120L Medical Sterilization Equipment Ethylene Oxide Sterilizer

Min.Order: 1
Product origin: Shanghai, China
Infringement complaint: complaintComplaint
US$ 5500 ~ 5700

Description

Specification
Heating method
Electric heating
Power
3.0KVA
AC.220V, frequency 50Hz
Equipment (Length × Width × Height)
795 × 615× 1140mm
Liner size(Length × Width × Height)
585 × 375 × 472mm
Effective Volume
120L
Weight
147KG
Temperature display
LCD touch screen
Material of Sterilization Room
304 anti-corrosion stainless steel
Outer box material
Carbon steel (thickness 1.8mm) baking powder
Temperature during sterilization
50 ºC
Working pressure
-60kpa
Highest anti-stress value
-80kpa
Humidity during sterilization
45% -75%
Selected gas
Pure ethylene oxide gas
Sterilization time
0-99 hours adjustable
Vacuum speed
15 minutes to pump to -60kpa
Air Replacement
Automatic ventilation, 5 cycles of ventilation, every 15 minutes
Full-automatic control system
One-click start to end, the whole process is automatically completed
Display status
Display operating status, temperature, humidity, pressure, sterilization time, residual gas treatment time, times, steam generator temperature.
Printer
Use a micro printer to print out the data every minute during the entire sterilization process, which can be stored permanently.
Humidity Sensor
The built-in humidity sensor automatically detects the humidity in the cavity.
Pressure Sensor
The built-in pressure sensor automatically detects the pressure in the cavity.
Temperature Sensor
The built-in temperature sensor automatically detects the temperature in the cavity, the accurate range is 50 ºC ± 3 ºC.
Sealed door
Using 5052 high-quality aviation aluminum, thickness ≥15mm, pressure resistance 200Kpa.
Humidification System
Pulse humidification under vacuum.
Residual gas treatment device
The filtration rate of the filter to the particle diameter ≥0.3μm is not less than 99.5%.
Leakage rate of sterilization chamber
The measurement of the leakage rate is carried out under the conditions of no load, the temperature of the sterilization chamber is unchanged, the test pressure is -50kPa, and the measurement time is 1h. The average leakage rate within the measurement time is ≤0.1kPa/min.
Vacuum rate
Under no-load conditions, the time for the sterilizer to vacuum from atmospheric pressure to -60kPa should be ≤30min.
Automatic dosing
Built-in piercing technology in the sterilization chamber.
Automatic memory recovery function
When the power is cut off unexpectedly, the sterilizer will automatically remember the state when it is stopped.
Heating system
Use explosion-proof electric heating device.
Various protection functions
With over-voltage and over-temperature protection function, it is safer and more reliable.
Alarm system
There are high temperature alarm system, ultra-low pressure alarm system.
Power-off memory function
If the power is cut off during the sterilization process, the screen will prompt "Yes" and "No" to continue the previous operation after the power is turned on again. At this time, you can select "Yes" to continue the last run. You can also choose "No" to cancel the operation.

 