 | 1420 | 800 | 1060 |
YCB3000-4T10000G | 1660 | 1650 | 1720 | 1000 | 1330 |
Overall and mounting dimensions(mm) | ||||||
Model | Install the holeposition of mm | External size: mm | Install aperture (mm) | |||
A | B | H | W | D | ||
YCB3000-4T0015G | 79 | 154 | 164 | 89 | 125 | Φ4 |
YCB3000-4T0022G | 79 | 154 | 164 | 89 | 125 | Φ4 |
YCB3000-4T0030G | 79 | 154 | 164 | 89 | 125 | Φ4 |
YCB3000-4T0040G | 86 | 173 | 184 | 97 | 145 | Φ5 |
YCB3000-4T0055G | 86 | 173 | 184 | 97 | 145 | Φ5 |
YCB3000-4T0075G | 131 | 245 | 257 | 146.5 | 185 | Φ6 |
YCB3000-4T0110G | 131 | 245 | 257 | 146.5 | 185 | Φ6 |
YCB3000-4T0150G | 131 | 245 | 257 | 146.5 | 185 | Φ6 |
YCB3000-4T0185G | 151 | 303 | 320 | 170 | 205 | Φ6 |
YCB3000-4T0220G | 151 | 303 | 320 | 170 | 205 | Φ6 |
YCB3000-4T0300G | 120 | 385 | 400 | 200 | 220 | Φ7 |
YCB3000-4T0370G | 120 | 385 | 400 | 200 | 220 | Φ7 |
YCB3000-4T0450G | 200 | 493 | 510 | 260 | 252 | Φ7 |
YCB3000-4T0550G | 200 | 493 | 510 | 260 | 252 | Φ7 |
YCB3000-4T0750G | 200 | 493 | 510 | 260 | 252 | Φ7 |
Model | Install the holeposition of mm | External size: mm | Install aperture (mm) | |||
A | B | H | W | D | ||
YCB3000-4T0900G | 200 | 630 | 660 | 320 | 300 | Φ9 |
YCB3000-4T1100G | 200 | 630 | 660 | 320 | 300 | Φ9 |
YCB3000-4T1320G | 250 | 755 | 780 | 400 | 345 | Φ12 |
YCB3000-4T1600G | 250 | 755 | 780 | 400 | 345 | Φ12 |
YCB3000-4T1850G | 250 | 755 | 780 | 400 | 345 | Φ12 |
YCB3000-4T2000G | 300 | 872 | 900 | 460 | 355 | Φ12 |
YCB3000-4T2200G | 300 | 872 | 900 | 460 | 355 | Φ12 |
YCB3000-4T2500G | 360 | 922 | 950 | 500 | 355 | Φ12 |
YCB3000-4T2800G | 360 | 922 | 950 | 500 | 355 | Φ12 |
YCB3000-4T3150G | 500 | 1029 | 1050 | 650 | 365 | Φ12 |
YCB3000-4T3550G | 500 | 1029 | 1050 | 650 | 365 | Φ12 |
YCB3000-4T4000G | 500 | 1265 | 1300 | 650 | 385 | Φ14 |
YCB3000-4T4500G | 500 | 1265 | 1300 | 650 | 385 | Φ14 |
YCB3000-4T5000G | 500 | 1265 | 1300 | 650 | 385 | Φ14 |
YCB3000-4T5600G | 600 | 1415 | 1450 | 850 | 435 | Φ14 |
YCB3000-4T6300G | 600 | 1415 | 1450 | 850 | 435 | Φ14 |
YCB3000-4T7200G | 600 | 1415 | 1450 | 850 | 435 | Φ14 |
YCB3000-4T8000G | 1000 | 1415 | 1450 | 1100 | 465 | Φ14 |
YCB3000-4T10000G | 1000 | 1415 | 1450 | 1100 | 465 | Φ14 |